GeoVision GV-R1352 User manual

GV-RK1352 and GV-R1352 Card Reader
The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards.
GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured with the
Wiegand and RS-485 outputs, the readers can be connected to any standard access control
panel. The readers are protected by a weather sealed and IP66 compliant housing for
outdoor use.
The content of this installation guide refers to the following readers:
GV-RK1352 firmware V1.2
GV-R1352 firmware V1.2
Packing List
GV-RK1352
1. GV-RK1352 Card Reader
2. Screw x 2
3. Screw Anchor x 2
4. Front Cover Plate x 2
Front View
GV-R1352
December 31, 2014
1
1. GV-R1352 Card Reader
2. Screw x 3
3. Screw Anchor x 2
4. Security Torx
Front View

1. Physical Descriptions
1.1 Electric Wire
GV-RK1352
Wire Color Function
Red DC 7.5 ~ 12 V
Black GND
Yellow Beeper
Orange Green LED
Light Red Red LED
Green Wiegand Data 0
White Wiegand Data 1
Blue RS-485 +
Light Blue RS-485 -
Rear View
GV-R1352
Wire Color Function
Red DC 7.5 ~ 12V
Black GND
Yellow Beeper
Orange Green LED
Light Red Red LED
Green Wiegand Data 0
White Wiegand Data 1
Blue RS-485 +
Light Blue RS-485 -
Gray N/A
Purple N/A
Brown N/A Rear View
December 31, 2014
2

1.2 Keypad (GV-RK1352 Only)
When accessing an entry using GV-RK1352, you can enter the door’s PIN code on the
keypad or present the card and then enter the card’s PIN code on the keypad to be granted
access. The access mode is defined on GV-ASManager.
1. 0~9 Number Keys: Press the number keys to enter the PIN code.
2. # Key: Press the # key to confirm the PIN code.
3. ﹡Key: Press the ﹡key to cancel the PIN code.
1.3 LED Indicator and Beeper
In standby mode, the LED is blue. When a card is read, the LED flashes green and the
beeper beeps once.
The reader comes with external control wires for Green LED, Red LED and Beeper. You can
connect these control wires to a GV-AS Controller to change the default settings of the LED
and Beeper. For details on how to configure the settings, refer to 5. Changing the Settings of
Beeper and LED later in this installation guide.
Note: You can only connect the LED and beeper wires to GV-AS210 / 2110 / 400 / 410 /
4110 / 810 / 8110.
December 31, 2014
3

2. Connecting the Reader to GV-AS Controller
You can connect the readers to GV-AS Controllers through Wiegand or RS-485 interface.
Note that the connection between the reader and GV-AS Controller varies with different
controller models. To see how many readers can be connected to a GV-AS Controller, refer
to The Number of Readers Supported by GV-AS Controllers table at the end of this
installation guide.
Note: GV-RK1352 / R1352 is compatible with GV-AS100 / 1010 / 110 / 120 / 210 / 2110 /
400 / 410 / 4110 / 810 / 8110. However, to enable the keypad function, you can only
connect GV-RK1352 to the controllers through the following interfaces.
GV-AS100 / 110 / 120: through Wiegand interface
GV-AS1010: through RS-485 interface
GV-AS210 / 2110 / 400 / 410 / 4110 / 810 / 8110: through Wiegand or RS-485 interface
2.1 Connecting through Wiegand Interface
The following diagrams use GV-RK1352 and GV-AS810 Controller as an example. Up to
eight readers can be connected to GV-AS810 Controller through the controller’s Wiegand
interface.
Wire Color Function
Black GND
White Wiegand Data 1
Green Wiegand Data 0
Red DC 7.5 ~ 12V
Wiegand A
Note: Connection through Wiegand interface is not supported for GV-AS1010.
December 31, 2014
4

2.2 Connecting through RS-485 Interface
The following diagrams use GV-RK1352 and GV-AS810 Controller as an example. Up to
eight readers can be connected together to the RS-485 interface on GV-AS810 Controller.
Connecting four or less readers to GV-AS810 Controller:
Wire Color Function
Black GND
Light Blue RS-485 -
Blue RS-485 +
Red DC 7.5 ~ 12V
December 31, 2014
5
Connecting five or more readers to GV-AS810 Controller:
For readers five to eight, connect the RS-485 cable to the RS-485 interface on GV-
AS810 Controller and then connect the 12V power output and GND of the reader to a
12V DC power output on the controller.

2.2.1 Defining Readers on GV-AS Controller Web Interface
Since multiple readers can connect to GV-AS Controller using one RS-485 interface, you
need to specify which door each reader controls. This section explains how to define readers
on the Web interface of GV-AS Controller. On the Web interface, you can also set the reader
to read the GID or UID on GV-AS ID Cards / Key Fobs. Note that the Web interface of
different GV-AS Controller models varies.
1. On the controller’s Web interface, click Extended Reader. This dialog box appears.
2. In the GV-Reader/CR420/GF1921/GF1922 section, select the RS485 checkbox in front of
the ID number and type the Serial Number on the rear panel of the reader. The ID
number will be assigned to the reader.
December 31, 2014
6
3. Select a door/gate for the reader from the Function drop-down list.

4. Next to Read Mode, select Read UID or Read GID to set the connected readers to read
UID (unique identifier) or GID (GeoVision ID) on GV-AS ID Cards / Key Fobs.
If you select Read GID, make sure there are two numbers on your GV-AS ID Cards / Key
Fobs as shown below. If there is only one number on your GV-AS ID Cards / Key Fobs,
GID is not supported and you must selec qu ification (UID).t Uni e Ident
5. Click Submit.
Note:
1. When you click Submit on the Extended Reader page of a GV-AS1010 / 210 / 2110 /
410 / 4110 / 810 / 8110, all readers connected through RS-485 interface will reboot.
2. GID ID format is only supported in GV-RK1352 / GV-R1352 V1.2 or later.
December 31, 2014
7

3. Installing the GV-R/RK/DFR Config AP
Th
master / slave status, and whether it reads UID or GID. When using the Config AP, the
reader needs to be connected to a PC through GV-COM, GV-Hub or GV-NET/IO Card V3.1.
e GV-R/RK/DFR Config AP allows you to set the reader’s beeper / LED, ID number,
You can inst fig AP from the Software DVD or GeoVision Website. To use a GV-
OM, GV-Hub or GV-NET/IO Card V3.1, you also need to install GeoVision USB Device
D
1. Insert the software CD and the Install Program window will pop up automatically.
2. Select Install GeoVision USB Device Driver.
3. In the GeoVision USB Driver Installer window that appears, select Install.
4. Go back to the Install Program window, and select Run GV-Reader Config Utility.
Downloading from GeoVision Website
1. Go to the Software Download and Upgrading page of GeoVision Website:
http://www.geovision.com.tw/english/5_8_AS.asp
all the Con
C
river.
Installing from Software CD
2. Find the Supplemental Utilities section under the Access Control tab, and click the
Download icon of GV-RK1352 & GV-R1352 & GV-DFR1352 Config Utility.
3. Under the Driver section, click the Download icon
December 31, 20148
of GV-USB Device Driver.

4. Overlaying Card Numbers on GV-System Live
View
You can overlay card numbers recognized at the reader onto a camera channel on GV-
System. To overlay card numbers on GV-System channel, the reader needs to be connected
to a GV-System through GV-COM, GV-Hub or GV-NET/IO Card V3.1.
RS-485
GV-HUB / GV-COM /
GV-NET/IO Card
RS-232
GV-System
(Light Blue) RS-485 -
(Blue) RS-485 +
USB
GV-RK1352
or GV-R1352
Note: GV-RK1352 / GV-R1352 is not compatible with GV-NET Card and GV-NET/IO Card
of versions earlier than V3.
4.1 Defining the ID Number and Setting the Reader to Slave
After the reader is connected to the computer of the GV-System, use the GV-R/RK/DFR
. Run GV-R/RK/DFR Config AP. Refer to 3. Installing the GV-R/RK/DFR Config AP above
Config AP to define the ID number of the reader and set the reader to Slave.
1
for how to install.
December 31, 2014
9

2. Select the COM port that is connected to the reader and click Open COM. The seria
number and firmware version of the reader will be automatically detected. The red s
next to
3. Under
l
quare
the COM port box should change to blue to indicate the COM port is correct.
Master / Slave, set the reader to Slave.
If you want to connect multiple readers to the GV-System, you need to set up a unique ID
number for each reader. For this you need to connect each reader to the computer one
reader at a time, and follow the instructions above to set up an ID number.
4. Select an ID number for the reader. The ID number ranges from 0 to 7.
5. Click Setup. The settings are sent to the reader.
Note:
1. If the COM port is incorrect, an “Error opening serial port”message will appear. To
verify the COM port that is connected to the reader, go to Windows Device Manager. In
the Ports (COM & LPT) field, you should see the entry for Prolific USB-to-Serial
Comm Port and the COM number currently in use.
2. If you are using an older version of the Config AP, you will have to manually type the
serial number of the reader. The serial number is on the rear panel of the reader.
December 31, 2014
10
Other manuals for GV-R1352
1
This manual suits for next models
1
Table of contents
Other GeoVision Card Reader manuals

GeoVision
GeoVision GV-PCR1251 User manual

GeoVision
GeoVision GV-CR420 User manual

GeoVision
GeoVision GV-R1352 V2B User manual

GeoVision
GeoVision GV-PCR310 User manual

GeoVision
GeoVision GV- RK1352 User manual

GeoVision
GeoVision GV- RK1352 User manual

GeoVision
GeoVision GV- DFR1352 User manual

GeoVision
GeoVision GV-Reader1251 User manual

GeoVision
GeoVision GV-Reader 1251 User manual

GeoVision
GeoVision GV-R1352 V2B User manual