Hama TS34A User manual

00186345
00176931
TS34A
Outdoor Sensor
Außensensor
E
CZ
F
D
GB
I
P
NL
GR
RO
H
FIN
BG
PL
S
RUS
SK
Használati útmutató
Návod kpoužití
Návod na použitie
Manual de instruções
Manual de utilizare
Bruksanvisning
Käyttöohje
Работна инструкция
Operating Instructions
Bedienungsanleitung
Mode d‘emploi
Instrucciones de uso
Руководство по эксплуатации
Istruzioni perl‘uso
Gebruiksaanwijzing
Οδηγίεςχρήσης
Instrukcja obsługi

2
3
4
25
43
.5
1
%
REMOTE SENSOR
RF WIRELESS
°C
Ch
1
5

2
GOperating instruction
Controls and Displays
AMeasuring station
1. LED indicator
2. Battery compartment
3. CHANNEL slide switch =selects channel
4. Recess for wall mounting
5. LCDdisplay
1. Explanation of Warning Symbols and Notes
Warning
This symbol is used to indicate safety instructions or to draw your
attention to specichazards and risks.
Note
This symbol is used to indicate additional information or important
notes.
2. Package Contents
•TS34A Outdoor Sensor
•These operating instructions
3. Safety Notes
•The product is intended for private, non-commercial use only.
•Do not operate the product outside the power limits given in the
specications.
•Do not use the product in moist environments and avoid splashes.
•Do not use the product in the immediate vicinity of heaters or other
heat sources or in direct sunlight.

3
•Do not use the product in areas wherethe use of electronic devices
is not permitted.
•Do not put the product near interference elds, metal frames,
computers, TVs, etc. Electronic devices and window frames can
negatively affect the product’sfunctionality.
•Do not drop the product and do not expose it to any major shocks.
•Do not open the device or continue to operate it if it becomes
damaged.
•Do not attempt to service or repair the product yourself.Leave any and
all service work to qualied experts.
•Keep the packaging material out of the reach of children due to the
risk of suffocation.
•Dispose of packaging material immediately according to locally
applicable regulations.
•Do not modify the product in any way.Doing so voids the warranty.
•Use the product for its intended purpose only.
•Keep this product, as all electrical products, out of the reach of
children!
•Use the item only in moderate climatic conditions.
Warning –Batteries
•When inserting batteries, note the correct polarity (+ and -
markings) and insert the batteries accordingly.Failure to do so
could result in the batteries leaking or exploding.
•Only use batteriest (or rechargeable batteries) that match the
specied type.
•Beforeyou insert the batteries, clean the battery contacts and the
polar contacts.
•Do not allow children to change batteries without supervision.
•Do not mix old and new batteries or batteries of adifferent type
or make.

4
•Remove the batteries from products that arenot being used for
an extended period (unless these arebeing kept ready for an
emergency).
•Do not short-circuit batteries.
•Do not charge batteries.
•Do not throw batteries in a re.
•Keep batteries out of the reach of children.
•Never open, damage or swallow batteries or allow them to enter
the environment. They can contain toxic, environmentally harmful
heavy metals.
•Immediately remove and dispose of dead batteries from the
product.
•Avoid storing, charging or using the device in extreme temperatures
and extremely low atmospheric pressure(for example, at high
altitudes).
4. Getting started
•Unscrew the screws on the battery compartment (2) on the back of the
measuring station and open it.
•Move the CH slide switch (4) to the left or right to select the channel
on which the measuring station transmits.
•Insert two AAA batteries with the correct polarity.
•Then close the battery compartment cover.
Replacing the batteries
•Open the battery compartment (2), remove and properly dispose of
the dead batteries and insert two new AAA batteries with the correct
polarity.Then close the battery compartment cover.
Note
Beforeuse, make surethat you insert the batteries in the measuring
station rst and then in the base station.

5
5. Installation
Note –Installation
•We recommend initially placing the base and measuring stations in
the intended locations without installing them and making all the
settings described in 6. Operation.
•Only install the stations once the appropriate settings have been
made and astable wireless connection is established.
Note –Installation a
•We recommend initially placing the base and measuring stations in
the intended locations without installing them and making all the
settings described in 6. Operation.
•Only install the stations once the appropriate settings have been
made and astable wireless connection is established.
Note
•The wireless transmission range between the measuring and base
stations is up to 30 metres in open spaces.
Beforeinstallation, ensurethat wireless transmission will not be
disrupted by interference or obstacles like buildings, trees, vehicles,
high-voltage lines, etc.
•Beforethe nal installation, ensurethat thereissucient reception
between the intended installation locations.
•When installing the measuring station, ensurethat it is protected
from direct sunlight and rain.
•The international standardheight for measuring air temperatureis
1.25 m(4ft) above ground.

6
Warning
•Buy special or suitable installation material from aspecialised
dealer for wall-mounting.
•Ensurethat no faulty or damaged parts areinstalled.
•Never apply force during installation. This could damage the
product.
•Beforeinstallation, ensurethat the chosen wallissuitable for the
weight to be installation, and make surethat thereare no electrical
wires, water,gas or other lines in the wall at the installation site.
•Do not mount the product above locations wherepersons might
linger.
•Youcan position the measuring station on alevel outdoor surface
using the base.
•We recommend installing the measuring station securely on an
outdoor wall.
•Install an anchor,screw,nail, etc. in the wall of your choice.
•Hang the measuring station using the opening intended for this
purpose (4).
6. Operation
6.1. Connection to the measuring station
•To connect the base station and the measuring station, place the two
devices as close together as possible.
•After you insert the batteries, the base station automatically searches
for aconnection to the measuring station and performs initial setup. If
the device does not connect automatically,the manual search program
on the base station must be started.

7
Note
•Initial setup takes approximately 3minutes.
•During the connection attempt, the radio symbol and the LED
indicator (1) on the measuring station will ash.
•Do not press any buttons during setup. Otherwise, values may
not be transmitted correctly and thereisarisk of value errors and
inaccuracies.
•The setup process is completed when the indoor and outdoor
measurement data is displayed on the base station.
•The measured value is automatically updated by the base device
about every 57 seconds.
6.2. Selecting the channel/Other measuring stations
Note
•Youcan connect up to three different base stations to the measuring
station. Ensurethat the base station and measuring station areset to the
same channel. Suitable base stations can be found at www.hama.com
•The transmission channel on the supplied measuring station can be
changed/set (CH1, CH2, CH3).
•The measuring station is suitable for the following base stations:
76045, 113964, 123126, 123127,123128, 123129, 136256, 136257,
136258, 136259, 186306, 186307, 186308; 186353, 186354,
186417, 186418
6.3. Low battery charge
Note –Replacing the batteries
•Note that the stations have to be resynchronised each time after
you change the batteries in the measuring or base station.
•To do this, remove the batteries from the other station and then
reinsert them, or change them as required.

8
7. Care and Maintenance
•Only clean this product with aslightly damp, lint-free cloth and do not
use aggressive cleaning agents.
•Make surethat water does not get into the product.
8. Warranty Disclaimer
Hama GmbH &CoKG assumes no liability and provides no warranty for
damage resulting from improper installation/mounting, improper use of
the product or from failuretoobserve the operating instructions and/
or safety notes.
9. Technical Data
Measuring station
Power supply 1,5 V
2xAAA batteries
Measuring range
Thermometer
Hygrometer
Barometer
-20°C –+60°C/ -4°F –140°F
20% –95%
Measurement increments
Temperature
Humidity
0,1°C /0,2°F
1%
Measuring cycle
thermometer/hygrometer
Barometer
~57s
-
DCF radio-controlled clock No
Hygrometer Yes
Thermometer Yes

9
Barometer No
Moon phases -
Max. number of measuring stations 3
Frequency 433 MHz
Radio-frequency 0.13 µW
Range ≤30 m
10. Declaration of Conformity
Hereby,Hama GmbH &CoKG declares that the radio
equipment type [00186345, 00176931] is in compliance
with Directive 2014/53/EU.The full text of the EU declaration
of conformity is available at the following internet address:
www.hama.com->00186345, 00176931->Downloads.
Maximum radio-frequency
power transmitted 0,015 mW
Other manuals for TS34A
1
This manual suits for next models
2
Table of contents
Languages:
Other Hama Accessories manuals









































