Elko RFTC-50/G User manual

RFTC-50/G
°C
E
N
Wireless temperature
controller

- 2 -
Contents
3
4
5
6
7
8
9
10
11
12
14
18
Warning .........................................................................................................
Characteristics ..............................................................................................
Technical parameters ...................................................................................
Battery replacement .....................................................................................
Description of device ....................................................................................
Description of display ..................................................................................
Description of control...................................................................................
Selecting the heating mode.........................................................................
Setting the temperature for manual mode ................................................
Entering the programming menu................................................................
Entering the settings menu..........................................................................
Example of programming the RFTC-50/G ...................................................

- 3 -
E
N
Warning
Instruction manual is designated for mounting and also
for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by
a person with adequate professional qualication upon
understanding this instruction manual and functions
of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on
transportation, storing and handling. In case you notice
any sign of damage, deformation, malfunction or
missing part, do not install this device and return it to
its seller. It is necessary to treat this product and its parts
as electronic waste after its lifetime is terminated. Before
starting installation, make sure that all wires, connected
parts or terminals are de-energized. While mounting and
servicing observe safety regulations, norms, directives
and professional, and export regulations for working
with electrical devices. Do not touch parts of the device
that are energized - life threat. Due to transmissivity of
RF signal, observe correct location of RF components
in a building where the installation is taking place. RF
Control is designated only for mounting in interiors.
Devices are not designated for installation into exteriors
and humid spaces. The must not be installed into metal
switchboards and into plastic switchboards with metal
door - transmissivity of RF signal is then impossible,
do not use in areas aected by high-frequency
interference. RF Control is not recommended for pulleys
etc. - radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can
get at etc. and thus disable remote control.

- 4-
Characteristics
- the temperature controller RFTC-50/G is used as a simple solution for controlling temperature in a room or the home
- the RFTC-50/G is a programmable temperature controller with the option of setting a weekly program, which oers two
regulation options:
a) the internal sensor scans the temperature, and based on the set command, it gives the command to switch on the
switching actuator RFSA-6x, RFUS-61 or RFSC-61. This can be used mainly to control temperature of heaters, hall
panels, convection heaters, etc.
b) the internal sensor scans the temperature, and based on the set command (weekly program), it switches on the
actuator RFSTI-11B, which also scans the critical oor temperature (this occurs to prevent damage when opening a
window). This solution is especially suitable for underoor heating.
- control is performed using buttons, individual symbols (temperature, battery, mode, etc.) are displayed on a backlit LCD display
- the controller is powered by: batteries - 2 x AAA 1.5 V
- the at rear side of the device enables its placement anywhere in the room where you wish to measure temperature
- the LOGUS90 frame design oers a luxurious design (glass, wood, stone, metal) with the option of placing it in multiple frames

- 5 -
E
N
Technical parameters
Supply voltage:
Battery life:
Temperature oset:
Temperature oset range:
Display:
Backlight:
Transmission / function indicator:
Temperature measurement input:
Temp. meas. range and accuracy:
Frequency:
Signal transmission method:
Minimum control distance:
Range in open area:
Other data
Max. number of controlled actuators RFSA-6x:
Operating temperature:
Operating position:
Mounting:
Protection:
Electromagnetic radiation degree:
Dimensions
Frame - plastic:
Frame - metal, glass, wood, granite:
Weight:
Related standards:
2 x 1.5V bat. AAA
up to 1 year (depending on number of controlled actuators)
2 buttons v / ^
± 5 °C
LCD, characters
Yes, active - blue
symbols
1x internal sensor
0 .. + 55 °C; 0.3 °C of scale
866 MHz, 868 MHz, 916 MHz
bidirectionally addressed message
20 mm
up to 100 m
4
0 .. + 55 °C
wall
gluing / screwing
IP20
2
85 x 85 x 20 mm
94 x 94 x 20 mm
66 g (without batteries)
EN 60669, EN 300 220, EN 301 489 directive R&TTE Directive,
Order. No 426/2000 Coll. (Directive 1999/EC)

- 6 -
°C
+
-
+
-
Battery replacement
Placement
Do not expose it to sharp temperature changes, direct sunlight or excessive moisture. Place the temperature units so that
they are not near windows or heating equipment, etc., which could inuence the internal temperature sensor.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
Prior to rst assembly, remove the moldings in the frame and peel
o the protective lm from the display.
After inserting the batteries, all features for controlling the display
function illuminate for 2 seconds, then the FW version is displayed
in the upper row.

- 7 -
°C
E
N
Day of the week
Heating mode
Current temperature
Control button
Current time
Circuit status
Control button ^
Hidden button
Description of device

- 8 -
0 6 12 18 24
Prog AM
°C
°F
Auto PM
Description of display
Display of the day of the week
Current time
in selected
format 12/24
Automatic mode
Battery status indicator:
A symbol is displayed when the batteries are
running low. The dead battery indicator shows that
the voltage is insucient for reliable communication
with a paired actuator(s).
- setting the time
- locking the menu item or program
- manual mode
- setting the temperature
- output switched on when selecting heating function
- output switched on when selecting cooling function
- displays in the case of low battery voltage
- vacation mode
- constantly illuminated - connection with all actuators successful
- ashing - connection successful only with certain actuators
- not illuminated - connection unsuccessful with all actuators
Mode switched o
- not illuminated
Auto
,
,

- 9 -
^
^^
^
^
^
°C
E
N
Description of control
Button functions for controlling:
Short press of buttons
^
^
(< 2 s)
- switching menu items, changing value
Long button press ^(> 2 s)
- unlocking the menu item or time program for changing
- conrmation of changed value after setting and locking of the menu item
or program
Long button press
^
(> 2 s)
- refusal of changed value, return to original value and locking of the menu
item or program
Short press of hidden button (< 2 s)
- closing menu - after closing the menu communication with actuators is performed
- the default display indicates the update of the actuator status (e.g. upon actuator
power failure)
Long press of hidden button (> 2 s)
- upon default display entry to the menu

- 10 -
Auto
°C
^ ^ ^
^^
^
^
Selecting the heating mode
- manual mode
- the thermostat
regulates to the
temperature set for
the manual mode
without a time program
- vacation mode -
the thermostat regulates
to a temperature set
for the vacation mode,
after the vacation mode
period expires, the
heating mode is reset
that had been selected
prior to switching on the
vacation mode
Auto - automatic mode -
the thermostat regulates
to a temperature based
on the set time program,
outside of time segments
in the program it
regulates to the reduced
temperature set in the
menu ProG, item ECO
OFF - thermostat switched
o - when selecting the
function„heating “, the
thermostat regulates to a
non-freezing temperature
set in the menu in the item
OFF, when selecting the
function„cooling “ the
thermostat is switched o
and is not performing any
regulation
At the default display, press and hold the button ^. In the upper row of the display, the indicator rEG appears and the symbol
of the currently chosen heating mode ashes, or the indicator OFF appears. Now by shortly pressing the buttons
^
^
you
can select the heating mode. Conrm the heating mode selection by pressing and holding the button ^.
You can return to the original mode by pressing and holding
^
.
This also brings you to the initial display.
Other manuals for RFTC-50/G
2
Table of contents
Other Elko Temperature Controllers manuals

Elko
Elko RFTC-50/G/ice User manual

Elko
Elko RFTC-50/G User manual

Elko
Elko iNels RFTC-10/G User manual

Elko
Elko RFTC-50/G User manual

Elko
Elko iNELS RF Control RFTC-150/G User manual

Elko
Elko iNELS RFTC-150/G User manual

Elko
Elko RFTC-150/G User manual

Elko
Elko iNels RFTI-10B User manual

Elko
Elko iNELS RFTI-10B User manual

Elko
Elko iNels RFSTI-11/G User manual
Popular Temperature Controllers manuals by other brands

SMC Networks
SMC Networks Thermo-con INR-244-639 Operation manual

eltherm
eltherm Ex-TC It Series operating instructions

Omron
Omron C200H-TV Series Operation manual

industrie technik
industrie technik CA1 instructions

KRAL
KRAL EET 32 operating instructions

dixell