enware ENM620 Assembly instructions

Call 1300 369 273
www.enware.com.au
Enware Australia Pty Limited
9 Endeavour Rd Caringbah NSW 2229 Australia
Ph: +61 2 8556 4000 info@enware.com.au
I00271_Jan 21
Installation, Operating & Maintenance Instructions
Enware Touch Free Sensor Tap
ENM620/ENM621
AUTO SENSE SYSTEM
ON DEMAND SENSOR SYSTEM
The Bluetooth® trademark and logos are property of Bluetooth SIG, Inc., and their usage is licensed for Orasgroup.

2 Call 1300 369 273 www.enware.com.au
PRODUCT COMPONENTS FRONT OF WALL
OR
BATTERY OPERATED
ON DEMAND SENSOR
Sensor above outlet
On Demand Sensor Front of Wall Component Only
230mm Fixed Spout with Laminar Flow - Battery Operated
ENMWB C2L3 - 8Lpm
ENMWB C2L5 - 6Lpm
ENMWB C2L6 - 4.5Lpm BATT
AUTO SENSE
Sensor below outlet
Auto Sense Front of Wall Component Only
230mm Fixed Spout with Laminar Flow - Battery Operated
ENMAB C2L3 - 8Lpm
ENMAB C2L5 - 6Lpm
ENMAB C2L6 - 4.5Lpm BATT
MAINS POWERED
ON DEMAND
Sensor above outlet
On Demand Sensor Front of Wall Component Only
230mm Fixed Spout with Laminar Flow - Mains Powered
ENMWM C2L3 - 8Lpm
ENMWM C2L5 - 6Lpm
ENMWM C2L6 - 4.5Lpm
MAINS
AUTO SENSE
Sensor below outlet
Auto Sense Front of Wall Component Only
230mm Fixed Spout with Laminar Flow - Mains Powered
ENMAM C2L3 - 8Lpm
ENMAM C2L5 - 6Lpm
ENMAM C2L6 - 4.5Lpm MAINS
Also available with 200mm spout:
ENMWB C1L3 - 8 Lpm
ENMWB C1L5 - 6 Lpm
ENMWB C1L6 - 4.5 Lpm
BATT
Also available with 200mm spout:
ENMAB C1L3 - 8 Lpm
ENMAB C1L5 - 6 Lpm
ENMAB C1L6 - 4.5 Lpm
BATT
Also available with 200mm spout:
ENMWM C1L3 - 8 Lpm
ENMWM C1L5 - 6 Lpm
ENMWM C1L6 - 4.5 Lpm
MAINS
Also available with 200mm spout:
ENMAM C1L3 - 8 Lpm
ENMAM C1L5 - 6 Lpm
ENMAM C1L6 - 4.5 Lpm
MAINS

www.enware.com.au Call 1300 369 273 3
PRODUCT COMPONENTS IN WALL
BATTERY
OPERATED
ENM620
6V Battery
Operated
In-Wall
Component
MAINS POWER
ENM621
12V Mains Power
In-Wall
Component
BATT
MAINS
NOTE WHEN PLACING AN ORDER
IN WALL
(back of wall)
component
is ordered
separately to
FRONT OF
WALL
component
Battery operated
IN WALL
(back of wall)
component
MUST be paired
with battery
operated
FRONT OF WALL
Mains operated
IN WALL
(back of wall)
component
MUST be paired
with mains
operated
FRONT OF WALL
Sensors will not operate if components are not paired correctly
BATT
MAINS

4 Call 1300 369 273 www.enware.com.au
CONTENTS
PRODUCT COMPONENTS FRONT OF WALL PAGE 2
PRODUCT COMPONENTS IN-WALL PAGE 3
TECHNICAL INFORMATION PAGE 5
INSTALLATION COMPLIANCE PAGE 7
INSTALLATION PROCEDURE - IN-WALL PAGE 8
INSTALLATION PROCEDURE - FRONT OF WALL PAGE 11
OPERATING INSTRUCTIONS PAGE 15
THERMAL DISINFECTION PROCEDURE PAGE 17
SERVICE AND MAINTENANCE PAGE 18
SENSOR PROGRAM PAGE 24
TROUBLESHOOTING PAGE 27
PRODUCT WARRANTY PAGE 28
Enware Touch Free Sensor Tap
ENM620/ENM621

www.enware.com.au Call 1300 369 273 5
237(230mm spout)/
205 (200mm spout)
30°
174
219(230mm spout)/
190(200mm spout)
190
310
190
310
AUTO SENSE ON DEMAND
SENSOR
6 THRU TYP
105.7
138.0
180.7
213.0
73.2 73.2
106 106
190
(FLANGE DIMENSION)
310
(FLANGE DIMENSION)
127.5
95
1/2" (BSP)
INLET
320
66.2
286
(BLOCKOUT)
27.7
362
15 mm
IN WALL ADJUSTMENT
TRIM DOWN BOX COVER
TO SIZE AFTER INSTALLATION
79.5
1/2" (BSP) OUTLET
180
221
7.7
166
(BLOCKOUT)
42.5
32.5
FRONT OF WALL COMPONENTS
IN WALL COMPONENTS

6 Call 1300 369 273 www.enware.com.au
* In accordance with AS/NZS3500. Enware products are to be installed in accordance with the Plumbing Code of Australia
(PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS3500 may void the product and performance warranty
provisions.
** Heated Water Supply AS/NZS3500.4. All heated water installations for sanitary xtures used primarily for personal hygiene
purposes shall deliver heated water at a temperature not exceeding: a) 45°C for healthcare and aged care buildings, early
childhood centres, primary and secondary schools and nursing homes, or similar facilities for the aged, the sick, children, or
people with disabilities; and b) 50°C for all other situations.
INSTALLATION CONDITIONS
Dynamic Inlet Pressures*
For optimum operation it is recommended that the
hot and cold water supply pressures be balanced
within +/- 10%
Min. 20kPa
Max. 500kPa
Static Inlet Pressures
For testing purposes / system commissioning Max. 1000kPa
Maximum Water Temperature 70 °C
SENSOR PERFORMANCE
AUTO SENSE
Sensor Range
Adjustable to + / - 20%
250mm (default)
Water Run Time
After hands have moved from sensor range
Adjustable
2 seconds (±1)
Maximum Flow Period
Adjustable 2 minutes
ON DEMAND SENSOR
Sensor Range
Adjustable to + / - 20% 20-100mm
Water Run Time
After activation
Adjustable
15 seconds (±1)
default setting
TECHNICAL INFORMATION
The more
stars the more
water efficient
8litres per
minute
WATER RATING
www.waterrating.gov.au
The more
stars the more
water efficient
5.5
litres per
minute
WATER RATING
www.waterrating.gov.au
The more
stars the more
water efficient
4litres per
minute
WATER RATING
www.waterrating.gov.au
NOTE: Enware Australia advises:
1. Due to ongoing Research and Development, specications may change without notice.
2. Component specications may change on some export models

www.enware.com.au Call 1300 369 273 7
This product should be installed using the appropriate Standard, Code of
Practice and legislation applicable to each state and following the details
outlined in this section.
This product must be installed by a licensed plumber.
To ensure that the valve operates correctly, it is necessary that the pipework
is thoroughly ushed with clean water before it is installed as per AS/NZS
3500.1. This will remove any physical contaminants from the pipework,
ensuring trouble-free operation. During the ushing procedure care should be
taken to prevent water damage occurring to the surrounding area.
WARNING: Do not cut the electrical cable of the sensor tap,
or alter the product in any way to suit installation. Damage
caused in this way will void warranty.
Transformer with 4.5m Extended Cable (ENMS230) are available if
extra power cable length is required
INSTALLATION
INSTALLATION COMPLIANCE

8 Call 1300 369 273 www.enware.com.au
INSTALLATION PROCEDURE IN WALL
STEP 1
Determine the desired location for the box with relation to the spout height off the basin.
AUSHFG specifies the spout should be 1120mm off finished floor level.*
* Recommended height of spout (point of water discharge) for Type A and Type B Clinical
Hand Washing Bay is 1120mm off finished floor level when combined with basin at a height
of 865mm, according to AUSHFG (Australasian Health Facility Guidelines).
SET-OUT HEIGHTS
Suggested heights from finished floor:
Spout
outlet
1050mm
1120mm to point of water discharge
(Australasian Health Facility Guidelines)
Top of
basin
850mm
865mm (Australasian Health Facility
Guidelines)
800 - 830mm (Reference: AS1428.1-
2009)
IN-WALL COMPONENTS INSTALLATION PROCEDURE

www.enware.com.au Call 1300 369 273 9
INSTALLATION PROCEDURE IN WALL
STEP 2
If installing within a frame wall, fit mounting
timber in the desired location for Box support.
Enware recommends 13mm ply wood fixed
between two vertical in-wall studs.
Important: The depth of Box from finished wall
to the back of the Box must be between 80mm
- 95mm.
STEP 3
Mark out the fixing point locations while
ensuring the box is level, and secure the box to
the ply wood support using the external fixing
lugs and adequate fixing screws.
STEP 4
Remove box front cover. Keep the front cover
and 4 screws at hand.
STEP 5
Purge water supply line to make sure all debris
has been cleared.
Connect water supply to inlet fitting using a 1/2”
BSP loose-nut connector.
Note: Use a loose-nut connector (#62) or union
for connection to inlet, to allow for easy removal
of the valve should there be any need to repair
or service the components in future.
66
15 MM
IN WALL ADJUSTMENT
TRIM DOWN TO SUIT
AFTER INSTALLATION
MIN 80
MAX 95
G1/2" (BSP)
INLET CONNECTION

10 Call 1300 369 273 www.enware.com.au
INSTALLATION PROCEDURE IN WALL
STEP 6
Make sure integral inlet isolation valve is off. The
line of the slot should be horizontal across the
inlet valve.
STEP 7
Turn on the water supply and test the supply
pipeline connection for leaks.
Do not turn on the integral isolation valve yet.
STEP 8
Note – this step is for 12V mains powered
installations only:
Plug the transformer into a power outlet, and
place the end connector of the 12V transformer
in the Box via the cable access hole, which is
located on the top side of Box.
Ensure at least 50mm of cable is available in
the Box to connect to the sensor. If the cable is
not long enough, use an extended transformer
(4.5m - ENMS230 - available from Enware).
Use a conduit to run the transformer cable
between the power point and the box, to allow
for easy component replacement in future.
WARNING: Do not cut the electrical cable
of the sensor tap, or alter the product in any
way to suit installation. Damage caused in
this way will void warranty.
To avoid damage to the cable when trimming
the Box front cover later, ensure the cable is
tucked away towards the back of the box.
STEP 9
Re-fit the Box front cover and secure with 4
screws.
STEP 10
The wall is ready to be sheeted. Make sure the
sheeting is finished hard against the protruding
section of the Box.
ISOLATION VALVE
Other manuals for ENM620
1
This manual suits for next models
1