Fluke MicroScanner Pro User manual

LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service. The warranty
period is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days. This war-
ranty extends only to the original buyer or end-user customer of a Fluke Networks authorized reseller, and does not apply to disposable
batteries, cable connector tabs, cable insulation-displacement connectors, or to any product which, in Fluke Networks’ opinion, has been
misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks war-
rants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly re-
corded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.
Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no
authority to extend a greater or different warranty on behalf of Fluke Networks. Warranty support is available only if product is purchased
through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price. Fluke Networks reserves the right to
invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another
country.
Fluke Networks’ warranty obligation is limited, at Fluke Networks’ option, to refund of the purchase price, free of charge repair, or replace-
ment of a defective product which is returned to a Fluke Networks authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then
send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke Net-
works assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB
Destination). If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal
condition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repair
costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation
prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL
NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING
FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or conse-
quential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held
invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforce-
ability of any other provision.
6/01
Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA

Table of Contents
Title Page
Introduction....................................................................................................................1
Features.......................................................................................................................... 2
MICROSCANNER PRO Kit Content ........................................................................................ 2
Registration..................................................................................................................... 3
Safety Information .......................................................................................................... 3
Contacting Fluke Networks ............................................................................................. 4
Battery............................................................................................................................ 5
The Keypad..................................................................................................................... 5
Operating Mode ............................................................................................................. 6
Calibration Mode............................................................................................................ 6
Setting the NVP percentage........................................................................................ 6
Changing the Display from Meters to Feet.................................................................. 7
MicroScanner Pro Tests ................................................................................................... 8

Length........................................................................................................................ 12
Network Link Indicator ........................................................................................... 14
Pair Length............................................................................................................. 17
Coaxial Cabling...................................................................................................... 18
Office Identifier........................................................................................................... 19
Toner .............................................................................................................................. 21
Technical Specifications ................................................................................................... 22

1
MicroScanner Pro™
Introduction
MICROSCANNER PRO™is an all-in-one network tester that
you can use to verify twisted pair and coaxial cables,
measure length and distance to faults via TDR, and
identify active networks and hubs.
M
ICRO
S
CANNER
P
RO
aue28f.eps
Figure 1. MicroScanner Pro

MicroScanner Pro
Users Manual
2
Features
•Tests unshielded twisted pair (UTP), shielded
twisted pair (SSTP) and coaxial cable
•Pinpoints opens, shorts, crossed and split pairs
•Measures cable length via TDR
•Checks and verifies wiremap
•Generates four different tracing tones to help
identify users
•Identifies active networking 10/100 hubs, switches,
and PCs.
MICROSCANNER PRO Kit Content
Your MICROSCANNER PRO kit contains the following:
•1 MICROSCANNER PRO network cable tester
•Wiremap adapter
•COAX adapter
•9 Volt alkaline battery
•Quick Reference Guide
•Product Manuals CD

MicroScanner Pro™
Registration
3
Registration
Registering your product with Fluke Networks gives
you access to valuable information on product updates,
troubleshooting tips, and other support services.
To register, go to the Fluke Networks website at
www.flukenetworks.com/registration and fill out the
online registration form. If you do not have Internet
access, print the registration form that is on the CD
included with the product. Fill out the form, then mail
or fax it to the appropriate address for your country.
Safety Information
WWarnings
Do not open the unit or attempt to repair
in case of malfunction. Please send it
back to your distributor for repair or
replacement.
Caution
MICROSCANNER PRO is designed to
withstand input voltage conditions that
arise from normal telephony applications
such as 48 VDC at less than 80 ma or 24
VAC used to power many keysets. Tests
cannot be performed when hazard
conditions exist on the inputs.

MicroScanner Pro
Users Manual
4
Contacting Fluke Networks
If you have technical questions, you may contact Fluke
Networks’Technical Support by phone, fax or e-mail.
www.flukenetworks.com
+1-425-446-4519
•Australia: 61 (2) 8850-3333 or 61 3 9329 0244
•Beijing: 86 (10) 6512-3435
•Brazil: 11 3044 1277
•Canada: 1-800-363-5853
•Europe: +44 1923 281 300
•Hong Kong: 852 2721-3228
•Japan: +81-3-3434-0181
•Korea: 82 2 539-6311
•Singapore: +65-6738-5655
•Taiwan: (886) 2-227-83199
•USA: 1-800-283-5853
Visit our website at www.flukenetworks.com for a
complete list of phone numbers.
Before calling Technical Support, please have your
Hardware and Software Version numbers available. To
find out the version numbers, do the following:
1. Turn off the MICROSCANNER PRO.
2. Simultaneously press the ,
MODE
, and
ON
OFF
keys.
The hardware and software versions of the
MICROSCANNER PRO are displayed.
Hardware Software
aue02f.eps

MicroScanner Pro™
Battery
5
Battery
MICROSCANNER PRO requires a 9 Volt Alkaline battery.
The Battery icon is displayed on the screen when
MICROSCANNER PRO detects a low battery condition.
Using MICROSCANNER PRO with a low battery may effect
the test accuracy.
If MICROSCANNER PRO is stored for more than one month,
the battery should be removed.
Note
MICROSCANNER PRO will not function properly
with a 9 Volt Carbon Battery.
The Keypad
ON
OFF
When turned on, MICROSCANNER PRO flashes the LCD
power-up test then resumes the test mode that was
last executed. MICROSCANNER PRO turns off automatically
when no cable is detected or when no key has been
pressed for 10 minutes.
To quickly change pairs or adjust values, press the
keys. These keys are active only if the indicators
are shown on the display.

MicroScanner Pro
Users Manual
6
Operating Mode
MODE
Press MODE to select the desired test. The available
modes are:
•WIREMAP
•OFFICE IDENTIFIER
•LENGTH
•TONER
Calibration Mode
MODE
+
ON
OFF
Turn the MICROSCANNER PRO OFF, then hold the MODE
key down while pressing the ON key to start Calibrate
mode.
Use MICROSCANNER PRO to calibrate cable lengths of
more than 50 feet (15 meters) and up to 1500 feet (457
meters).
Setting the NVP percentage
Once in Calibrate Mode, the default NVP (Nominal
Velocity of Propagation) will be displayed followed by
the overall cable length. The cable length is measured
with the currently stored NVP.
NVP is the measure of how fast a signal travels down a
cable compared to the speed of light. The result will be
represented as a percentage of the speed of light. For
an accurate length test, the NVP must be set correctly.
aue01f.eps
Table of contents
Other Fluke Test Equipment manuals

Fluke
Fluke 753 Use and care manual

Fluke
Fluke 5500A User manual

Fluke
Fluke NFK-LAUNCH Series User manual

Fluke
Fluke 9132 User manual

Fluke
Fluke AIRCHECK Instruction manual

Fluke
Fluke 725Ex User manual

Fluke
Fluke CableIQ CIQ-100 User manual

Fluke
Fluke 729 FC User manual

Fluke
Fluke ScopeMeter 190B Series User manual

Fluke
Fluke LinkIQ User manual

Fluke
Fluke 725 Operating and safety instructions

Fluke
Fluke AIRCHECK User manual

Fluke
Fluke 9040 Owner's manual

Fluke
Fluke 5730A User manual

Fluke
Fluke 1507 User manual

Fluke
Fluke 5520A Service User manual

Fluke
Fluke Versiv User manual

Fluke
Fluke 190 Series II User manual

Fluke
Fluke 9100 Series Instruction Manual

Fluke
Fluke 4180ETRS User manual






















