Global Industrial 412651 User manual

1MODEL # 412651, 412652, 412653, 412654, 412655
User's manual Manual del usuario Manuel de l'utilisateur
Customer Service
US: 1-800-645-2986
Servicio de atención al Cliente
US: 1-800-645-2986
Service à la clientèle
Canada: 888-645-2986
SPECIFICATIONS
Product Standard GB/T11883-2017
Accuracy Grade III
Zero Range 100% Full Scale
Time to Stable
Reading
<10 Seconds
Display Specicaons 5-digit Super High Brightness 25
mm red LED display
Or 5-digit 20 mm FSTN LCD display
with back lighng
Hanging Fixture 360-degree swirl safe hook &
shackle
Operang
Temperature
-10°C ~ +40°C
Operang Humidity 30% ~ 90% RH
Auto Power O 30 minutes aer the scale inacve
or at extreme low power supply
Internal circuit with
charging protecon
To enhance the energy of baery
and prolong its performing life
Scale casing Cast aluminum casing, corrosion
safe, an-stac and light weight
Keypad Light touch keypad
The keypad includes On/O, Units, Zero, and Hold.
(Note: The above keys can be used in sub-menu to set up lb-kg
conversion, Hold, Beeper On/O, Zeroing and backlighng,
etc.)
Max. Capacity Division Max. Capacity Division
6000 lb 1 lb 3000 kg 0.5 kg
10000 lb 5 lb 5000 kg 2 kg
20000 lb 10 lb 10000 kg 5 kg
KEYPAD FUNCTIONS
1. [HOLD] : Press this key to keep the current weight and there
is a LED indicaon lamp on the boom of the display window.
Press this key again when the displaying weight ickers to
cancel the HOLD funcon.
2. [UNITS] : Press this key to change units between lb and kg.
3. [ZERO] : Press this key to set the current weight to zero.
SCALE OPERATIONS
1. Turn on the Scale
Press the power switch located under the displaying window
of scale. The scale’s maximum weighing capacity is rst shown,
and then the scale goes through a self-check sequence.
5 seconds later, the scale will stabilize and be ready for
operaon. (Note: it is recommended to allow scale 3~5 minutes
of warm-up me before starng weighing operaon).
2. Zeroing
In default, the scale shows “0kg” or “0.0kg” aer it is turned
on. In case the display is showing numerical value other than
“0”, press [ZERO] on the keypad or the remote to set the
display to “0”.
3. Weight Measurement
a) Once the load is suspended completely, the display shows
the weight value of the load. When the “Stable” indicator is lit,
weight value can be recorded.
b) In case there is tare such as cable, load the tare and press
[ZERO] to zero the display to “0”kg. The weight value aer
this will be the net weight. This will not change unl the tare
change or the scale being turned o.
4. Turn O the Scale
Aer weighing operaon, press the power switch to shut o
the power completely to prevent the leakage of the baery.
Models: 412651, 412652, 412653, 412654, 412655
Heavy Duty LED Digital Crane Scale W/Remote

2
Heavy Duty LED Digital Crane Scale W/Remote
BATTERY CHARGING INSTRUCTIONS
a. Then indicator will be on if there is low power. The baery needs to be charged now. The scale, however, can
connue to operate for about 5 hours without charging.
b. Aer the indicator is ON for several hours without charging or there is no more power in the baery, the scale
will be powered o automacally.
c. Aer baery charging, if there is no display, it indicates that either there is diculty in baery charging or a damaged
baery. To prolong the baery life, we suggest you charge the baery aer using 48hours or no less than once per week.
To avoid any damage to the baery, please charge it correctly. Addionally, we suggest you switch o the scale to shorten
the charging me. The charging lamp on the displaying window and adaptor will turn red during charging. When the
charging lamp on the adaptor becomes green, it means the baery is fully charged.
PRECAUTION
1. Please charge the scale with standard charger.
2. The load placed on the scale hook must not exceed the maximum weighing capacity of the scale.
3. Perform roune inspecon and maintenance to ensure operaon safety for these basic items:
a) Check for loose bolts.
b) Check hook and shackle for deformaon, wearing and tearing.
c) Check other scale component for signs of metal fague.
d) Check for missing hook latch.
e) Avoid hing, bumping the display window.
f) Do not use the scale in the rain or heavily polluted environment.
g) If the scale is not going to be used for some me, please clean it, remove the baery and store it in
dry condions.
CALIBRATION METHOD
Please do not aempt to calibrate the scale without standard weight
Step Operaon Display Remarks
1Press & Hold [ZERO]
Key to power on
00000 Input the password “*****”
2Press [ZERO] to
conrm
SPAn Enter into seng state, and make sure the
scale is with non-load.
3Press [HOLD] Key SEt
00000
It will display “00000” aer 5 seconds.
4Press [HOLD] Key to
add Press [UNITS] Key
to move the digit le
3000 Load the scale. The closer to full capacity the
beer. For example, 3000kg
5Press [ZERO] HOLd The scale will record the new calibraon data.
User Manual

3
Heavy Duty LED Digital Crane Scale W/Remote
SETUP FUNCTIONS IN SUB-MENU
Display Remarks
Sets buzzer Press [UNITS] during self-check
sequence from “99999” to
“00000”
bEE 1 0: Disable
1: Enable
Press [HOLD] or [UNITS] to change.
Press [ZERO]
Hod 1 0: Disable
1: Enable
Press [HOLD] or [UNITS] to change.
Press [ZERO] Stb 0
0: zeroing allowed when unstable
1: zeroing not allowed when unstable
Press [HOLD] or [UNITS] to change.
Sets units Press [ZERO]
CHt 0
0: lb
1: kg
Press [HOLD] or [UNITS] to change.
Press [ZERO]
OFF 1
Press [ZERO]
Aut 1
0: Manual
1: to Auto
press [HOLD] or [UNITS] to change.
Save results Press [ZERO]
YES 0
------------- Press [ZERO]
SCHEMATICS
Dimensions
开/关
源
电
Model L F C G D
683412651
unit : mm
412652
412653
412654
412655
80 60 176 52
787 90 70 191 52
787 90 70 191 52
590 76 50 167 50
590 76 50 167 50
User Manual

4
Heavy Duty LED Digital Crane Scale W/Remote
ERROR INFORMATION
Fault analysis by checking the internal code
load on the scale, the internal code should be between 6000 and 8000. If the internal code is not in the range from 6000 to
8000, please send the scale back to your supplier for repair.
User Manual
REMOTE CONTROL
Fault analysis by checking the internal code
【Zero】: To zero the displaying weight.
【Hold】: Keep the current displaying weight and the indicang lamp will be lit.
【+/BL】: Turn on the backlighng. . (Only applies when the scale has a LCD display.)
【SW】: Change the division value between measured division and hi-resoluon division.
Baery : 9V/6F 22 layer-built baery.
Note : Please extend the antenna before using the remote control.
This manual suits for next models
4
Other Global Industrial Scale manuals

Global Industrial
Global Industrial 318503 User manual

Global Industrial
Global Industrial 318504 User manual

Global Industrial
Global Industrial 412552 User manual

Global Industrial
Global Industrial 412584 User manual

Global Industrial
Global Industrial 412672 User manual

Global Industrial
Global Industrial 412659 User manual