456
WARRANTY INFORMATION
TROUBLESHOOTING
This device is warranted to be free of material and workmanship defects for 2 years from the
date of purchase. Original receipt or proof of purchase from an authorized retailer must be
presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc.
Warranties from other Enerlites products may vary. This warranty is nontransferable and
does not cover normal wear and tear or any malfunction, failure, or defect resulting from
misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent
permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end
user customer of Enerlites products for direct, indirect, incidental, or consequential damages
even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability
under this or any other warranty, express or implied, is limited to repair, replacement or
refund. Repair, replacement or refund are the sole and exclusive remedies for breach of
warranty or any other legal theory.
© 2016 Enerlites Inc.
CA, U.S.A.
0207160027
1.
Push Manual On/Off Button, if the load turns On; verify that the Range
dial is on high.
2.
Check the wiring connections.
3.
Switch may be in VACancy mode. Select the OCC position on the Mode
Switch if "Auto ON" is what's desired.
NOTE: There is a 3 minute warm-up time at initial power-up.
The load may turn on/off several times during the warm-up.
The Load does not turn On. LED does not flash regardless of motion:
The Load does not turn On when LED indicator flashes and motion is
detected:
1.
Push Manual On/Off Button, if the load turns On; verify that the Range
dial is on high.
2.
Check the wiring connections. Be sure the LOAD wire is connected.
3.
Switch may be in VACancy mode. Select the OCC position on the Mode
Switch if "Auto ON" is what's desired.
4.
The light level might not be properly set. Follow the Ambient Light Level
Adjustment instructions on previous page to program.
1.
Motion may be detected. The time delay constantly restarts its countdown
after the last motion detected. To verify proper operation, turn the Time
Delay Knob to 15s (Test Mode) and make sure there is no motion (no LED
flashing). Tape may be used to cover the fresnel lens while testing.
2.
Check for significant heat source emitting within six feet (two meters) such
as high wattage light bulb, portable heaters or HAVC vents.
3.
Check the wiring. Make sure the HOT and LOAD wires aren't reversed.
The Load does not turn Off:
1.
Motion may be detected. The time delay constantly restarts its countdown
after the last motion detected. To verify proper operation, turn the Time
Delay Knob to 15s (Test Mode) and make sure there is no motion (no LED
flashing). Tape may be used to cover the fresnel lens while testing.
2.
Check for significant heat source emitting within six feet (two meters) such
as high wattage light bulb, portable heaters or HAVC vents.
3.
If Manual operation of push-button is desired, select VAC mode on the
Mode Switch.
4.
If the sensor is installed in a small room, turn the Range dial lower to avoid
false or unwanted detection from open window or door.
The Load turns on when its not desired:
OPERATION
AUTO Mode: To use this mode, the Time Delay must not be in Test Mode.
In AUTO Mode, the sensor automatically sets the time delay between 7 to 30
minutes based on occupancy patterns. When the ambient light level is
reached, the Load will automatically turn ON when motion is detected and
automatically turn OFF when the selected time delay has expired.
•Walk-Through Feature: A "Walk-Through" is when motion is detected
for a brief moment of 30 seconds and not again for 2.5 minutes. When
a "Walk-Through" is detected, the Load is automatically turned OFF
after 2.5 minutes. If motion is detected after the initial 30 seconds, the
automatic time delay starts.
OCCupancy position: When the ambient light level is reached, the Load will
automatically turn ON when motion is detected and automatically turn OFF
when the selected time delay has expired.
VACancy position: The Load will turn ON ONLY when the push button is
used and automatically turns OFF when the selected time delay has expired.
If the time delay has expired and the Load turns OFF, the Load will turn ON
again automatically if motion is detected within 30 seconds.
Mode Switch: AUTO/ OCCupancy/ VACancy
OCC
Mode
AUTO
VAC
Description
Occupancy Mode:
Automatic On, automatic Off
after set time delay.
Position
Left
Center
Right
Vacancy Mode: Manual On only,
automatic Off after set time delay.
Push-Button Function
Manually toggles
Manually toggles
On / Off the load.
On / Off the load.
Manually toggles
On / Off the load.
Auto Set Occupancy Mode:
Automatic On ,Automatic Off after
digital auto set delay time,
including walk-through Mode
Manual ON/OFF Button: In AUTO, OCC, or VAC mode, The push button
may be used to manually turn ON/OFF the load and time delay will take
effect. There is a 5 seconds reset delay after each push of the button to
trigger the ON/OFF.
Figure 5