Elmi DOS-20M User manual

User manual
Digital orbital shaker DOS-20M
ELMI Ltd.
21-133 Aizkraukles Str.
Riga, LV-1006, Latvia
T.: +371 67558743
T.: +37167551934
E: [email protected]om
W: www.elmi-tech.com

1
Page
Introduction.............................................................................................................................................1
Technical specifications........................................................................................................................ 2
Delivery package...................................................................................................................................2
Safety.......................................................................................................................................................3
Preparation to use.................................................................................................................................. 3
The device.............................................................................................................................................. 4
Control description................................................................................................................................. 5
Using the device(mainmenu).............................................................................................................. 6
Orbitalrotationmode.............................................................................................................................. 7
Auto reversemode.................................................................................................................................7
Reciprocal mode.................................................................................................................................... 8
Vibration mode...................................................................................................................................... 8
Programming menu......................................................................................................................... 9-10
Additional modes.................................................................................................................................11
Disinfection and cleaning....................................................................................................................12
Transportation and storage................................................................................................................12
Warranty statements ...........................................................................................................................12
Certificate of approval.........................................................................................................................13
Certificate of sale.................................................................................................................................13

2
Dear user!
Congratulations, you have acquired an ELMI shaker - product of advanced technology and
high quality!
DOS-20M shaker is easy to use and reliable in operation. We ask you to carefully read the user
manual and observe all maintenance and operation requirements, as this will ensure long and
flawless use of the device.
The shaker is designed to mix up components in different kind of test tubes, flat bottom laboratory
dishes , flasks, Petri dishes, etc.
Technical specifications
Sizeofworkingplatform,mm 355х235
Speed of rotation, RPM 10-300
Amplitude of platform movement, mm 20
Maximumload,kg 5
Working modes 4
Type of platform movement orbital
Timer, 1 minute –9 hours 59minutes
Environmental temperature, °C +4 up to +45
Relative moisture of atmosphere ( at 20°C temperature) not more than 80%
Voltageandfrequency 110-220 V, 50-60Hz
Powersupplyadapter: 24VDC –1A
Maximal power consumption, W 24
Size of the device, mm 360х280x100
Netweight,Kg 6,3
Delivery package
Item Quantity
Shaker.............................................................................................................................................................1
Power supply adapter ...................................................................................................................................1
Magnetic clips................................................................................................................................................6
Usermanual...................................................................................................................................................1
Packaging.......................................................................................................................................................1

3
General safety
•Use only as directed in the operating instructions provided.
•The unit should not be used if it has encountered a physical shock or has beendropped.
•The unit must be stored and transported in a horizontal position (see package label).
•After transport or storage allow the unit to dry out (2-3 hrs) before connecting to mainspower.
•Use only original accessories provided by the manufacturer and ordered
specifically for this model.
Electrical safety
•Connect to the mains only with a voltage corresponding to that on the serial number label.
•Ensure that the switch and plug are easily accessible during use.
•Do not plug the unit into the main outlet without grounding, and do not use extension lead without
grounding.
•Before moving the unit, disconnect it from the mains. Toturn off the unit, disconnect the power plug
from the mains outlet.
•It is the user's responsibility to carry out appropriate decontamination if hazardous material is spilt on
or inside the equipment. If liquid is split inside the unit, disconnect it from the mains and have it
checked by a competent person. During operation
•Do not block the platform movement.
•Do not leave the operating unit unattended.
•Do not operate the unit in environments with aggressive or explosive chemicalmixtures.
•Do not operate the unit if it is faulty or been incorrectly installed.
•For indoor use only.
•Before using any cleaning or decontamination method except those recommended by the manufacturer,
check with the manufacturer that the proposed method will not damage theequipment.
•Do not make modifications to the unit.
Biological safety
•It is the user's responsibility to carry out appropriate decontamination if hazardous material is spilt
on or inside the equipment.
Preparation to use
•Unpack the device. Please keep the packaging material for transportation or storagepurposes.
•If the machine was stored at a temperature below 0°C, make sure that it is kept at room
temperature for at least two hours before turning it on.
•Place the shaker onto a level, horizontal surface.
•Examine the power adapter and appearance of device for damage.
•Connect the power cord to the centrifuge, insert the adapter in to the socket and press network
switch at ( I ) symbol. Display will light up on the control panel.
•Check the platform. Try rotating it by hand. There should be no noise or obstacles to smooth
running.
•Check the surrounding of device. Safety distance of 30cm must be observed around the device
during operation.
•Check for other signs of damage or malfunction.
ATTENTION! If there is any apparent damage or malfunction, DO NOT TURN ON the shaker
without consulting a specialist.

4
1 - Network switch
2 - Power plug
3 - Working platform
4 - Casing
5 - Control panel
3
4
1
2
5

5
Control panel
Up and down navigation keys
Left, right navigation keys
and increasing, decreasing parameter value keys
Entering and exiting key in programming mode
to set the step parameter
Start stop key
Setting key to manage the interface of device
Entering and exiting key to programming mode

6
Main menu
In the main menu you can choose and set the needed
working mode.
Choosing the working mode
The shaker has 4 working modes:
1) Orbital rotation
2) Auto reverse
3) Reciprocal
4) Vibration
To choose a mode go to the lowest level of the main menu and
select the desired mode using the right or left navigation keys.
Adjusting the parameters of the mode
Using the navigation keys, select the desired mode and
set required values for each parameter.
Press and hold the left or right navigation key to quickly
change the value of a parameter.

7
Orbital rotation mode
Orbital rotation - clockwise classic platform motion mode
with adjustable speed and time parameters.
mode parameters:
TIMER: 1 minute - 99:59 minutes - continuous mode.
PRM: 15 - 300.
Auto reverse mode
Auto reverse mode - platform orbital motion mode with set and equal numbers of
clockwise and counter-clockwise turns.
Adjustable RPM, time and the number of one-way rotations.
Options:
TIMER: 1 minute - 99.59 minutes - continuous mode.
PRM: 15 RPM - 300 RPM.
TURNS: 5 - 25.

8
Reciprocal mode
Reciprocal mode - provides changing direction motion with the choice
of rotation angle of the platform,
at a predetermined RPM and operating time.
Options:
TIMER: 1 minute - 99.59 minutes - continuos mode.
RPM: 07 - 20.
Angle: 10 ° - 360 °
Vibration mode
Vibration mode - reciprocating type of movement of the platform
imitating shake.
Ability to customize the speed settings, time and amplitude of the shake-up.
Options:
TIMER: 1 minute - 99.59 minutes - continuos mode.
PRM: 07 - 20.
Amplitude: 1mm - 2mm

9
Programming menu
You can create a custom program using the programming
menu. Create multiple steps to combine the various
shaker working modes.
To enter and exit the programming menu use the “Cycles
mode” key.
Creating program
program step
working mode type indicator
number of cycles
total program time
You can set the number of repeat cycles on the bottom line of
the programming menu. Ranges are from 1 to 99, or continuos
mode can be used. Create a custom cycle program by adding
four steps and a number of program repeat cycles as required.
All settings are made using the navigation keys. Enter and
exit the programming step using "ENTER" key.
When setting the programming, you can assign the
desired operating mode:
1) Orbital rotation mode
2) Auto reverse mode
3) Reciprocal mode
4) Vibration mode
5) Pause
6) Disable step
The number of repeat cycles can be set in the bottom line
of programming main menu, ranges are from 1 to 99,
plus continuos mode.
Table of contents
Other Elmi Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

Agilent Technologies
Agilent Technologies 5800 ICP-OES user guide

Endress+Hauser
Endress+Hauser Cleanfit CPA875 operating instructions

NI
NI PXI-5422 CALIBRATION PROCEDURE

Collomix
Collomix Aqix operating instructions

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series operating manual

Ocean Insight
Ocean Insight FLAME-NIR+ Installation and operation manual

Parker
Parker ALIGN-MG-NA Installation, operation and maintenance manual

BD
BD 644787 user guide

DENTAURUM
DENTAURUM Compact Megaplus Instructions for use

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 instruction manual

VWR
VWR SAS Super IAQ instruction manual

illumina
illumina MiSeqDx reference guide