Push button sensor 3 basic 1-gang
Push button sensor 3 basic 2-gang (1+1)
Push button sensor 3 basic 3-gang
Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
628x1220

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
Table of Contents
Product definition1 3.................................................................................................................
Product catalogue1.1 3...........................................................................................................
Function1.2 3..........................................................................................................................
Accessories1.3 4.....................................................................................................................
Installation, electrical connection and operation2 5..............................................................
Safety instructions2.1 5...........................................................................................................
Device components2.2 6........................................................................................................
Fitting and electrical connection2.3 7......................................................................................
Commissioning2.4 10.............................................................................................................
Operation2.5 11......................................................................................................................
Technical data3 12....................................................................................................................
Software description4 13..........................................................................................................
Software specification4.1 13...................................................................................................
Software "Push button sensor 3 basic"4.2 14.........................................................................
Scope of functions4.2.1 14.................................................................................................
Notes on software4.2.2 15..................................................................................................
Object table4.2.3 16...........................................................................................................
Parameters4.2.4 18............................................................................................................
Appendix5 22.............................................................................................................................
Index5.1 22.............................................................................................................................
KNX
Product documentation
Page 2 of 23

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
1 Product definition
1.1 Product catalogue
Product name: Push button sensor 3 basic 1-gang / Push button sensor 3 basic 2-gang (1+1) /
Push button sensor 3 basic 3-gang
Use: Sensor
Design: UP (concealed)
Order No. 5111 00 / 5112 00 / 5113 00
1.2 Function
When its buttons are pushed, the push button sensor basic sends telegrams to the KNX / EIB,
depending on the parameter settings in the loaded application program. These can be, for
instance, telegrams for switching or pushbutton control, for dimming or for controlling blinds. It is
also possible to program value transmitter functions such as dimming value transmitters or light
scene extensions.
The push button sensor basic consists of up to 3 control surfaces, depending on the device
variant. The control concept of a control surface can be configured in ETS for the functions
"Switching", "Dimming", "Blind", "Value transmitter" and "Scene extension". The control concept
is defined as "Rocker". With the rocker function, one control surface is divided into two actuation
pressure points with the same basic function.
The push button sensor basic is equipped with two red status LEDs per control surface (left &
right), which are always controlled in the same way. The status LEDs can either be switched on
or off permanently, or can function as a status indicator for a button or rocker.
The labelling field of the pushbutton can be illuminated. If no or a wrong application has been
loaded into the pushbutton sensor with the ETS, the backlighting flashes with a frequency of
approx. 0.75 Hz to indicate an error, and in this case the pushbutton sensor does not work.
The device's programming mode is indicated by a separate programming LED, which is located
on the front below the decorative covers directly adjacent to the programming button. In this
manner the device can be commissioned easily with the ETS even in the installed state. Project
planning and commissioning of the device is performed using the ETS 3.0d with Patch A or
newer versions.
The push button sensor basic must be plugged onto the flush-mounted bus coupling unit 3
(see Accessories). Only the combination of this bus coupling unit and the pushbutton sensor
cover results in a functional unit.
Plugging the pushbutton sensor onto a flush-mounted bus coupling unit 1 or 2 (older
generation) is not possible.
Page 3 of 23
Product definition

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
1.3 Accessories
Bus coupler 3 Order No. 2008 00
Inscription sheet Order No. 1090 00
Second support ring Order No. 1127 00
Rocker set 1-gang Order No. 2131 ..
Rocker set 2-gang Order No. 2132 ..
Rocker set 3-gang Order No. 2133 ..
Page 4 of 23
Product definition

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
2 Installation, electrical connection and operation
2.1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons. The
applicable accident prevention regulations must be observed.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Make sure during the installation that there is always sufficient insulation between the
mains voltage and the bus. A minimum distance of at least 4 mm must be maintained
between bus conductors and mains voltage cores.
The device may not be opened or operated outside the technical specifications.
Page 5 of 23
Installation, electrical connection and operation

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
2.2 Device components
Figure 1: Device components of push-button sensor 3 basic
(1) Control surfaces
(1 x rocker switch with actuation point on left and right / colours depend on design)
(2) Status-LED red
(2 x per control surface / always controlled identically)
(3) Labelling field with backlighting (39 x 54 mm)
(4) Central web (colours depend on design)
Dimensions (1-gang & 3-gang):
Width (W): 55 mm / Height (H): 55 mm / Depth (D): 10 mm
Dimensions (2-gang):
Width (W): 55 mm / Height (H): 126 mm / Depth (D): 10 mm
iSpecifications without flush-mounted bus coupling unit, without fastening brackets and
without design frame.
iNeutral inscription panels are included with the devices as part of the scope of supply. If
necessary, individual labels can be created using optionally available labelling sheets (see
Accessories) and labelling software, or on the Internet at marking.gira.com.
Page 6 of 23
Installation, electrical connection and operation

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
2.3 Fitting and electrical connection
Fitting and connecting a device for device variants 1gang and 3gang
Figure 2: Device fitting using the example of a push button sensor 3 basic 1-gang
(5) Flush-mounted bus coupling unit 3 with supporting frame
(6) Design frame
(7) Pushbutton sensor cover
(8) Fit bolt for anti-theft protection (included with the pushbutton sensor cover)
(10) Inscription panel
(11) Rocker cover
The pushbutton sensor cover must be plugged onto a flush-mounted bus coupling unit 3. Anti-
dismantling protection is provided by screwing to the supporting frame of the bus coupling unit.
oConnect the bus coupling unit (5) with the KNX/EIB bus cable and fasten in place in an
appliance box.
oRemove the rocker covers (11) and inscription panels (10) from the pushbutton sensor
cover (7).
oPosition the design frame (6) in front of the bus coupling unit and carefully plug the
pushbutton sensor cover into the bus coupling unit.
oScrew the pushbutton sensor cover to the supporting frame of the bus coupling unit. Use
the screw (8) provided.
oIf necessary, label the inscription signs. Optionally the separately available labelling sheets
(see Accessories) can be used.
oFinally, mount the rocker covers together with the labelling panel by snapping them on.
Page 7 of 23
Installation, electrical connection and operation

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
iBefore final fitting of the rocker covers, the physical address has to be loaded into the
device (see page 10).
Fitting and connecting the device for device variant 2gang
Figure 3: Device fitting of the push button sensor 3 basic 2gang (with frame, without central
web)
(5) Flush-mounted bus coupling unit 3 with supporting frame
(6) Design frame
(7) Pushbutton sensor cover
(8) Fit bolt for anti-theft protection (included with the pushbutton sensor cover)
(9) Screw and anchor set for mechanical fastening and for anti-theft protection
(included with the pushbutton sensor cover)
(10) Inscription panel
(11) Rocker cover
Page 8 of 23
Installation, electrical connection and operation

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
The pushbutton sensor cover must be plugged onto a flush-mounted bus coupling unit 3. Anti-
dismantling protection is provided by screwing to the supporting frame of the bus coupling unit.
In addition, the lower part of the pushbutton sensor cover is screwed to the wall, or in the case
of mounting on 2 appliance boxes, to a second supporting frame. Mounting requires a design
frame 2gang without central web.
oConnect the bus coupling unit (5) with the KNX/EIB bus cable and fasten in place in an
appliance box.
oRemove the rocker covers (11) and inscription panels (10) from the pushbutton sensor
cover (7).
For mounting on only one appliance box, the lower part of the pushbutton sensor cover is
screwed to the wall with the aid of the supplied screw and anchor set (9). To do this, proceed as
follows:
oPosition the design frame 2gang without central web (6) in front of the bus coupling unit
and carefully plug the pushbutton sensor cover into the bus coupling unit.
oMark the drill hole positions on the wall. Do this by using the pushbutton sensor cover as a
template.
oPull the pushbutton sensor off of the flush-mounted bus coupling unit again. Drill holes
(Ø 5mm) and insert the anchors.
iThe use of the anchors depends on the properties of the surface.
oPosition the design frame 2gang without central web in front of the bus coupling unit and
carefully plug the pushbutton sensor cover into the bus coupling unit again.
oScrew the pushbutton sensor cover to the supporting frame of the bus coupling unit. Use
the screw (8) provided.
oIn addition, fasten the lower part of the pushbutton sensor cover in the predrilled holes with
the aid of the wall screws (9).
oIf necessary, label the inscription signs. Optionally the separately available labelling sheets
(see Accessories) can be used.
oFinally, mount the rocker covers together with the labelling panel by snapping them on.
For mounting on two appliance boxes, the lower part of the pushbutton sensor cover is screwed
to a second supporting frame (see Accessories). To do this, proceed as follows:
oMount the second supporting frame on the lower appliance box.
oPosition the design frame 2gang without central web (6) in front of the bus coupling unit
and the second supporting frame and carefully plug the pushbutton sensor cover into the
bus coupling unit.
oScrew the pushbutton sensor cover to the supporting frame of the bus coupling unit. Use
the screw (8) provided.
oScrew the lower part of the pushbutton sensor cover to the second supporting frame. Do
this using the screws included in the scope of supply of the supporting frame.
oIf necessary, label the inscription signs. Optionally the separately available labelling sheets
(see Accessories) can be used.
oFinally, mount the rocker covers together with the labelling panel by snapping them on.
iBefore final fitting of the rocker covers, the physical address has to be loaded into the
device (see page 10).
Page 9 of 23
Installation, electrical connection and operation

Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
2.4 Commissioning
Loading the physical address and application software
The commissioning of the device is basically confined to programming of the physical address
and the application data with the ETS.
Project planning and commissioning of the device using the ETS 3.0d with Patch A or newer
versions.
The device is connected and ready for operation.
An appropriate device must be created and configured in the ETS project.
Figure 4: Arrangement of the programming button and LED on the front of the device
The programming button is located on the front of the device behind a labelling panel (Figure 4).
Before final fitting of the rocker covers, the physical address has to be loaded into the device.
oDetach the control surface over the programming button/LED, if the rocker covers are
already fitted.
oActivating Programming mode: press the programming button (12).
The programming LED (13) lights up red.
oProgram the physical address with the help of the ETS.
The programming LED goes out.
oLoad the application data into the device using the ETS.
oMount control surface(s).
iIf the device was programmed with incorrect application data, then backlighting of the
labelling field flashes slowly. In this case, the device will not function after start-up.
Page 10 of 23
Installation, electrical connection and operation
This manual suits for next models
2
Table of contents
Other Gira Accessories manuals

Gira
Gira System 55 Pushbutton sensor 4 Standard User manual

Gira
Gira Observer 70 User manual

Gira
Gira 5461 02 User manual

Gira
Gira 5466 02 User manual

Gira
Gira 0873 00 User manual

Gira
Gira 5111 00 User manual

Gira
Gira 5471 00 User manual

Gira
Gira 5466 02 User manual

Gira
Gira 5068 00 User manual

Gira
Gira 0551 4 Series User manual

Gira
Gira CO2-Sensor User manual

Gira
Gira 1170 Series User manual

Gira
Gira 1117 00 User manual

Gira
Gira KNX/EIB User manual

Gira
Gira EDA 3902 F User manual

Gira
Gira 234902 User manual

Gira
Gira 5142 00 Operator's manual

Gira
Gira Touch sensor 2 User manual

Gira
Gira 5472 02 User manual

Gira
Gira 5472 02 User manual