427-0073-11-28 Rev 100 Feb 2013
Step 4 Te r m i n a te c a b l e s :
Step 5 Connect a ground wire between the ground stud on the
back of the camera and the nearest earth-grounding point.
Step 6 Test camera: Power on the camera and test video.
Use a web browser to test IP communications
(default IP: 192.168.250.116; login: user/fliradmin)
Step 7 Tighten Cable seal gland nut to ensure a watertight seal.
Step 8 Replace cover: Alternately tighten the four captive
screws in the cover; torque to 1.8 N-m (16.0 in-lbs).
Connection Purpose
13-pinJumper Lensheateron/off
2 RCA Analog video test point
3BNC Analogvideo
4 3-pin Terminal AC/DC Power
5 Ethernet PoE power, communications, IP video stream
6 Accessory inputs Reserved for future use
Ta b l e 1 - 1 : Po w e r C o n n e c t o r
1Chassis
2VAC/DC-
3VAC/DC+
427-0073-11-28 v100 FC-Series S Quick Connect.fm Page 3 Saturday, March 9, 2013 5:07 PM