IMPORTANT SAFETY INSTRUCTIONS
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
• Use indoors only.
• Do not use for any purpose other than described in this user guide.
• Use only manufacturer’s recommended accessories.
• Do not use with damaged cord or plug.
• Never put anything on top of the appliance.
• If appliance is not working as it should, or has been dropped, damaged, le out-
doors, or dropped into water, have it repaired at an authorized service center.
• Do not move or carry by cord, use cord as a handle, close a door on cord, or
pull cord around sharp corners. Keep cord away from heated surfaces.
• Do not run cord under carpeng.
• Do not cover cord with throw rugs, runners or similar coverings. Do not route
cord under furniture or appliances.
• Arrange cord away from trac areas so it will not be tripped over.
• Do not unplug by pulling cord. To unplug, grasp the plug, not the cord.
• Do not handle plug or appliance with wet hands.
• This model is for household use only. Plasc lm can be dangerous. To avoid
danger of suocaon, keep away from children. Do not plug in your air purier
unl you are familiar with all instrucons and operang procedures. To reduce
the risk of electrical shock, turn power switch o and disconnect polarized plug
from electrical outlet BEFORE performing maintenance or troubleshoong
checks.
• Do not put any object into openings. Do not use with any opening blocked;
keep openings free of dust, lint, hair and anything that may reduce airow.
• Keep hair, loose clothing and ngers away from openings. Turn OFF device
controls before unplugging the appliance. Do not use appliance in an enclosed
space lled with vapors given o by oil-based paint, paint thinner, moth-proof-
ing substances, ammable dust or other explosive or toxic vapors.
• Keep appliance on a level surface. Do not immerse the unit in waters or other
liquids, do not pour liquids into or around the unit or openings. Do not use the
appliance near water or in a damp or wet locaon.
• This appliance has a polarized plug (one blade is wider than the other). To
reduce the risk of electric shock, this plug is intended to t in a polarized outlet
only one way. If the plug does not t fully in the outlet, reverse the plug.
• If it sll does not t, contact a qualied electrician. Do not aempt to defeat
this safety feature.
• Do not use the appliance with any dimmer switch or solid state speed control
device.
• Only clean appliance with a clean, dry cloth. Do not use water or other liquid
cleaning products on the appliance; these items pose a re, electrical shock, or
injury risk.

READ AND SAVE
THESE INSTRUCTIONS

getting those most from your Sequoia
1.
give it room to breathe
The Sequoia pulls air in from both the front and the back,
so placing it away from any walls will help to maximize
airow. It’s designed to remove inanimate parculate
maer down to 0.1 microns in large, mul-purpose rooms
like oces, classrooms, conference rooms, and open oor
plan living rooms.
run it all the time
The Sequoia’s automac mode circulates the air quietly
and eciently and will increase speed if it detects any
inanimate parculate maer in the environment. No need
to ever turn it o, just set it on auto and enjoy cleaner air.
keep it well-oiled
Figuravely speaking, of course. The Sequoia requires no
maintenance other than a dry wipe down the exterior, a
wipe down of the outside of the lter, and regular lter
changes every six months. There is a handy light on the
top of the machine that will let you know when it is me
to clean the exterior of the lter. Be warned: the interior
of the lter cannot be washed or cleaned and must be
replaced when dirty. Depending on your environment,
expect to replace the lter every 4-6 months.

setting it up / changing the lter
2.
step 1:
Unlock the housing
using the switch on the
base of the Sequoia.
step 2:
Li the housing up
and over the lter and
remove the plasc bag
from the lter.

step 3:
Replace the lter with
the open side up and
reinstall the housing by
liing it up and over the
lter. Lock the housing
using the switch on the
base.
step 4:
Press the power buon,
the auto buon to
engage automac mode,
and enjoy clean, fresh
air.
+
=

operation
3.
fan speed control
press to cycle through fan speeds 1-4
sleep mode
press to turn on or turn o sleep mode.
The sleep icon will ash for 5 seconds
before the unit enters into sleep mode.
Under sleep mode, all lights (except sleep
indicator) will turn o and fan will turn at
sleep speed. Press sleep buon again or
any buon to quit sleep mode
dimmer
press to adjust the brightness of the unit
child lock
long press this buon for 5 seconds to
enter or exit the child lock mode
lter reset
press to check the remaining life (%) of
the lter. Aer 6 months of operaon
this indicator will turn on, alerng you
to check the lter to see if it needs
replacement. Press and hold this buon
for 5 seconds to reset the indicator light

timer
press to to set an operang me of
between 1 and 12 hours
air quality indicator
displays current air quality in the room,
giving a number from 0-999. PM2.5 is
the reading from the parculate sensor,
and TVOC is the reading from the Volale
Organic Compound sensor
fan speed indicator
displays the current fan speed
air quality indicator ring
illuminates green, yellow, or red to
demonstrate current air quality

automatic mode
Automac mode is the principal operang mode of the
Sequoia, and is the seng you should use to get the most out
of your machine.
When in automac mode, the Sequoia will adjust the fan
speed to provide the most ecient air cleaning possible.
The Sequoia will gently recirculate the room’s air at whatever
minimum fan speed you select. When the laser parculate
sensor or volale organic compound sensor detects the
presence of inanimate parculate maer or odors, the fan
speed will increase to maximum to clean the air as quickly as
possible. Aer the parculate maer is no longer detected,
the machine will return to its previous speed and connue to
circulate air.
To engage automac mode, simply press the buon. To
disengage, press it again.

excellent
< 50μg/m350-99μg/m3> 100μg/m3
poor very poor
air quality indicator
The Sequoia ulizes its two sensors to display the current air
quality in the room via the numerical display and colored ring
on the front. The laser parculate sensor detects inanimate
parcles in the 1 μm, 2.5 μm, and 10 μm range. The numeri-
cal display alternates between the 2.5 μm parculate reading
(PM2.5) and the volale organic compound (VOC) sensor
reading.
When either sensor detects inanimate parculate maer or
odors, the ring will change color to indicate the quality of the
air. If the Sequoia is in automac mode, the fan speed will
increase to clean the air as quickly as possible. As soon as the
inanimate parcles are reduced, the speed with decrease back