Everflo EFHP-2000 User manual

EFHP-2000
Owner’s Manual
Instructions for Assembly, Testing, Operation, Servicing, and Storage
12V Plunger Pump: For use with non-potable liquids such as water-based
agricultural pesticides and other liquids**
WARNING
READ and UNDERSTAND the Owner’s Manual completely before using this pump.
Assemble, test, and use only in accordance with the Owner’s Manual instructions.
READ and FOLLOW chemical safety instructions. Pesticides are hazardous chemicals.
KNOW emergency procedures BEFORE handling chemicals. Pump leaks, bodily chemical
contact, poisoning, and spills require immediate response.
AVOID inhaling, ingesting, or coming into contact with any chemicals.
WEAR personal protective gear when operating, cleaning, and servicing the pump.
KEEP pump and spray materials away from children and pets. Pesticides are especially
toxic to them.
DO NOT TURN ON POWER to pump until ready to spray in order to avoid unintentional
spray release.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
Improper use of the pump or handling of chemicals could result in serious injury or
illness to the operator or nearby persons/animals, or could cause damage to the
environment.
** This pump is recommended for use in spraying non-flammable liquids such as pesticides, water
for plants/trees or dust control, or water-based non-flammable sealants or stains for outdoor wood
surfaces. This pump should not be used to transfer any product intended for human consumption.
WE RECOMMEND THAT THE PUMP NOT BE USED FOR OTHER PURPOSES ONCE IT HAS
BEEN USED FOR SPRAYING PESTICIDES. Any chemical will leave some residual in the pump,
even after the pump has been properly cleaned. These residual chemicals can have unexpected
effects on future uses. For example, spraying water or other liquids that are contaminated with
residual pesticide may result in unforeseen hazards to plant or animal life. This pump should not be
used by people with reduced physical, sensory or mental capabilities or lack of experience and
knowledge.
Any Questions, Comments, Problems, or Parts Orders
Call Everflo Product Support 1-800-864-1649
ITEM NUMBER: EFHP-2000
SERIAL NUMBER: __________

Hazard Signal Word Definitions
2

Table of Contents
3
Intended Use ........................................................................................................................................ 4
Summary of Important Safety Information...................................................................................... 5
During Assembly
During Operation
General Chemical Safety
Chemical Applicator Safety
Chemical Accident Procedures
Warning Label Location...................................................................................................................... 7
Unpacking ............................................................................................................................................. 8
Assembly................................................................................................................................................ 9
Installation
Step One: Mounting...................................................................................................................... 13
Step Two: Plumbing...................................................................................................................... 13
Step Three: Connect pump to vehicle battery............................................................................... 14
Step Four: Check and test completed assembly ........................................................................... 15
Operation
Important Safety Information - Operation.............................................................................. 16
General Chemical Safety
Chemical Applicator Safety
Chemical Accident Procedures
Preparing the Pump for Each Use............................................................................................. 20
Using the Pump
Step One: Assess wind conditions and clear work area........................................................ 21
Step Two: Operate the pump................................................................................................. 21
Step Three: Clean pump and decontaminate after use .......................................................... 23
Storage................................................................................................................................................. 25
Preparing for storage
Removing from storage
Troubleshooting.................................................................................................................................. 26
Specifications....................................................................................................................................... 28
Accessories........................................................................................................................................... 29
Parts Breakdown – Exploded View.................................................................................................. 30
Limited Warranty .............................................................................................................................. 31

Intended Use
4
The pump is intended for use in spraying agricultural pesticides and other non-flammable
liquids.
SPRAYING PESTICIDES:
Pesticides are hazardous chemicals that must be handled with caution as directed
throughout this manual and on the pesticide label. Pesticides are regulated by the United
States Environmental Protection Agency (EPA) and defined as:
Any substance or mixture of substances intended for preventing, destroying, repelling, or
mitigating any pest. Though often misunderstood to refer only to insecticides, the term
pesticide is a comprehensive term that applies to insecticides, herbicides, fungicides, and
various other substances used to control pests.
The pump is intended for use in spraying pesticides in liquid form only. The pump is
NOT intended for use in spraying pesticides in dry or aerosolized form, or for use with
fumigants.
SPRAYING OTHER LIQUIDS:
In addition to spraying pesticides, this pump may be used to spray other non-flammable
liquids. Example uses include: watering plants/trees or spraying water for dust control,
or applying water-based, non-flammable sealant or stain to outdoor wood surfaces.
However, WE RECOMMEND THAT THE PUMP NOT BE USED FOR OTHER
PURPOSES ONCE IT HAS ALREADY BEEN USED FOR SPRAYING
PESTICIDES. Any chemical will leave some residual in the pump, even after the pump
has been properly cleaned. These residual chemicals can have unexpected effects on
future uses. For example, spraying water or other liquids that are contaminated with
residual pesticide may result in unforeseen hazards to plant or animal life.
Contact Everflo Product Support at 1-800-864-1649 for any questions about
the appropriate use of the pump and/or optional accessories.

Summary of Important Information
5
WARNING
Read and understand this owner’s manual completely before using the pump. Read each
chemical label’s instructions before handling the chemical.
Improper use of the pump or handling of chemicals could result in serious injury or illness
for the operator or nearby persons/animals, or cause damage to the environment.
LISTED BELOW is a summary of safety information of particular importance. See individual
sections of this owner’s manual for more details.
------------------------------------ DURING ASSEMBLY-------------------------------
EXERCISE CAUTION when attaching remote switch to battery terminals. Follow the steps
listed in the Assembly section of this manual in exact sequence when connecting the pump to battery
terminals. Caution must be exercised to avoid contact with battery acid and to prevent sparking.
CHECK and TEST completed assembly as directed in this manual. Serious injury could result from
chemical leaks if pump is improperly assembled.
DO NOT MODIFY pump design.
------------------------------------DURING OPERATION------------------------------
General Chemical Safety
READ and FOLLOW each chemical label’s instructions and warnings.
AVOID inhaling, ingesting, or coming into contact with any chemicals.
KNOW applicable licensing and regulatory requirements for the chemical you plan to use.
KNOW emergency procedures before handling chemicals. Carefully review “Chemical Accident
Procedures” listed below and later in this manual. Also see First Aid instructions on the chemical
label.
WEAR protective clothing, eye protection, and chemical resistant gloves when operating the
pump. Wear additional protective gear, such as facemask or apron, as recommended on the chemical
label.
EXERCISE EXTRA CAUTION around children and pets. Pesticides are especially toxic to them.
Keep pump and spray materials away from them at all times.
DO NOT MIX OR POUR chemicals in an enclosed, unventilated area
DO NOT USE flammable or corrosive chemicals in the pump.
FLUSH the pump before switching chemicals in order to prevent dangerous chemical interactions.
STORE pesticides in a correctly labeled container and in a secure location.
MONITOR the health of operators frequently exposed to pesticides, as recommended by the
chemical label or local/federal regulations.
Chemical Application Safety
Before Spraying
INSPECT and PREPARE pump before each use as directed in this manual.
DO NOT TURN ON POWER to pump until ready to spray in order to avoid unintentional spray
release.
DO NOT SPRAY when wind speed exceeds 4 MPH in order to minimize spray drift.
CLEAR work area of people/ pets and POST warning notices to restrict access for the period
recommended on chemical label.
KEEP pump and spray materials away from children/pets. Pesticides can be especially toxic to
children and animals.
DO NOT ALLOW anyone younger than 16 to operate the pump since pesticides are especially
toxic to children.
During Spraying
DO NOT OVER-APPLY pesticide. Apply at rate recommended by chemical manufacturer. Excess
pesticide can be dangerous to humans/animals, damage desirable plants, and contaminate soil and
water sources.

Summary of Important Information
6
DO NOT EAT, DRINK, SMOKE, RUB YOUR EYES, or TOUCH YOUR BARE SKIN while
handling chemicals and spraying.
NEVER POINT A SPRAY GUN at people or animals.
EXERCISE EXTRA CAUTION when spraying near areas accessible to children and pets.
CLEAN up spills immediately per instructions on the chemical label.
TURN OFF power to pump, and RELIEVE system pressure before leaving pump unattended.
SEE Troubleshooting section of this manual before attempting any repairs. Wear personal
protective equipment and follow safety instructions.
After Spraying
CLEAN pump immediately after use according to the directions provided in this manual.
DECONTAMINATE yourself after you are done spraying and have cleaned the pump. Wash all
exposed areas of the body with soap and water, and remove and launder clothing.
DISPOSE OF or STORE remaining chemicals in secure storage with correctly marked
container.
Chemical accident procedures
Immediate response is necessary in the event of pump leaks, bodily chemical contact, poisoning, or
spills. See instructions below:
Pump leak If the pump develops a leak, immediately stop spraying. Turn off power to the
pump and follow directions below, as applicable.
Bodily
chemical
contact
Personal contamination can occur when chemicals splash, spill, or spray
directly onto a person.
1. Immediately follow First Aid instructions on chemical label.
General procedures can include:
a) Eyes – immediately flush with water.
b) Skin – wash all contaminated skin surfaces with soap and water.
c) Clothing – remove contaminated clothing. Dispose of heavily
contaminated clothing per chemical label instructions.
2. Seek medical advice if instructed on the label or the victim experiences
symptoms of harmful effects. Bring the chemical label for reference.
Poisoning by
ingestion or
inhalation
In case of poisoning from ingestion or inhalation:
If the victim has collapsed or is not breathing, call 911. Otherwise:
1. If you are the victim, immediately seek assistance from nearby personnel
because you may become incapacitated.
2. Immediately follow first aid instructions on chemical label.
3. Call a poison control center for further advice. In the U.S., call 1-800-222-
1222. Have the chemical label available for reference.
Chemical
spills Chemical spills must be quickly contained and properly cleaned up.
Refer to the chemical label for any specific clean-up instructions.
General procedures include:
1. Controlling the spill by stopping the source of the spill.
2. Containing the spill so that it does not spread and get into water sources.
3. Cleaning up the spill immediately.
4. Seeking additional advice from:
- Chemical manufacturer. See chemical label for contact information.
- State pesticide regulatory agency. In the U.S., call the National Pesticide
Info. Ctr. at 800-858-7378 for assistance in contacting your state’s agency.

Warning Label Location
7
Always make sure safety labels are in place and in good condition. If a safety label is missing or
not legible, order new labels or unsafe operation could result.
To order replacement safety labels, call Everflo Product Support at 1-800-864-1649.
Part# Description
796106 EFHP2000 Pump Label
793288 Pump Warning Label
DO NOT PUMP FLAMMABLE FLUIDS. DO NOT USE PUMP IN AN EXPLOSIVE
ENVIRONMENT. READ AND UNDERSTAND THE OWNER’S MANUAL COMPLETELY
BEFORE USING. RELIEVE SYSTEM PRESSURE BEFORE PERFORMING MAINTENANCE.
WARNING

Unpacking
8
Closely inspect all contents in the shipping carton.
If you have missing or damaged components, please contact Everflo Product Support at
1-800-864-1649
Plunger Pump
P/N EFHP2000
Regulator Assembly
Regulator: EF-792943
Quick Connect x 1/2” Hose barb (1)
P/N EF-QC-A12
*(1) Pre-installed on Regulator
Quick Connect Plug (2)
P/N EF-789160
*(1) Pre-installed on Pump
Quick Connect x 3/8” Elbow (1)
P/N EF-QC-EL38
*(1) Pre-installed on Regulator
Quick Connect x 1/2” Elbow (2)
P/N EF-QC-EL12
¼” MNPT Plug (2)
P/N F14
*(1) Pre-installed on Regulator

Assembly
9
Step 1 – Inlet Fitting Installation
Install (1) QC x 1/2” HB elbow fitting into the pump inlet port on the
bottom left side of the pump manifold.
Install (1) QC x 1/2” HB elbow fitting into the pump inlet port on the
bottom right side of the manifold.
oUse a flat blade screwdriver to remove QC clip from the pump before
installing fitting. Snap QC clip back into pump after fitting is inserted.
Note: The pump is configured for installing (2) QC x 1/2” HB elbow fittings
into the pump inlet ports on the bottom of the manifold. If preferred to
use only one pump inlet port, there is an extra QC plug in the manual
bag that can be installed to plug the desired port.
Tools Needed
Flat blade
screwdriver
Pump inle
t
QC x 1/2” Elbow
Inlet fitting
QC Clip
QC x 1/2” Elbow
Inlet fitting
Pump inle
t
QC Clip
QC Clip
Pump port
Insert screw-
driver here to
remove QC clip

Assembly
10
Step 2 – Plug or Optional Gauge Installation
Install either the 1/4” MNPT Plug or Optional Gauge into the 1/4” FNPT
port on the regulator.
oUse a wrench to thread the plug or gauge into the regulator port.
Tools Needed
Wrench
Regulator assembly
1/4” MNPT Plug Optional Gauge:
P/N 2141GXB300
Table of contents
Other Everflo Water Pump manuals
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual