Haswill AL8010F+ User manual

www.thermo-hygro.com
User’sManualofAL8010F+
Heating or Cooling Controller (TC2-1412-1006)
1. Features
Within adjustable Aim Temperature Value, Temp. Difference Value, Compressor Delay
Time, calibration value and Upper and Lower temperature setting limit.
It will change the room temperature by turn on / off the load automatically.
Auto memory exist data if electric off, need not to configure it again once power back.
With 0.1°C precision and ±1.0°C accuracy;
Different vividly icon indicatorsfor freezing and heating mode easy to distinguish working
mode and save time compare to similar controller from other suppliers.
Alarm once room temperature exceed the measureable temperature limit.
2. Application
Suit to refrigeration, deep freeze, seafood machine, water heater and other occasions where needs
basically function of temperature control.
3. Package
Controller
1PCS
Fasteners
2PCS
Sensor
1PCS
Manual
1PCS
Waterproof Cover
1PCS
4. Specification
Input Power
220VAC ± 10% 50/60HZ; (12V/24/110V Option)
Maximum current
10A (Default) under 220V AC
Sensor
NTC, 25°C /10 KΩ, sensor cable 200cm
Protection Class
IP65 to front panel
Storage
-10°C ~ 60°C, RH<90%, without condensation
Meas. & Control:
-40°C ~ +110°C
Precision:
0.1°C
Accuracy:
± 1°C
Rated Power:
≤ 5W
5. Environmental Information
Package:
The packages material is 100% recyclable. Just dispose it through
specialized recyclers.
Product:
The electro components can be recycled or reused if it is disassembled
for specialized companies.
Disposal:
Please do not burn or throw the controllers in domestic garbage,
observe the respectively law in your region concerning the
environmental responsible manner of dispose its devices.
6. Interface & Operation
6.1. Front Panel & Icon
Under normal status
When screen light, Press and hold on
3s to turn off the display, attention it is just
dim the screen not turn off controller;
When screen dark, Press and release, to
light on the screen.
Indicator / Character in Display
Indicator
Meaning On Hide Wink
Temp. Alarm
Abnormal
Normal
Sensor Error
Cooling Status
Working
Not Working
N/A
Heating Status
Working
Not Working
N/A
SET
Setting Status
N/A
Normal mode
In setting mode
6.2. Dimensions & Installation
A. Suggested amount dimension: 71.0*29.0*85.0mm (W*H*D)
B. Detach the slide fasteners, put the controller into the hole, wiring follow diagram;
C. Install the fasteners, and install the waterproof cover.
D. Please avoid installing in the below environments:
Relative humidity > 90%, have condensation
The places that temperature <-10°C or >60°C;
The places that have inflammables and explosives;
Strong vibration or struck
Exposed to the continuous water mist spraying;
Exposed to the dust;
Exposure to corrosive and pollution gas (for example:the gas, smoke or salt
fog that contain sulfur or ammonia;
Wireless electromagnetic interference or strong magnetic fields (near to
transmitting antenna or switch board room);
1 / 2

www.thermo-hygro.com
6.3. Wiring Diagram
A. 10K NTC sensor, Need not to distinguish + or - when wiring it.
B. The input voltage must within marked voltage ±10% value in diagram.
C. Load Power ≤Voltage of load ∗Max current of Relay
Factor
The factor for Inductive Load like compressor, heating pump, usually be 5~8;
The factor for Resistive Load like Electric heating rod, electric blanket, fan
usually is 1.5 ~ 2;
The Factor for Incandescent lamp usually is 15.
7. Configurations
7.1. Code and Function Menu
Code Function Min. Max. Default Step
HC Heating or Cooling C. H. C.
PT Delay Time (Min) 0 7.0 1.0 1.0
CA
Temperature Calibration (°C)
-7.0
7.0
0
0.1
HS
Upper Limit (°C) ATV
110.0
110.0
1.0
LS Lower Limit (°C) -40.0 ATV
-40.0 1.0
D Return Differential (°C) 1.0 15.0 5.0 1.0
7.2. What is ATV and how to set it?
ATV means Aim Temperature Value which is the ideal temperature value you wish to reach, once
exceed this value (if difference value = 0) the status of load will be changed, details of setting
ATV as follow
Step1 Assure power on, Press and release key once times you will find display blink a
data which is changeable.
Step2 Now press the or keys to get you aim value;
press and hold on the or is fast forward function;
the steps length is 0.1°C;
The editable range between lower (LS) and Upper (HS) limit, attention HS&
LS are only the limit for ATV setting not as the point to trigger alarm.
Step3
Waiting for 5s the device will save data automatically or press to save it.
7.3. When will the load working?
Firstly of all, the instant time passed the delay time (PT), and then matches one of the following
A. In heating mode (
HC
=
C
), the relay will turn on heater when
Measured Temperature Value ≤ATV - Temp. Return Differential (D)
B. In cooling mode (
HC
=
H
), the relay will turn on cooler
Measured Temperature Value ≥ATV +Temp. Return Differential (D)
7.4. How to correct measured temperature if found it not right?
Exist gap/distance between the measured temperature and the real temperature is normal
especially the first time launch this controller; the gaps could be corrected by setting the value in
CA, and please follows the formula: CA= Real Temperature-Measured Temperature.
7.5. How to set other parameters?
Step1
Press and hold on until appears the code HC (nearly 3s).
Step2
Now press the or keys to select the code you want to update;
Step3
Press and release to see exist value; then press or to get your aim value;
Step4
Press key to memorize the configured value and return to the menu.
Repeat operation from Step2 / 3 / 4 to adjust other parameters;
Step5
P
ress to save data and quit from setting mode back to normal monitor status; or let it
alone, the modified value will be saved automatically if without operation in 15s.
8. Error & Solution
When alarm occur, you will find flashing in screen and buzzer screams,
Code Reason Solution
EE.E Circuit of sensor short or open Fix it or replace a sensor.
Room Temperature >120°C or
Room Temperature < -20°C
Check the room temperature where the
sensor is placed,
and then change the
working status of load
manually if
necessary.
EE.H
120°C > Room temperature > 100°C
EE.L -20°C < Room temperature < -10°C
Tip:
A. EE.H or EE.Lwill flashing in display with instant temperature alternately each 2s.
B. EE.H & EE.L allow stopping the buzzer scream by press any key, but EE.E doesn’t.
XUZHOU HASWILL ELECTRONICS CO., LTD.
www.thermo-hygro.com ; tech@thermo-hygro.com
Copyright 2016 Haswill-Haswell All Rights Reserved
2 / 2
Other Haswill Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

SMC Networks
SMC Networks Thermo-con INR-244-639 Operation manual

eltherm
eltherm Ex-TC It Series operating instructions

Omron
Omron C200H-TV Series Operation manual

industrie technik
industrie technik CA1 instructions

KRAL
KRAL EET 32 operating instructions

dixell
dixell XR420C Installing and operating instructions