Forza FDC-1002T User manual

User Manual
3-year
warranty*
Uninterruptible Power Supply System
FDC-1002T/FDC-2002T Online UPS

Table of contents
1. Introduction
1-1. Transportation
1-2. Preliminary steps
1-3. Initial setup
1-4. Important safety instructions
1-5. Maintenance, service and faults
2. Operation
2.1. Unpacking and inspection
2.2. Product overview
2.3. Installation procedure
2.4. UPS connections
2.5. ForzaTracker monitoring software
3. Advanced operation
3.1. Turning the UPS on and off
3.2. Touch panel and conguration menus
3.3. Audible alarm and LED indicators
3.4. Warning and fault codes
4. Troubleshooting
5. Storage and maintenance
6. Technical specifications

1
1. Introduction
Thank you for purchasing the Forza FDC-1002T and FDC-2002T Online UPS. To enjoy all the features and benets
of this unit, please read and follow all installation and operation instructions thoroughly before unpacking, installing or
operating this device. After you have read this manual, keep it in a safe place for future reference.
The information contained in this manual covers the 1000VA and 2000VA uninterruptible power systems, their main
functions, operating procedures, options available and troubleshooting guide. It also includes information on how to
ship, store, handle, and install the equipment.
1-1. Transportation
• Make sure to transport the UPS system only in the original package to protect it against shock and impact.
1-2. Preliminary steps
• Water condensation may occur if the UPS is unpacked in a very cold environment and then moved to a warmer
location.
• The UPS must be thoroughly dry before being installed. Failure to do so may increase the risk of electric shock.
• Do not install the UPS system near water or in moist environments.
• Do not install the UPS system where it would be exposed to direct sunlight or near a heater or heating vent.
• Do not block ventilation holes in the UPS housing.
1-3. Initial setup
• Do not connect appliances or equipment that may overload the UPS system (such as a laser printer) to the output
sockets.
• Place cables in such a way that no one can step on or trip over them.
• Do not connect domestic appliances, such as hair dryers, to the UPS output sockets.
• Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS
system.
• Use CE-marked cables for connections between mains, the UPS and equipment (shockproof outlet).
• Use CE-marked power cables to connect the loads to the UPS system.
• During the installation of this equipment, make sure that the sum of the leakage currents of the UPS and the connected
loads shall not exceed 3.5 mA.
1-4. Important safety instructions
• Do not disconnect the mains cable on the UPS system or the building wiring outlet (shockproof socket outlet) at any
time since this would cancel the protective earth of the UPS system and of all connected loads.
• Connect the UPS only to a grounded socket that meets electrical safety guidelines.
• Locate the UPS near a wall socket. Do not use an extension cord between the UPS and the socket.
• In the event of an emergency, press the power button and disconnect the power cord from the AC mains to properly
disable the UPS. Do not allow any kind of liquid or foreign object to enter this UPS unit.
• Do not place beverages or any other containers with liquid on or nearby the unit.
• The UPS can be operated by any individual with no previous experience.

2
1-5. Maintenance, service and faults
• The voltage used by this UPS may be hazardous. The unit contains no user serviceable parts; do not attempt to
disassemble the unit. Only qualied service technicians can perform maintenance on the unit. Failure to adhere to this
could cause personal injury or equipment malfunction and void the warranty.
• Caution - risk of electric shock. Even after the unit is disconnected from the mains, components inside the UPS
system are still connected to the battery packs which are potentially dangerous.
• Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current
is present and no hazardous voltage exists in the terminals of high-capacity capacitors, such as BUS-capacitors.
Servicing of batteries should be performed or supervised by experts who possess the knowledge to closely follow all
required precautions.
• Caution: potentially hazardous voltages from the battery can still be present even after disconnecting the UPS from
the AC mains. Therefore, the positive and negative terminals of the battery shall de disconnected prior to performing
any maintenance or repair inside the unit.
• A battery can present the risk of short-circuit current and electrical shock. The following precautions should be taken:
- remove wristwatches, rings and other metal objects
- use only tools with insulated grips and handles.
• When replacing the battery, make sure to use the same type and number of sealed lead-acid batteries specied.
• Do not dispose of batteries in a re. Batteries may explode if exposed to high temperatures.
• Never try to open a battery. The cell contains a toxic electrolyte which is harmful to the skin and eyes.
• Replace the fuse only with the same type and amperage in order to avoid re hazards.
• Do not dismantle the UPS system.
2. OPERATION
2-1. Unpacking and inspection
Remove the UPS from its package and make sure that all the following items are included:
• One UPS unit
• One user manual
• One monitoring software CD (ForzaTracker)
• One USB cable
• Warranty certicate
Carefully inspect the UPS to check for any damages that
may have occurred during shipping.
Should any evidence of damage be found or if some parts
are missing, do not turn the UPS on; you must immediately
notify the carrier or dealer where you purchased the
2-2. Product overview
Front panel view
1. Touch screen
2. Power button
12

3
Rear panel view
1. AC input
2. Input circuit breaker
3. USB communication port
4. RS-232 communication port
5. SNMP intelligent slot (optional)
6. Output receptacles
2.3. Installation procedure
Choose location
Install the UPS unit in any protected environment that provides adequate airow around the unit, and free from excessive
dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient
temperature or humidity is high. For best performance, keep the indoor temperature between 0° C and 40° C. Place the
UPS unit at least 20 cm away from monitors to avoid interference.
2-4. UPS connections
2-4.1 UPS input connection
Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords or adapter plugs.
2-4.2 UPS output connection
• For socket-type outputs, simply connect devices to the outlets.
FDC-1002T
FDC-2002T

4
USB port RS-232 port Intelligent slot
Communication port:
To allow for unattended UPS shutdown/start-up and status monitoring, connect one end of the communication cable to
the USB/RS-232 port, and the other end to the communication port of your PC. With the monitoring software installed,
you can schedule UPS shutdown/start-up and monitor its status through a PC.
The UPS is equipped with intelligent slot perfect for an optional SNMP card. When installing a SNMP card in the UPS,
it will provide advanced communication and network management tools.
Note: The USB and RS-232 ports cannot be used at the same time.
2-5. ForzaTracker monitoring software
ForzaTracker is a new generation of UPS monitoring software, which provides user-friendly interface to monitor and
control your UPS system. This unique software provides safe auto-shutdown for multi-computer systems during power
failures. With this software, users can monitor and control any UPS on the same LAN no matter how far they might be
from the UPS.
Installation procedure for Windows users:
1.Use the supplied CD or go to the website: http://www.forzaups.com.
2.After clicking the software icon, choose the required operation system.
3.Follow the on-screen instructions to install the software.
4. When you nished downloading all required les, enter the serial No (installation password): 5242-87f6-64re-di8d-
986u to install the software (include the hyphens).
5.In order to access as Administrator, input the password: 111296.
6.When your computer restarts, the management software will appear as a light blue round icon located in the system
tray, near the clock.
For MAC users, please refer to the ForzaTracker QIG inside the corresponding folder.
3. Advanced operation
3-1. Turning the UPS on and off
This UPS is equipped with a touch LCD panel. Designed for easy management, the 3in digital display features an
intuitive design, enhanced visuals, effective monitoring and system conguration, all done with a simple touch.
• There is only one physical button located on the front panel for POWER. It is used to perform the following
functions:
1. Press and hold the POWER button for 3 or more seconds to turn on UPS. Do the same to switch off the system.
2. If LCD panel is in sleep mode, simply press the POWER button less than 1 second for waking up the system.
3. If LCD screen crashes, press and hold the POWER button for at least 10 seconds to reboot the system.

5
3-2. Touch panel and configuration menus
As soon as power is supplied to the UPS, the LCD will be initialized automatically.
Once the process concludes, the LCD will change to display the main screen. By tapping on the icon on the
Home page, the ve sub-menus will come up: Control, values, setting, information, and data log.
Touch any of the sub-menu icons to enter into the sub-screen.
3-2.1. Main screen (Home)
• Upon powering on, the LCD will start the initialization process automatically which takes a few seconds to complete,
as shown below.
Menu tree hierarchy

6
• Once the starup process concludes, the main screen will be displayed.
Tap on the settings icon. That will bring up the ve icons representing ve sub-menus:
CONTROL, VALUES, SETTING, INFO, DATALOG.
3-2.2. Control screen
Touch the icon to enter the control sub-menu.
Touch the icon to return to the main interface, regardless of whether any of the submenu screens are active or
not.
Screen 1.0 «Control» and its sub-menus

7
UPS On/Off
It will display Turn on UPS? when the unit is off. It will display Turn off UPS? when the unit is on.
Tap on YES to power the UPS on or off. Then, the screen will return to the main interface.
Tap on Back to return to the main screen immediately or No to cancel this operation and restore the main menu inter-
face.
Battery test
When the UPS is not on test mode, Battery Test will appear on the screen.
• Tap on Yes to start; Battery testing will come up during the process. After a few seconds, the battery test result will
be shown on the screen.
• Tap on Back to return to the main screen immediately or No to cancel this operation and restore the main menu in-
terface.
• Stop battery test? will be displayed while the test is ongoing in the UPS.
TURN ON UPS
Battery Test
TURN OFF UPS
Cancel Battery Test

8
Audio mute
When audio is enabled, Mute all appears on the screen.
• Select Yes to mute the unit. If Mute all is enabled, the icon will appear on the top left corner of the main screen.
Touch Back to return to the CONTROL screen immediately or No to cancel this operation and restore the control
interface.
• Cancel mute all appears on the screen when the UPS audio has been silenced. Select Yes to enable audio or No to
keep the unit muted.
• Select Back if you want to return to the CONTROL screen.
3-2.3. Value screen
Touch the icon to enter value page. To navigate through the menu pages, simply tap the or arrows
on the screen. If you want to return to the main screen, touch the icon, and to go back to the previous menu,
select the return icon on the bottom center of the screen.
LINE VOLT: The real time value of the input voltage and frequency.
BYPASS VOLT: The real time value of the bypass voltage and frequency.
INVERTER VOLT: The real time value of the inverter voltage and frequency.
OUTPUT VOLT: The real-time value of the output voltage and frequency.
Mute All Cancel Mute all
Value screen - Page 1
This manual suits for next models
1
Table of contents
Other Forza UPS manuals

Forza
Forza FDC-1502R User manual

Forza
Forza Atlas 2-3KVA User manual

Forza
Forza FDC-106K User manual

Forza
Forza FDC-2012R-I User manual

Forza
Forza SL-1501UL User manual

Forza
Forza FDC-RT1000VA User manual

Forza
Forza FDC-106KMR-ISO User manual

Forza
Forza SL402UL-C User manual

Forza
Forza HT-750LCD User manual

Forza
Forza FDC-1002T-A User manual

Forza
Forza FDC-1002T-C User manual

Forza
Forza FDC-1001RUL User manual

Forza
Forza FIO-P11K12 User manual

Forza
Forza FX-1500LCD User manual

Forza
Forza SL402UL User manual

Forza
Forza HT-752LCD-C User manual

Forza
Forza Elipse Series User manual

Forza
Forza Elipse Series User manual

Forza
Forza SL-802UL-A User manual

Forza
Forza HT-752LCD-A User manual





















