eTIGER ES-D5B User manual

ES-D5B
Wireless Smoke Detector
EN 14604

2

3
Contents
Introduction . . . . . . . . . . . . . . 4
Box Content . . . . . . . . . . . . . . 4
Specications . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . 5
Connect the ES-D5B to your alarm system . . . . . . . . . 5
Operating test . . . . . . . . . . . . . . . . . 6
Mounting . . . . . . . . . . . . . . . . . . 6
Care . . . . . . . . . . . . . . . . . . . . 7
Installation guidelines . . . . . . . . . . . 8
Useful indications . . . . . . . . . . . . . . . . . . . 8
Optimal installation . . . . . . . . . . . . . . . . . . 8
Warning: unsuitable installation . . . . . . . . . . . . . . 11
Standards . . . . . . . . . . . . . . . 14
EN
Images, illustrations and text are non-contractual. ETIGER and the ETIGER logo are
registered trademarks and the property of ETIGER.
Copyright © 2019 ETIGER. All rights reserved.

4
LED indicator Test button
Introduction
This photoelectric smoke detector is designed to detect smoke
anywhere the detector is installed. It does not detect gas, heat or
ames. This smoke detector is designed to inform you in case of
start of re thanks to its built-in siren. It enables you to save precious
time and evacuate your house before the re spreads. However,
this smoke detector can only send an alert if located, installed, and
taken care of according to the instructions in this user manual.
Box Content
- ES-D5B x1
- Mounting bracket x1
- AA 1.5V batteries x2
- Documentation

5
Specications
- Internal antenna
- Radio-frequency: 433 MHz
- Transmission distance: ≥ 100 m (in open area)
- Smoke sensitivity: 0.09 ~ 0.16dB/m
- Volume: >85dB (at 3 m)
- Current (standby): <4 uA
- Current (operating): <40 mA
- Heat sensitivity: 54 ~ 70°C
- Powered by 2 x AA 1.5V battery (included)
- Battery life: ≥ 1 year
- Certication: EN 14604-2005
- Dimensions: Ø120 x 35.5 mm
-Reference: ES-D5B | Model: GS558
Installation
Install the batteries
Remove the back plate from
the detector by turning it
counterclockwise
Insert the batteries according to
the specications on the device.
Make sure to respect polarity !
EN

6
Connect the ES-D5B to your alarm system
Switch to Connection Mode on the control panel. Press and hold the
test button on the detector for 3 seconds. The control panel beeps
once: the detector is registered. If you hear two beeps, the detector
has already been connected.
Remark
For a continual protection of your home, the detector is assigned
to the 24h zone as per default settings. In case of low battery, the
detector will beep once every 40 seconds.
The detector is working: make sure the LED blinks once every 40
seconds. If so, the detector is in normal detection mode. When the
smoke detector triggers an alarm, the alarm will not stop until the
air is smoke-free again.
Operating test
Press and hold the test button for 6 seconds. The detector beeps 3
times every second, the LED indicator blinks fast and sends a signal
to the alarm system. To make sure the detector is working properly,
it is recommend to run this test once every six months.
52 mm
106 mm

7
Mounting
Make sure you have read carefully the instructions for optimal and
unsuitable installations before mounting the detector.
Select a suitable location (generally speaking, place the detector
at the center of the ceiling of the detection area) and screw the
mounting bracket to the selected location (see drawing below).
The detector is a small device that shall not be opened.
Insert the battery in its compartment and turn the plastic cover
clockwise. Press the test button and make sure the detector can
work properly.
Care
It is recommended to open the cover and remove the dust in the
detector’s smoke chamber at least once a year.
Remove the battery before cleaning the detector. Remove the dust
with a vacuum cleaner (attached to a soft brush). Carefully remove
dust in the detector components, especially in the openings of the
smoke chamber. Hand-wash the cover with a cloth dampened with
clean water and dry it with a lint-free cloth. Do not let any water in
the detector components.
Once your detector is clean, replace the battery, and close the cover.
Test the detector after cleaning.
EN

8
Installation guidelines
Smoke detectors must be installed according to the European
standard CE EN 14604. For a complete coverage of your home, the
detectors must be installed in every room, storage area, cellar, attic
and corridor. The minimum number of detectors to be installed is
one on each oor, one in every bedroom and one in the attic.
Useful indications
- Install one detector in every corridor next a bedroom room, as
shown in gure 1. In homes with two bedrooms, it is necessary to
install two detectors, as shown in gure 2.
- If your house or apartment has several oors, install a detector on
each oor, as shown in gure 3.
Optimal installation
We recommend a complete coverage and the use of additional
smoke detectors.
- Install a minimum of two smoke detectors for any type of home
- Install a detector in every bedroom
- Install a smoke detector at each end of a corridor giving access to
bedrooms, if this corridor is more than 12-meter long
- Install a detector in every room with a door that can be used as a
bedroom: smoke might be blocked by the door and the siren in the
corridor might not be loud enough to wake the person up if the
door is closed.

9
EN
Figure 1
Locations of
smoke detectors in
individual houses
with one bedroom
Smoke detectors for basic safety
Smoke detectors for optimal safety
Figure 2
Locations of smoke
detectors in single-
oor houses with
several bedrooms
Figure 3
Locations of smoke detectors in a mutlioor
house
Smoke detectors for basic safety
Dining room Kitchen
Living room
Bathroom
Bedroom
Living room Kitchen
Dining room
Bedroom
Bedroom
Bedroom Bedroom
Bedroom
Basement
Kitchen Living room
Bathroom Toilets
Toilets

10
- In the cellar, install the detectors near the stairs
- On the second oor, install a detector at the top of the stairwell
leading from the rst to the second oor.
- Make sure no door nor any obstacle will prevent the smoke from
reaching the detector
- Install additional detectors in your living room, your dining room,
in the common area, the attic and in the storage areas or in the
laundry room
- Install the smoke detectors as close as possible to the center of
the ceiling. If it is not possible, install the detector at the ceiling,
minimum 10 cm from the wall, as shown in gure 4.
- If you cannot install the detector at the ceiling and wall-mount is
authorized by the laws in your country, install the detectors 10 to 15
cm from the ceiling as shown in gure 4.
- If you have no choice but installing the detector on a sloped ceiling,
try to install the detector at a horizontal distance of 1 m from the
top of the ceiling, as shown in gure 5.
minimum
10 cm
Ceiling
Wall
maximum
15 cm
Optimal location
Acceptable location
Figure 4
Optimal and acceptable locations
for smoke detectors
center of
the ceiling
Other manuals for ES-D5B
1
This manual suits for next models
1
Table of contents
Languages:
Other eTIGER Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

System Sensor
System Sensor DH500ACDC Installation and maintenance instructions

Resolution Products
Resolution Products RE612 CryptiX quick start guide

First Alert
First Alert PC900V user manual

Eminent
Eminent EM6590 E-Domotica user manual

Ei Electronics
Ei Electronics Ei Ei168RC user manual

Carrier
Carrier Kidde Quell Q301 user manual