Franke T 200 User manual

T 200
Original Manual for Use and Maintenance
Read the operating instructions and the chapter
on safety information before operating the machine. Keep the
operating instructions near the machine.

II
11-03-2014 / LSC 044 / Rev. 00
WEEE
Disposal of the equipment by the users within the European Community ( WEEE) in compliance with the article 13 of the legislative decree is-
sued on 25 July 2005, nr151 ”Implementation of the directives 2002/95/CE,2002/96/CE e 2003/108/CE, concerning the decrease in the usage of
dangerous substances in the electrical and electronic equipment and the disposal of waste”.
The symbol of the crossed waste bin indicated on the equipment or on the packaging means that the product at the end of its lifetime must
be disposed of separately from all the other waste.
The separate collection of this equipment coming at the end of its lifetime is organized and run by the importer/distributor. The user who
should have to dispose of such equipment should get in touch with the importer/ distributor and follow the procedure they have adopted for
the separate disposal of the equipment coming at the end of its lifetime. The proper separate disposal of disused equipment so that it can
be recycled and treated according what is environmentally compatible contributes to avoid possible negative effects on the Environment and
on Health and allows the reutilization and/or the recycling of the materials the equipment is composed of.
The improper disposal by the user causes the enforcement of the administrative sanctions according to current regulations.

1
11-03-2014 / LSC 044 / Rev. 00
INDEX
1 GENERAL DESCRIPTION OF THE MACHINE ................................. 3
1.1 DESCRIPTION OF DELIVERY COFFEE TOUCHPAD................... 4
2. GENERAL ADVICE FOR THE INSTALLER ....................................... 5
2.1 GENERAL WARNINGS................................................................. 5
2.2 INSTALLATION REQUIREMENTS FOR THE USER...................... 7
2.3 WARNING/TECHNICAL DATA LABELS AND NAMEPLATES .........
APPLIED TO THE MACHINE........................................................ 9
3. REMOVING THE PACKAGING ....................................................... 10
3.1 STANDARD EQUIPMENT OF THE MACHINE............................ 10
3.2 OPTIONAL ACCESSORIES
(SUPPLIED ONLy ON REQUEST OF THE CUSTOMER)
................................... 11
4. COMMISSIONING THE MACHINE ................................................. 11
5. SWITCHING ON THE MACHINE .................................................... 12
5.1 COFFEE PREPARATION ............................................................ 13
5.2 EK MODEL ALARMS OPERATION............................................. 16
6 ROUTINE APPLIANCE MAINTENANCE
TO BE PERFORMED BY THE USER .............................................. 17
7 TECHNICAL DATA........................................................................... 19

2
11-03-2014 / LSC 044 / Rev. 00

3
11-03-2014 / LSC 044 / Rev. 00
1 GENERAL DESCRIPTION OF THE MACHINE
LEGEND
1. Top cup grid
2. Steam tap
3. Touchpad
4. Hot water tap
5. 2-cup filter holder
6. Steam wand
7. Drip tray grid
8. Water drip tray
9. Main on/off switch
10. Adjustable foot
11. Opening for gas burner inspection
12. Gauge
13. 1-cup filter holder
14. Hot water spout
15. Control knob for gas delivery (optional)
16. Piezoelectric lighter for gas (optional)
17. Electric cup warmer button (optional)
Fig. 1
43
1 2 2
3
6
15
16
13
14
10
17
9
8
7
6
5
1211

4
11-03-2014 / LSC 044 / Rev. 00
1.1 DESCRIPTION OF DELIVERY COFFEE TOUCHPAD
LEGEND
a. 1 short coffee preset delivery button
b. 1 long coffee preset delivery button
c. 2 short coffees preset delivery button
d. 2 long coffees preset delivery button
e. Continuous delivery key
Fig. 2
Touchpad model EK
ab
c e d

5
11-03-2014 / LSC 044 / Rev. 00
2. GENERAL ADVICE FOR THE INSTALLER
Read carefully the instructions and warnings contained in this manual and in the “INSTRUCTION MANUAL FOR THE INSTALLER”,
since they provide important indications concerning the installation of the appliance.
Attention!
The electric system, water supply system, drainage system and gas system (in case the appliance is pre-fitted for gas), MUST
already be put in place by the customer in order to allow the proper installation of the machine. The installation engineer cannot
change the existing system put in place by the customer. See chapter 2.2: “Installation requirements for the user”.
Attention!
The appliance must be installed where use and maintenance are restricted to trained staff.
Attention!
CAREFULLY READ THE FOLLOWING WARNINGS, WHICH OFFER IMPORTANT GUIDELINES FOR THE SAFE USE AND
MAINTENANCE OF THE APPLIANCE.
The appliance must only be used for its intended purpose and it must be installed in a suitable place for its use. Any other use is there-
fore considered as improper and unreasonable.
The manufacturer cannot be held liable for any damage caused by improper, incorrect or unreasonable use. Installation must be carried
out by qualified personnel according to current laws and to the manufacturer’s instructions. Incorrect installation may cause damage to
people, animals or property for which the manufacturer cannot be held liable.
2.1 GENERAL WARNINGS

6
11-03-2014 / LSC 044 / Rev. 00
Danger!
The electrical safety of the appliance is fully achieved only after it has been correctly connected to an earthing system as
required by the laws in force.
It is necessary to have the earthing connection checked by professionally qualified personnel. The manufacturer cannot be held liable
for any damage caused by the lack or inefficiency of the system’s earthing connection. The appliance has not been designed for outdoor
use. It must only be operated in a place where the ambient temperature is between
+5°C
and
+40°C
.
Attention!
The use of any electrical appliance also requires observance of the following important regulations.
• Donottouchtheappliancewithwetordamphandsorfeet.
• Donotusetheappliancebarefooted.
• Donotpullthepowersupplycordtounplugtheappliancefromthemainspower.
• Donotallowchildrenorunqualifiedpersonstousetheappliance.
• Accesstotheappliance’sserviceareamustberestrictedtothosepersonswiththerelevantpracticalexperienceandfamiliaritywith
the appliance itself, especially in terms of safety and hygiene.
• Thedeviceisnotintendtobeusedbypeople(childrenincluded)whosephysical,sensoryormentalcapabilityarereduced,unless
they could benefit, through the intermediation of a person in charge of their safety, of a guard or of instructions concerning the de-
vice’s use. Children must be kept under surveillance to be sure they wouldn’t play with the device.
• Beforecarryingoutanyroutinemaintenanceorcleaningoperation,disconnecttheappliancefromthemainspowerandshutoffthe
water supply tap.
• Intheeventofdamageand/ormalfunctionoftheappliance,switchitoffcompletelywithouttryingtomakeanydirectrepairs.Contact
the nearest Service Centre authorised by the manufacturer.
• Inordertoguaranteetheproperefficiencyandoperationoftheappliance,itisfundamentallyimportanttofollowthemanufacturer’s
instructions, and to follow a regular maintenance schedule.
• TheappliancehasIPX2 protection against water and therefore, it cannot be installed in areas where it may be subject to jets of water.

7
11-03-2014 / LSC 044 / Rev. 00
• Theappliancehasclass I protection against electric shocks.
• Thenoiseemittedbytheapplianceduringnormaloperationislessthan70 dB.
• NOTE:Appliancefittedtooperatewithgassystem.TheappliancehasbeenfittedbythemanufacturertooperatewithLPG under a
maximum supply pressure of 30 mbar. Adaptation to operate with any other type of gas must be carried out by personnel authorised
by the manufacturer.
Attention!
Failure to comply with the above regulations could jeopardise the correct operation and safety of the appliance as well as its
useful lifetime.
2.2 INSTALLATION REQUIREMENTS FOR THE USER
The appliance must be placed on a flat and stable surface and a
surface height for the appliance of no less than 1.2 metres from
the ground. Check this important requirement, since the manu-
facturer cannot be considered liable for any damage caused by
the instability of the appliance. While preparing the system, take
into account that a hole is needed in the bearing surface in order
to make all electric and water connections through the opening
below where a water softener will need to be fitted, if recom-
mended by the installation engineer.
A hole of
10 x 10 cm
is enough in the area (a) as indicated in
Pict. 3.
The machine needs a minimum clearance of:
- height 60 cm.
- width 40 cm.
- depth 40 cm.
Y
XX
A
2
13
4
Fig. 3
Legend:
1Single pole switch
with an opening of at
least 3 mm between
contacts.
2Water supply tap
3Drain siphon
4Gas supply tap (if fit-
ted)
Xmin. 20 cm.
Ymin. 40 cm.
Z* min. 10 cm.
*) Distance between the
back of the appliance
and the wall.

8
11-03-2014 / LSC 044 / Rev. 00
• Betweenthewatermainsandthewaterinletpipeoftheappliance,theremustbeataptostopthewaterflowifnecessary
(2 -
Pict
.3).
• Thewatermainspressuremustbewithintherangeof1 and 6 bar.
• Ifthisrequirementisnotmet,pleaseconsultthemanufacturer.
• Theapplianceissuppliedwithoutaplug.Itissupposedtobedirectlyconnectedtotheelectricmainsandtherefore,itisnecessary
to fit a single-pole switch with contact opening of 3 mm or more beforehand, according to the regulations in force
(1 -
Pict
.3).
• Thedrainpipeoftheappliancemustbedirectlyconnectedtoasuitableopendrainsiphon,previouslyinstalledbythecustomer(3
- Pict.3). Do not fit the drain pipe into basins or buckets placed under the counter as this will increase the possibility of forming dirt
deposits and as a result, the spread of bacteria
.
Attention!
The appliance is supplied without water in the boiler. This is to prevent serious damage if the appliance is exposed to low
temperatures. The appliance must only be supplied with cold drinking water.
Attention!
For appliances operating with gas, the gas supply tap must be fitted in an easily accessible place (4 - Pict. 3), so as to be able
to shut off the gas supply if necessary.
Regularly check the expiry date on the gas pipe connecting the system and the appliance and have it replaced by the Service
Centre before this date.
Table of contents
Other Franke Coffee Maker manuals

Franke
Franke SB1200 User manual

Franke
Franke A600 User manual

Franke
Franke Ecolino User manual

Franke
Franke SB1200 FM CM User manual

Franke
Franke Flair User manual

Franke
Franke Coffee machine Ecolino User manual

Franke
Franke SAPHIRA User manual

Franke
Franke Evolution User manual

Franke
Franke Frames CM FS 45 BK User manual

Franke
Franke Swiss Mambo Installation manual

Franke
Franke Mythos FMY 45 CM XS User manual

Franke
Franke A300 User manual

Franke
Franke Evolution User manual

Franke
Franke Evolution User manual

Franke
Franke Flair User manual

Franke
Franke SU03 User manual

Franke
Franke S700 User manual

Franke
Franke A1000 User manual

Franke
Franke A1000 User manual

Franke
Franke H User manual





















