elco EKO07042 User manual

MS18535
Flush/Surface Mount
Single-Load 360° PIR
Occupancy Sensor
USER MANUAL
CAT.NO.
EKO07042
OCCUPANCY
SENSOR
en

2
EKO07042 Occupancy Sensor
Rated Voltage 230 V ~ 50/60 Hz
Load
Lux
Adjustment
Auto off time
adjustment
Detection
Range
Operating
Temperature
Environmental
Protection
Load(L ) for Lighting:
Incandescent Lamp: max. 2000 W
AC Halogen Lamp : max. 1000 W
LV Halogen Lamp : max.1000 VA
Fluorescent Lamp : max. 900 VA
LED Lamp
: max.100 W
(max.4 lamps)
From 5 s to 30 min, Test &
From 10 Lux to 2000 Lux
360°circular, up to 7m at height of 2.5 m
(20 - 25 °C)
0 °C to +40 °C (Indoor usage)
Class
IP44 (Surface mount withjunction box)
IP40 (Flush mount with spring clip or
European standard junction box)
TECHNICAL SPECIFICATIONS
Protection 10 A circuit breaker
-20 °C to +40 °C (Outdoor usage) (see below)
en
en

3
EKO07042 Occupancy Sensor
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC
FLASH
Safe electrical installation must be carried out only by
skilled professionals. Skilled professionals must prove
profound knowledge in the following areas:
•Connecting to installation networks
•Connecting several electrical devices
•Laying electric cables
•
•
•
Safety standards, local wiring rules and regulations
Failure to follow these instructions will result in
death or serious injury.
Safety Warning
High in-rush current can occur if certain bulb brands are
used and may cause permanent damage the unit.
NOTE
Do not mount the occupancy sensor on a conductive
surface, such as metal wallpaper.
Turn off power when change the light sources.
Make sure to always wire the sensor according to the
wiring diagram. Don't mix-up L (load) or L (live supply) with N.
Wrong connections will result in damage to the device.
Only open or repair the unit if you are a qualified electrician.•
en

EKO07042 is a ceiling flush mount or surface mount
occupancy sensor both applicable for indoor or outdoor application
which is ideal for use in office, conference room, hotel, home, etc.
With its Knobs, the time and Lux value can be adjusted as user
desired to match differentrequirements for switching light on and
off.
PACKAGE CONTENTS
1
PRODUCT DESCRIPTION
2.1 Features
2
Pattern
Quantity
Item
Pattern
Item
Sensor
1 1 1
User Manual
Protection Cap
Quantity
Non-dropping
screw
3 x 18mm
Wood Screw
4 x 25.4mm
Screw
Φ
3x 20
mm
Junction
Box
Rubber
washer
4 2 2 1
4
EKO07042 Occupancy Sensor
en

High performance relay for connecting all types of lights,
e.g. compensated / uncompensated fluorescent lamp,
halogen lamp, incandescent lamp,etc.
Flexible andwide mounting methods:Flush mount with
spring clip or European standard junction box, surface
mount with junction box isalso available.
High sensitivity is provided by a unique lens with "no
dead spot" zones in its 360° high intensity of detection.
A built-in red LED is used as an indicator for easy test
operation and different operation modes clear
identification.
Manually switch on the loads by wire connected to an
external N.C. type push button switch when the ambient
light level exceeds the pre-set Lux value.
EKO07042: 111.5 x 59 mm (See FIG. 1 -A)
Junction Box: 111.5 x 35 mm (See FIG. 1-B)
FIG.1-A
FIG.1-B
2.2 Dimension
5
EKO07042 Occupancy Sensor
en

3.1.1 It is recommended to install at the height of 2.5 m to
gain the optimal detection pattern. The detection range
can reach up to 7 m diameter with a 360° detection angle
(See FIG.2).
Sensor unit: 111.5 x 70 mm (See FIG.1-C)
FIG.1-C
FIG. 2
INSTALLATION AND WIRING
3
3.1 Proper Location
Side view Top view
6
EKO07042 Occupancy Sensor
en

FIG.3
3.1. 2Pay attentionto the walkingdirectionduringthe test.
EKO07042 is more sensitive to movement
across the sensor and less sensitive to movement
directly towards to sensor which will reduce the
detection coverage (See FIG.3).
3.1.3 Helpful tips for installation
Since the sensor is responding to temperature change, please
avoid the following conditions (See FIG.4-A & FIG.4-B).
The sensor aiming toward the objects which may be swayed
in the wind, such as curtain, tall plants, miniature garden, etc.
More sensitive to movement
across the pattern Less sensitive to movement
directly towards sensor
The sensor aiming toward the objects whose surface are
highly reflective, such as mirror, monitor, etc.
Mounting the sensor near heat sources, such as heating
vents, air conditioning, vents as dryers, lights, etc.
FIG.4-A
7
EKO07042 Occupancy Sensor
en
en

3.2 Wiring
3.2.1 Push button function
The load can be manually switched on by using an external
push button switch (N.C. 10 A type,See FIG.5 - FIG.6).
When the load is off, it can be switched on by a short press
(1sec) on push button switch and Lux is disabled. After
the load is switched on manually, the load can be auto-
matically switched off if no movement is detected and the
delay time has expired.
8
EKO07042 Occupancy Sensor
FIG.4-B
en

FIG.5
FIG.6
Load
Load
L
N
N
L
Push button
(N.C. Type)
Push button
(N.C. Type) Push button
(N.C. Type)
Power box
Power box Power box
3.2.2 EKO07042 for standard application (See FIG.5).
3.2.3 One load is controlled by two sensors to enlarge
detection area (See FIG.6).
3.2.4 Staircase timer switch control (Timer should be set to
, See FIG.7).
9
EKO07042 Occupancy Sensor
en

3.3.1 Flush mount
FIG.7
FIG.8
3.3 Installation Procedure
Load
Staircase timer switch
Drill a hole with
=65 mm on the
ceiling
OUT IN
N
L
N
L
Push button
(N.C. Type) Push button
(N.C. Type)
Power box
NOTE
When sensor is flush mounted with spring clip, protection
cap of terminals must be used.
To install sensor, please drill a hole with diameter of 65 mm
on ceiling board and keep the power cable outside. Please
strip off 6 - 8 mm of cable sheathing for wiring (See FIG.8).
10
EKO07042 Occupancy Sensor
en
Table of contents
Languages:
Other elco Accessories manuals