First Degree FLUID E720 User manual

1
Owners Manual
E720

2 Contents
1. Contents of E720 Box.
2. E720 assembly instructions.
3. Tank filling and water treatment.
4. Long term water treatment and basic
operation.
5. E720 Control arm.
6. Maintenance.
7. Troubleshooting guide
8. The E720 Ergometer.
9. Tank belt drive adjustment.
10. Parts list and Warranty.
As with any piece of fitness equipment, consult a physician before
beginning your E720 exercise program.
CAUTION
Use two hands and follow all safety in-
structions whenever raising or lower-
ing the E720 control arm.
Warning
Do not remove feet or hands while crank is in motion. The crank
will continue to rotate and could cause injury.
Training with E720

3
Box Contents
1x Upper seat frame
1x Main frame
1x Upper/Lower seat
frame
1x Lower seat frame
1x Right crank
pedal
1x L-pin
1x Fill funnel/hose
3x Leveler
Hex Keys 2x Batteries
3x Frame bolts 8x Seat bolts
7x Frame bolt washers
8x Seat bolt
washers
3x Main frame
Nylock nut 1x Multi-tool
M10 Plastic
Washer
Blue Dye
Owners Manual Touch Up
Paint
Chlorine Tab-
lets x 8

4
E720 Assembly Instructions
Upper seat
Lower seat
Step 1: Attach upper seat to
upper seat frame using 4x
M6x20mm bolts and 4x
16*6*l washers.
Step 2: Attach lower seat
to upper seat frame using
4x M6x20mm bolts and 4x
16*6*l washers.
Upper seat frame
M6x20mm bolt
M6*16*1 washer
M6*16*1 washer
M6x20mm bolt

5
Step 3: Attach lower seat to lower
mainframe using 2x M10x25mm
bolts, 2x M10 Nylock nuts and 4x
21*11*2 washers
M10 Nylock nut
21*11*2 washer
M10x25mm bolt
E720 Assembly Instructions

6
L-Pin
M10x25mm bolt
M10 Nylock nut
21*11*2 washer
Step 4: Lower upper seat frame onto lower mainframe and
secure using 1x M10x25mm bolt, 1x M10 Nylock nut, 3x
21*11*2 washers and L-pin.
Note: Tighten the M10x25mm bolt, washers and Nylock until
lightly snug only. Over-tightening will prevent the seat from
rotating. Use the L-pin to tighten the upper seat frame once
rotated into place.
E720 Assembly Instructions
M10 plastic washer

7
Step 5: Secure right pedal onto Crank arm. The
pedal threads have a blue coating which will feel very
tight when threaded onto the crank arm. This is a
type of thread locker, and once in contact with the
crank arm threads will activate in approximately
15minutes.
Caution! Extreme over-tightening could damage the
aluminum threads on the crank arm.
Note: Allow 15 minutes for the
thread-locker to activate before
first time use.
Check pedal tightness on a regular
basis and tighten as needed with a
15mm wrench.
E720 Assembly Instructions

8
Note: A large bucket is required for filling (Not included)
In areas where tap water quality is known to be
poor, FDF recommends the use of distilled water.
Tank filling and water treatment
Open the rear upper yellow tank plug and insert hose into
tank (rotating the impeller slightly may be necessary to al-
low the hose to pass), move the tank adjuster handle to
level 20 and begin filling. Do not fill the tank higher than
the level indicator on the front of the clear shell. A prop-
erly filled tank holds approximately 8liters of water.
Warning: Do not under any circumstances put
fingers into the tank. Use the end of the hose to
move the impeller should the need arise.
Water Treatment Procedures:
1. Add Chlorine tablet.
2. Wait a minimum of 72 hours.
Then add very small amount of blue
dye and check for desired color. Im-
portant! Do not add blue dye for at
least 72 hours following Chlorine
treatment. The blue dye adds visual
appeal as well as cutting down the
amount of light affecting the tank water,
thus extending the amount of time be-
tween water treatments.
Note: The blue
dye is extremely
concentrated and
will readily stain
carpet or clothing.
Caution: Use a drop cloth when filling or
adding blue dye
Blue Dye
Yellow
tank plug
Filling hose
and funnel

9
CAUTION
Caution: It is important that a drop
cloth be used under the fluid tank whenever
the tank plug is opened for water treatment.
The level of resistance is deter-
mined by the level indicator located
on the front of the tank. Level one
indicates lightest resistance, level
twenty represents heaviest resis-
tance. Allow three to four seconds
after adjusting resistance handle for
the correct resistance level to be
achieved.
Long term water treatment:
Do not use any water treatment other than the tablets
supplied with this machine. For replacement tablets, con-
tact your local First Degree Fitness distributor.
Water treatment schedules for the E720 will vary according
to the fluid tanks exposure to sunlight, but expect 8-12
months near a bright, sunlit window and 2 years or more for
a darker location. At the point of finding the water slightly
cloudy, add a Chlorine tablet. Remember to wait 72 hours
following the chlorine tablet before adding the blue dye as
the Chlorine tablet is extremely concentrated.
Important: Do not fill past the calibration mark as indi-
cated on the tank level sticker or water spillage may occur.
See tank filling/water treatment page for details.
Long term water treatment and basic operation
Resistance:
Warning:
Use two hands when either raising or lower-
ing the control arm as pictured.
Removing hands or feet before the crank
comes to a complete stop while training can
cause injury. The crank is direct drive so as
to allow both forward and reverse rotation
during training.

10
Chain tensioning bolts: Allows for tightening the chain or
adjustment from side to side. Make sure when tightening
only to adjust the same amount for both bolts, otherwise the
sprocket will be misaligned.
Note: Tightening the right bolt only will pull the right side of
the crank assembly toward you, tightening the left will pull the
left side toward you. Use this feature to realign the rear with
the front sprocket if needed or when changing to a new chain.
The E720 Pedal: This pat-
ented design allows for usage
in both the recumbent posi-
tion and for sitting/standing
upper body workouts.
L-pin: Loosen
when rotating
the control arm
and tighten
(snug only)
once the de-
sired position
has been
reached.
T-pin: The T-pin locks the con-
trol arm in any one of 72 different
positions throughout its 360 de-
gree range of motion. Pull up
the T-pin to allow the control arm
to rotate while supporting the
control arm with the other hand.
Crank arm bolts:
Loosen all 8 bolts
slightly before adjusting/
tightening chain.
The E720 Control Arm
Inspection plate: Open to check
chain tension.
Warning: Do not check
chain tension by hand!
Table of contents
Other First Degree Fitness Equipment manuals