GENI OBY-600 WASH User manual

CAUTION!
OBY-600 WASH
User manual

contents
Congratulations!
Thank you for purchasing OBY Series that elaborate manufactured
by Geni abundant experience of stage-lights. Hereafter you can get
high quality and low breakdown products on the market from Geni
Electronics Co., Ltd.; OBY Series concentrated unexpectedly
lighting effects for animating stages.
If any question or suggestion you have, please offer the precious
recommendation for improving our products and designs better;
and create perspective and expectancy about future lighting.
Inspection.
Description of the appearance
Features
Safety instructions
Lamp Installation
Rigging
Linking
DMX Channel Chart
Control Board
Replacing the Fuse
Product Specifications
Connection with the mains
1
2
3
3
4
5
6
6
7
11
12
13

Features
1
Great effect variety
!Delicate and streamline appearance to allow movement and
installation be easier
!Smooth 570 rotation angle about the x-axis and 270 rotation angle
about the Y-axis, electronic sensor to automatically reset
!CMY mixer to allow the color to be various and richer and make color
adjustment more accurate by adding offset color micro-adjusting
function
!One color disk with six dichroic color and open, which contains 3200
K CTC, be able to rotate in both directions smoothly to create heart-
touching rainbow effect, in order to make color adjustment more
convenient, a color macro function is added and in order to make
color adjustment more accurate, an offset color micro-adjusting
function is added
!10-30 degree ZOOM effect
!Frost lens with soft-edge frost
!1-12fps fast flash with random and 0-100% mechanical exposure
adjustment
Sophisticated appearance and structure design
Stylish, high impact resistant polymer shell, which is lighter than
anyone else of the same class in the market.
!
!Solid square base is convenient set on the TRUSS, or directly stand
on the ground or stage for uses.
!Systematic modular construction design has all inner function wheels
and PCBs modularized, which allows version update or customization
more convenient.
!Sophisticated optical system makes light output more bright and
sharp.
Simple and easy operation
!Standard USITT DMX512 protocol, 15 or 13 DMX Channel.
!High-torque stepper motors, smooth and precise micro-stepping
control.
!LED screen controls DMX coding and built-in functions' election, as
well as also display lamp's time usage.

Description of the appearance
Filter
2

Inspection
Carefully unpack the carton, and make sure if any damage or loss
caused by transportation.
Contact your Geni dealer to assure your right by telephone or
facsimile immediately if damage has occurred or if something is
missing.
Packing List:
A. OBY-600 Wash
B.Operating Manual
C.
D.Lamps (Optional)
Bracket
3
Safety instructions
This appliance must be earthed (grounded).
Disconnect power before removing covers or servicing.
Keep case closed while operating.
OBY-600 contains no user serviceable parts. Refer servicing to
qualified technicians only.
Lamp and components become hot during operation. Allow time to
cool before handling.
Keep flammable material at least one meter away from unit.
Do not operate in wet conditions or near liquids.
Keep air vents clear to avoid overheating.
Lamp produces hazardous UV light. Do not look directly at lamp
when lit.
Replace any blown or damaged fuses only with those of identical
values.

4
Lamp Installation
Warning
Remove the power cord before installing the lamp.
Keep projector-head upward (See Figure below.) and loosen four
screws on the cover with appropriate tool then open the top cover
and put it aside.
Loosen and grab the screws
on the shutter cover with
appropriate tool.
Wear the gloves and extract the lamp from
the package, loosen the screws on both sides of
the lamp, then slide the lamp paralleled into the
lamp socket. Adjust the round point of the
lamp upward (See Figure.) and fasten the
screws snugly.
Reverse the above-mentioned processes for
the complete installation.
Pull the reflector backward

5
a a
d
Oby-600 can be set on the flat stage floor directly or use clamp to mount on
any kinds of trusses for fitting the mobility of various venues.
Mount two attached brackets(a) on the bottom (See Figure ), and
collocate the appropriate clamps(b) to rig with trusses. Must use the
safety ropes that can hold the ten times as heavy as the fixture through
the eye bolts(c) on the bottom of the base and trusses; then join the
safety ropes with screw-on carabines(d).
Rigging:

6
Linking
Use 3-pin XLR data cables to link the controller to DMX lighting
equipment.
3-pin XLR connectors are follows:
Building a serial DMX-chain:
Connect the DMX output of the first fixture with the DMX input of the
next fixture. And execute all the setups following the above-
mentioned instruction.
Flip the DIP SWITCH #3 of last fixture to ON position for terminal
confirmation.
12
3
12
3
1:Ground
2:Signal(-)
3.Signal(+)
1:Ground
2:Signal(-)
3.Signal(+)
DMX-output
XLR mounting-socket:
DMX-input
XLR mounting-plug:
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
The earth has to be connected! In general, lighting effects should not
be connected to dimming-packs.

7
DMX Channel chart
CH 1
CH 2
CH 3
Dimmer
Shut
Color
wheel
CH 4
Cyan
CH 5
Magenta
CH 6
Yellow
0-255
0
0
1-7
18-35
8-63
36-51
64-71
52-71
72-127
72-89
128-135
90-107
136-191
108-127
192-199
128-187
200-253
188-195
254-255
196-255
0-255
0-255
0-255
Dimmer from dark to lightest.
Close
Open
Shutter from slow to fast.
Open
Fade out fast to slow.
Open
Fade in slow to fast.
Open
Open
Random shutter slow to fast
Reverse rotate from slow to fast.
White
Red
Blue
Green
Purple
3200K
Forward rotate from fast to slow.
Stop
From white to full cyan.
From white to full magenta.
From white to full yellow.
5000K

8
0-7
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-71
72-79
80-87
88-95
96-103
104-111
112-119
120-127
128-135
136-143
144-151
152-159
160-167
168-175
176-183
184-191
192-199
200-207
208-215
216-223
224-231
232-239
240-247
248-255
Macro off
Macro 1
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
Macro 13
Macro 14
Macro 15
Macro 16
Macro 17
Macro 18
Macro 19
Macro 20
Macro 21
Macro 22
Macro 23
Macro 24
Macro 25
Macro 26
Macro 27
Macro 28
Macro 29
Macro 30
Macro 31
CH 7
Color
macro
CH 8
CH 9
Beam
Zoom
0-63
64-127
128-143
144-255
Full beam.
o o
Zoom from 10 ~ 30
Frost filter.
Flat and wide beam effect at 0 .
Flat and wide beam effect can 90 adjustment.
0-255
Other manuals for OBY-600 WASH
1
Table of contents
Other GENI Light Fixture manuals
Popular Light Fixture manuals by other brands

Emos
Emos CLASSIC ZY1431T manual

Westinghouse
Westinghouse Outdoor Lighting Fixture owner's manual

Hedler
Hedler C 12 silent Operation manual

Blizzard Lighting
Blizzard Lighting Puck: CSI manual

Energetic Lighting
Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx
Lightmaxx Shaft 5R user manual

Cooper Lighting
Cooper Lighting Halo L3232E Specification sheet

Stageline
Stageline ODW-2410RGBW instruction manual

Light Sky
Light Sky Tornado Series user manual

Lightolier
Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier
Lightolier Lytespan 83ED17S specification

Lightolier
Lightolier Calculite CS8226 specification