EUROSTER 3000 – USER MANUAL 5
After selecting the mode, you can press key or wait for 10 seconds, then the thermostat
automatically set, the day and time to SUDAY, 0:00, shows the current room temperature.
APPLICATION
This thermostat can be used for "Floor Heating System". This device should be installed and
serviced by a qualified technician, and make sure that power has been disconnected before
installation.
The floor sensor cable should be installed to the terminal block No. 1 and No.2 (The floor
sensor cable is an optional accessory).
When installation is correctly done, set the thermostat on the base, then reset the thermostat
by pressing the "Reset" button, the thermostat will automatically check if the floor sesor is
installed and read the room temperature.
Note: It is not necessary to have the floor sensor installed when fitting with a non-floor heating
system.
Atte tio !
If the floor sensor cable is not installed, floor temperature detecting function will not be able to
use. Whenever the cable is installed, reset the thermostat by pressing the "Reset" button. This
will activate the floor temperature detecting function immediately.
There are two operation modes can be selected:
1. Room temperature mode.
The thermostat will ignore the reading from floor sensor. In this mode, the temperature of the
room will determine whether the heating system is activated.
2. Floor temperature mode.
In this mode, the thermostat will continuously compare the floor and room temperatures to the
preset temperature setting. When these temperatures are reached, then the thermostat will
automatically turn off the heating system.
Now the thermostat you have purchased is floor heating control type, which simply means it
has a built in floor temperature set and can change it's temperature setting.
You have two choices to set floor heating control mode
a) If the user selects FL: mode, the unit will control the N/ FF of the HEATNG via air
sensor, it will not concern the detection of floor sensor.
b) If the user selects FL: A mode, the unit will control the N/ FF of HEATING via both of
floor and air sensor. Here the setting range of floor sensor is 10ºC ~ 45ºC .
There are two conditions to turn on the heating:
●Floor temperature is lower than the floor sensor setting
●Air Temperature is lower than the air sensor setting
(In any of this conditions is fulfilled, the thermostat will turn on the heating)
There are two conditions to turn off the heating:
●Floor temperature is higher than floor sensor setting.