FoxESS EPS Box-TP User manual



Table of Contents
1. Introduction ................................................................................................................................................................... 1
1.1 Wiring Diagram .................................................................................................................................................2
2. Preparation .................................................................................................................................................................... 4
2.1 Package Contents ............................................................................................................................................4
2.2 Tools ...................................................................................................................................................................4
3. Mounting ........................................................................................................................................................................ 5
4. Wiring Connection ........................................................................................................................................................ 6
4.1 Overview of EPS Box-TP ..............................................................................................................................10
5. Technical Parameters ............................................................................................................................................... 11


EPS Box-TP Series User Manual www.fox-ess.com P a g e | 1
1. Introduction
EPS Box-TP integrates two contactors which provides simple connection for users. It is compatible with equipment
with back-up function. Configured with EPS Box, customers just need to connect 3 wires between inverter and EPS
Box. It can simplify the operation and improve security.
Overview :
Objeto
Descripción
1
LOAD
2
EPS
3
ON-GRID

EPS Box-TP Series User Manual www.fox-ess.com P a g e | 2
1.1 Wiring Diagram
Note:the following is the wiring diagram of EPS BOX TP. It is necessary to connect the ON-GRID side of EPS BOX TP to
the power grid, connect the EPS port to the EPS port of the energy storage machine, and connect the LOAD port to the
load at home. The function of TP is to select the power of the load port from the GRID or the EPS port of the energy storage
machine.
Note: According to Australian safety requirements, the neutral cables of the on-grid side and backup side must be
connected together.Otherwise, the backup function will not work.
This diagram is an example for an application that neutral connects with the PE in a distribution box. For countries such as
Australia, New Zealand, South Africa, etc, please follow local wiring regulations.

EPS Box-TP Series User Manual www.fox-ess.com P a g e | 3
This diagram is an example for an application in which neutral is separated from the PE in the distribution box.
For countries such as China, Germany, the Czech Republic, Italy, etc, please follow local wiring regulations.Need internal
or external eps box, connect PE and the off-grid N line.

EPS Box -TP Series User Manual www.fox-ess.com P a g e | 4
2. Preparation
2.1 Package Contents
Before installation, make sure that nothing inside the package is damaged. The following items
should be inside the package.
2.2 Tools
Before you start, get the following tools ready.
Number
Items
Quantity
A
Expansion Screws
4
B
Expansion Tubes
4
C
Cushion Blocks
4
D
Self-Tapping Screws
4
E
AC Connectors
3
Diagonal Plier
Screwdriver
Rubber Hammer
①6 Driller
Marker Pen
A B C
D
E

EPS Box -TP Series User Manual www.fox-ess.com P a g e | 5
3. Mounting
Step 1: Install the four cushion blocks on EPS Box -TP with self-tapping screws.
Step 2: Use EPS Box-TP with cushion blocks as a template to mark the four holes' position on the wall with
marker pen.
Step 3: Drill holes with 力6 driller carefully, make sure the holes are deep enough for installing. Install the
expansion tubes through cushion blocks into the holes and tighten them.

EPS Box -TP Series User Manual www.fox-ess.com P a g e | 6
Step 4: Install the expansion screws with screwdriver to fix the EPS Box-TP.
4. Wiring Connection
Step1: Grid String Connection
EPS Box-TP is designed for three-phase grid. Per voltage range is 220/230/240V; frequency is
50/60Hz. Other technical requests should comply with the requirement of the local public grid.
Model(kw)
5.0
6.0
8.0
10.0
12.0
Cable (Load)
6.0mm2
6.0mm2
6.0mm2
6.0mm2
6.0mm2
Cable (ON-GRID)
4.0mm2
4.0mm2
4.0mm2
4.0mm2
4.0mm2
Cable (EPS)
4.0mm2
4.0mm2
4.0mm2
4.0mm2
4.0mm2
Micro-Breaker
32A
32A
32A
32A
32A
Step 2: Grid Wiring
•Check the grid voltage and compare with the permitted voltage range (refer to technical data).
•Disconnect the circuit-breaker from all the phases and secure against re-connection.
•Trim the wires:
-Trim all the wires to 52.5mm and the PE wire to 55mm.
-Use the crimping pliers to trim 12mm of insulation from all wire ends as below.
L1/L2/L3: Brown/Red/Green or Yellow Wire
N: Blue/Black Wire
PE: Yellow & Green Wire
Note: Please refer to local cable type and color for actual installation
Table of contents