HBM ML71BS6 User manual

A0851-3.1 en
MGCplus Measuring
amplifier system
CAN bus interface
ML71BS6
Operating manual


3
MGCplus−ML71BS6
A0851-3.1 de HBM
Contents Page
Safety instructions 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Introduction 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Connections 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Pin assignment 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Front panel 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Parameterization 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 Settings CAN1 /CAN2 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.1 Panel output signals CAN 1 11. . . . . . . . . . . . . . . . . . . . . .
5 Menu structure in set-up mode 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 CAN protocol 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 Measurement signal transmission 14. . . . . . . . . . . . . . . . . . . . . . . . .
6.1.1 Absolute values in Float 14. . . . . . . . . . . . . . . . . . . . . . . . .
6.1.2 In digits as Long 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1.3 In digits as Word 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1.4 Identifier assignment 14. . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Specifications 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4
MGCplus−ML71BS
6
A0851-3.1 enHBM
Safety instructions
Use in accordance with the regulations
The ML71BS6 CAN bus module is to be used exclusively for measurement
tasks and directly related control tasks. Use for any purpose other than the
above shall be deemed to be not in accordance with the regulations.
To ensure safe operation, the device may only be operated in accordance with
the information given in the Operating Manual. It is also essential to comply
with the legal and safety requirements for the application concerned during
use. The same applies to the use of accessories.
General dangers of failing to follow the safety instructions
The ML71BS6 CAN bus module complies with the state of the art and is
fail-safe. The device may give rise to further dangers if it is inappropriately
installed and operated by untrained personnel.
Any person instructed to carry out installation, commissioning, maintenance or
repair of the device must have read and understood the Operating Manual
and in particular the technical safety instructions.
Remaining dangers
The scope of performance and supply of the ML71BS6 only covers part of the
range of measurement technology. In addition, equipment planners, installers
and operators should plan, implement and respond to the safety engineering
considerations of measurement technique in such a way as to minimise
remaining dangers. Prevailing regulations must be complied with at all times.
There must be reference to the remaining dangers connected with
measurement technique.
In this manual, the following symbols are used to draw your attention to any
remaining dangers that might occur when working with the ML71BS6:
Symbol: WARNING
Meaning: Dangerous situation
Warns of a potentially dangerous situation in which failure to comply with
safety requirements can lead to death or serious physical injury.

5
MGCplus−ML71BS6
A0851-3.1 en HBM
Symbol:
Meaning: CE mark
The CE mark enables the manufacturer to guarantee that the product com-
plies with the requirements of the relevant EC directives (the declaration of
conformity is available at http://www.hbm.com/HBMdoc).
Working safely
Error messages must only be acknowledged when the cause of the error has
been removed and no further danger exists.
The device complies with the safety requirements of DIN EN 61010-Part 1
(VDE 0411-Part 1); Protection Class I.
To ensure adequate immunity from interference, use only Greenline shielded
ducting (see HBM offprint ”Greenline shielding design, EMC-compliant mea-
suring cable; G36.35.0)
Conversions and modifications
No modifications that affect the design or the technical safety of the ML71BS6
CAN bus module may be carried out without our express agreement. Any
modification shall exclude all liability on our part for any resulting damage.
In particular any repair or soldering work on motherboards is prohibited. When
exchanging complete modules, use only original parts from HBM.
Qualified personnel
This instrument must only to be installed and used by qualified personnel,
strictly in accordance with the technical data and the safety requirements and
regulations listed. It is also essential to comply with the legal and safety
requirements for the application concerned during use. The same applies to
the use of accessories.
Qualified personnel means persons entrusted with the installation, assembly,
commissioning and operation of the product who possess the appropriate
qualifications for their function.
Maintenance and repair work on an open device with the power on must only
be carried out by trained personnel who are aware of the danger involved.

6
MGCplus−ML71BS
6
A0851-3.1 enHBM
1 Introduction
The ML71BS6 is an MGCplus system module that takes measurement data
from the MGC and outputs it as CAN messages. It records up to 128
measured values per CAN port, scales them and outputs them at the CAN
bus.
Two independent CAN interfaces per channel and two different physical layers
(ISO 11898−24V and a ”low-speed” link based on the Philips TJA1053
transceiver module) are supported.
The measurement data to be transmitted can be selected either by using the
AB22A/AB32 display and control panel or by using the “MGCplus Assistant”
software from HBM.

7
MGCplus−ML71BS6
A0851-3.1 en HBM
2 Connections
WARNING
Before starting the device, read the safety instructions.
2.1 Pin assignment
The CAN bus is connected to the AP71 connection board by a 9-pin Sub-D
connector. You can connect two independent CAN field bus systems (female
connectors CAN1 and CAN2). Both the CAN interfaces are used to output the
MGCplus measurement data. Each of the interfaces can be assigned up to
128 measured values.
Connectors (male)
CAN1/CAN2
1
5
6
9
CAN Shield
CAN_GND
CAN_L CAN_H
GND
CAN_V+
Physical layer:
High: Standard CAN speeds up to 1MBaud acc. to ISO11898
(24 V dielectric strength).
Low: Low−speed bus for in-car communication up to 100 kBaud
(CAN_V+ must be connected to 12 V)
Fig. 2.1: CAN connection

ML71
BS6
8
MGCplus−ML71BS
6
A0851-3.1 enHBM
3 Front panel
The front panel LEDs have a dual function:
In Level mode, the signal level at the analogue output is displayed.
In Status mode, the LEDs are assigned as shown below:
LED caption Colour Meaning in Status mode
CHAN. yellow Channel selected
ERROR/WARN. red error/warning
Rx1 − not used
Tx1/OVRN1 red/yel-
low CAN protocol transmitted
BUSERR1 red Bus error at CAN1
Rx2 yellow not used
Tx2/OVRN2 red/yel-
low CAN protocol transmitted
BUSERR2 red Bus error at CAN2
Analog output (BNC connector (female))
Any voltage from −10 V to +10 V can be output through the
female BNC connector by interface command.

9
MGCplus−ML71BS6
A0851-3.1 en HBM
4 Parameterization
4.1 Settings CAN1 /CAN2
The baud rate, the transmission formats, the number of signals and the output
rate of the 1st CAN bus are set here. The same menu is applied
correspondingly to the 2nd CAN bus.
The maximum number of signals for a bus is 128 signals.
The following output rates are offered for selection depending on the number
of output signals. In the case of the 2nd CAN port, please note that the
maximum possible output rates can only be achieved if no signals have been
selected at CAN port1.
If a selected rate cannot be achieved, the messages will be output as quickly
as possible and an error message will be generated. Transmission will then
not be at a fixed frequency.
Number of signals
Format
Output rate [Hz]
CAN1 CAN2
Format
Port1 Port2
4 4 INT16 2400 800
4 4 INT32 2400 600
4 4 Float32 2400 400
8 8 INT16 1200 800
8 8 INT32 1200 400
8 8 Float32 1200 300
16 16 INT16 600 600
16 16 INT32 600 300
16 16 Float32 600 300
The first ID of a range can be set. The last ID is derived from this and from the
number of signals.

10
MGCplus−ML71BS
6
A0851-3.1 enHBM
1 Use the shift key to change to set-up mode and then press the
function key . Use the cursor keys to select “Settings CAN1” and
confirm with .
Settings CAN1 CHANNEL3
1000 kBaud
System Display Parameters Options
Float
8
1200 1/2
Baud rate
Format
Number of signals
Output rate
ID range used
1000 kBaud
500 kBaud
.
.
10 kBaud
Float
32−bit integers
16−bit integers
1 1/s
10 1/s
.
.
1200 1/s
First ID
Last ID
Reset CAN1 port
640
641
Fig. 4.1: CAN1 / CAN2 dialogue window
2 Use the cursor keys to choose the baud rate selection field. Use to
call the selection list and choose the desired baud rate. Confirm with .
3 Select the output rate in the same way as for 2.
4 Use the cursor keys to select the “Number of signals” edit field and
enter the desired figure.
5 Select the output rate in the same way as for 2.
6 Use the cursor keys to select the “First ID” edit field and enter the
desired figure. The “Last ID” edit field is set automatically.
7 Use the shift key to change to measuring mode and confirm the
follow-up question with .