FRIENDCOM FC-725 User manual

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 1/23
Friendcom has always been committed to technological innovation. Our aim is to
provide customers with timely and comprehensive service. For any assistance,
please contact our Shenzhen headquarters:
FRIENDCOM TECHNOLOGY CO., LTD.
7th Floor, 17 Building, Guangqian Industrial Park, Xili Town, Nanshan District, Shenzhen,
518055, China
Tel: +86-755-86026600 +86-755- 23230320
Fax: +86-755-86026300
For technical support, or to report documentation errors, please visit:
http://www.friendcom.com
NOTICE
Information in this document has been carefully reviewed and is considered to be accurate.
However, Friendcom assumes no liability resulting from any inaccuracies or omissions in
this document, or from use of the information obtained herein. Friendcom reserves the right
to make changes to any products described herein and reserves the right to revise this
document and to make changes from time to time in content hereof with no obligation to
notify any person of revisions or changes. Friendcom does not assume any liability arising
out of the application or use of any product described herein.
COPYRIGHTS
This manual and Friendcom products described herein may include or describe copyrighted
Friendcom material and are considered technical proprietary of Friendcom CO., LTD.
Accordingly, any copyrighted material of Friendcom and its licensors contained herein or in
Friendcom products described in this manual may not be copied, reproduced, distributed,
merged or modified in any manner without the express written permission of Friendcom.
TRADEMARKS
and Friendcom logo are registered Trademarks. All other product or
service names which are mentioned in this document are the property of their respective
owners.
Copyright © Friendcom Communications 2020. All rights reserved.

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 2/23
About This Document
Scope
Scope of this document is to present features and application of Friendcom IDUV915-LRW
Inductive Sensor Endpoint(Model name FC-725).
Audience
This document is intended for
system engineers (SEs),
application engineers,
and test engineers.
Related Documents
Friendcom_IDUV915-LRW_Inductive_Sensor_Endpoint_Terminal_Datasheet
Friendcom_IDUV915-LRW_Inductive_Sensor_Endpoint_Configuration_Guide
Conventions
Symbol
Indication
This warning symbol means danger. You are in a situation that could cause fatal device
damage or even bodily damage.
Means reader be careful. In this situation, you might perform an action that could result
in module or product damages.
Means note or tips for readers to use the module.

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 3/23
History
Issue
Date
Change
1.0
2021-01
Initial draft
1.1
2021-03
Modify the power consumption
1.2
2021-04
Modify the product name

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 4/23
CONTENTS
About This Document..........................................................................................................................2
1 Introduction........................................................................................................................................5
2 Product Concept...............................................................................................................................5
2.1 General Description...............................................................................................................5
2.2 Key Features.......................................................................................................................... 5
2.3 Curve freezing function introduction................................................................................... 6
2.4 Specifications..........................................................................................................................7
2.5 Safety Recommendations.................................................................................................... 8
3 Data Format and Setting Command............................................................................................. 9
3.1 Data Format of Reporting..................................................................................................... 9
3.2 Setting Command................................................................................................................ 14
4 Parameters Configuration............................................................................................................. 19
4.1 Parameters Configuration...................................................................................................19
4.1.1 Wireless Configuration Mode...................................................................................19
4.1.2 Entering Configuration Mode................................................................................... 19
5 Dimensions and Installation Instructions.................................................................................... 21
5.1 Dimensions........................................................................................................................... 21
5.2 Installation............................................................................................................................. 22
5.3 Transportantion and Storage............................................................................................. 22

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 5/23
1Introduction
This document describes the technical parameters and key functions which are connected
with customers’ applications, and it can help customers quickly understand the data format,
features, as well as other related information of IDUV915-LRW Inductive Sensor Endpoint.
2Product Concept
2.1 General Description
IDUV915-LRW Inductive Sensor Endpoint is a data acquisition and transmission terminal,
which is widely used in the intelligent construction of water meters, gas meters, and heat
meters. It can realize data collection, data storage management, abnormal warning and
wireless communication functions.
IDUV915-LRW based on a high performance LoRaWAN module, it supports standard
wireless LoRaWAN protocol.
IDUV915-LRW built-in high-performance non-magnetic metering module, can detect rotating
metal target in meters to measure the volume of flow. It is completely diamagnetic and has
strong anti-interference.
With pre-installed long-life battery and built-in antenna, the IDUV915-LRW has the
characteristics of simple deployment, high reliability, low power consumption and long
transmission distance.
2.2 Key Features
The following shows the key features of IDUV915-LRW.
Immunity of magnet interference.
Supports a range of event alarms including:battery life, reverse flow, Disassemble etc.
Waterproof: IP67.
Suitable to workin harsh environment.
Long range wireless data transmission.
Multi-band support, EU433, CN470, EU868, US915, AU915, IN865, etc.
Pre-installed long-life battery and built-in antenna.

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 6/23
Air wireless configuration.
Firmware upgrade by FOTA.
Average life 10 years*.
Lifetime depends from the device location and reporting interval.
2.3 Curve freezing function introduction
The IDUV915-LRW also supports more flexible data collection point configuration.
Compared to the traditional recording method, the curve freezing function can help users
record the usage of each time period of the day and report the data.
In order to meet this demand, the IDUV915-LRW program will average 96 time points in a
day, and the interval between time points It is 15 minutes, as shown in the table below.
Table 2-1 Collection Point Settings for Default Curves
Curve reporting function has two reporting frame format, one is the default curve reporting
frame, its acquisition point settings such as Table 2-1. ( 4 am to 11 pm every 1hour. 11 pm to
4 am every 15 minutes)
The other is the user-defined curve reporting frame. The user can set any desired data
collection plan by modifying the 12-byte mask. The mask corresponding to the above figure

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 7/23
is FFFF8888888888888888888F. The mask can be obtained through the separately
provided data collection schedule.
Due to the limitation of the data length of the reported frame, a maximum of 77 data
collection points are currently supported. If the collection point set by the user
exceeds 77, the mask and AT command will not be displayed.
2.4 Specifications
The following table describes the specifications of IDUV915-LRW
Table 2- 2 Specifications of IDUV915-LRW
Dimension
92mm (L) x 63mm(W) x 48.5 mm (H)
Weight
70g (The weight of packing material is not included)
Battery Life
Average life 10 years
Communication range
Up to 15km (In visibility conditions)
Radio Characteristics
Tx Power: Max. 20dBm
Rx Sensitivity: < -138dBm
Power Consumption
Average 8.5uA @ absence of water flow
Average 11.5uA @ presence of water flow
MAC Layer
LoRaWAN ®
IP Rating
IP67
Working Bands
EU433, CN470, EU868, US915, AU915, IN865, etc.
Operating Temperature
-40°C to +70°C (Industrial Grade)

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 8/23
Operating humidity
5%RH to 95%RH
Antenna Option
Build-in Antenna
Power Supply
Pre-installed long-life battery, 2.6V to 3.7V
Configuration
Over-the-air
Upgrade
FOTA
Environmental Compliance
RoHS, REACH
Certification
CE, FCC, LoRa Alliance*
“*” Means for features and certifications in planning
2.5 Safety Recommendations
Ensure that this product is used in compliant with the requirements of the country and the
environment, the following safety precautions must be observed during all phases of the
operation, such as usage, service or repair of wireless pulse acquisition products. If not so,
Friendcom assumes no liability for customers’ failure to comply with these precautions.
Full attention must be given to driving at all times in order to reduce the risk
of an accident. Using the terminal while driving causes distraction and can
lead to an accident. Please comply with laws and regulations restricting the
use of wireless devices while driving.
Wireless devices may cause interference on sensitive medical equipment,
so please be aware of the restrictions on the use of wireless devices when in
hospitals, clinics or other healthcare facilities.
The wireless terminal contains a transmitter and receiver. RF interference
can occur if it is used close to other electric equipment.

IDUV915-LRW Inductive Sensor Endpoint_User_Manual
Page 9/23
Do not use this product at any places with a risk of fire or potentially
explosive atmospheres such as gasoline stations, oil refineries, etc.
3Data Format and Setting Command
3.1 Data Format of Reporting
IDUV915-LRW actively reports data according to the set period. The format of reported data
frame can be set to four types: short format, long format, default curve and custom curve.
The information reported in the four formats is different, as follows:
Short data frame format:
Name
Byte
Note
Frame header
1
Fixed 0x56
Frame number
and status
1
Bit 4- Bit 7: Frame number
Bit 3: Downlink command successful reply mark,0 means no reply, 1
means the last command issued by the server was successfully
executed.
Bit 2: Open the lid detection mark, 0 means the shell is normal, 1 means
the shell is abnormal.This bit is cleared after the cover is re-closed.
Bit 1: Reverse flow identification, 0 means no reverse flow, 1 means
there is reverse flow.This bit is cleared after any report is successful.
Bit 0: Low voltage alarm flag, 0 means normal, 1 means abnormal
Reverse pulse
number
4
BCD code, unit L, current reverse cumulative count.
Data area
4
BCD code,Unit L, current cumulative number
Checksum
1
Accumulate sum, the cumulative sum of one byte of data from the frame
header to the check
Long data frame format:
Name
Byte
Note
Frame header
1
Fixed 0x55
Frame number
1
Data frame accumulator, value range 0 to 255, cyclic accumulation
This manual suits for next models
1
Table of contents