Ecolab SCLS IV User manual

TABLE OFCONTENTS
1.1
SystemIntroduction.......................................................1-1
1.2
Preface .......................................................................................................
1-1
1.3
SystemFeatures ........................................................................................1-1
2.1
Requirements/Specifications.....................................2-1
2.2
Utility Requirements....................................................................... 2-1
2.2.1
Electrical Supply Requirements… ....................................................2-1
2.2.2
WaterSupply Requirements .................................................. 2-1
2.2.3
Electrical
..........................................................................................
2-1
2.3
Specifications .............................................................................2-2
2.3.1
Dimensions
...................................................................................................
2-2
3.1
System Installation.....................................................3-1
3.2
Installation Procedure..................................................................... 3-1
3.1.1 Mounting the SCLS IV to the SCLS .............................................3-1
3.3
Wiring (wiring diagram belowFigure 3-2).......................................... 3-2
3.4
Plumbing........................................................................................ 3-3
4.0 System Programming ................................................4-1
5.0 Startup and Operation ...............................................5-1
6.1
Troubleshooting.........................................................6-1
6.2
Product not dispensing ........................................................................6-1
7.0 Replacement Parts....................................................7-1

1.1
System Introduction
1.2
Preface
This manual presents the basic installation, operation, programming and servicing instructions for the SCLS
IV/AQUANOMIC EU IV DISPENSING MODULE. This manual applies, in its entirety, to current equipment.
Guidelines are suggested in reference to the preferred method of installation, however, the surrounding
physicalenvironmentdictatetheactualinstallationoftheSCLSIV/AQUANOMIC EUIV DISPENSING MODULE.
This system will convert the standard three product dispenser to a four product dispenser.
WARNING: These installation, operation and servicing instructions are for use by qualified personnel
only. The installation must be made in accordance with local plumbing and electrical codes.
1.3
SystemFeatures
The SCLS IV/AQUANOMIC EU IV DISPENSING MODULE unit offers the following features:
•Addition of a fourth product will give improved application flexibility.
•
Accurate dispensing of the fourth solid product through the SCLS/
AQUANOMICEUdispenser.
•Thefourthsolidproducthastheemptycapsulealarm.
•Thefourthproduct willbedischarged through thecurrentpump andconductivitycell.
•Twotypesofproductcapsuleswillbeprovidedtopreventemployeesfromswapping
pocketswhen twounitsand twotypesofproductareat the samelocation.
SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual
1-1

Pre & Post
Flush
Nozzle
SCLSIV/AQUANOMIC
EUIV
Dispensing Module
Product Nozzle
Vacuum
Breaker
Detergent
Nozzle
Pre & Post
Flush Nozzle
Bleach
Nozzle
Sour/
Softene
r Nozzle
Sump
Detergent
Solenoid
Valve
Sump
Bleach
Solenoid
Valve
Pressure
Gauge
N.O.
N.C
Softene
r
Control
Valve
Main
Solenoid
Valve
Pump Inlet Hose
Regulator
Water Strainer
Inlet Assembly
Pump
Discharge
Manifold
Thermistor
Conductivity Cell
Electrodes
Laundry Machine #2
Solenoid
Laundry Machine #1
Solenoid
Hydraulic Diagram
Check Valves
Figure 1-1

1-2 SCLS IV/AQUANOMICEU IV Dispensing Module Installation & Operation Manual

2.1
Requirements/Specifications
2.2
Utility Requirements
2.2.1
ElectricalSupplyRequirements
•
A constant 120 VAC/60Hz. power source is required.
•
The pump Cabinet is shipped with a 9’ power cord.
•Fordistancegreaterthan9’, the PumpCabinetmustbehardwiredwithconduit.
•
The double pole single throw ON/OFF switch is also a circuit breaker rated at 3.0 amps.
•
Totalamperage draw during normal operation is approximately 2.5 amps.
2.2.2
WaterSupplyRequirements
•A3/8” MNHThotwatersupplylineisrequired.TheNSFhoseisshippedintheInstallationKit.
•Watertemperatureshould not fallbelow95°F (35°C).
•
Water flow rate is 0.8 GPM.
2.2.3
Electrical
The SCLS IV/AQUANOMICEU IV does not require any additional electrical or water service relative to the main
dispenser. The SCLS IV/AQUANOMICEU IV runs on 24 volt electrical service originating from the main
dispenser cabinet. The SCLS IV/AQUANOMICEU IV uses water from the main dispenser and therefore does
not require additional water hook up.
SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual 2-1

2.2
Specifications
The following section discusses the cabinet space and service access requirements:
2.2.1
Dimensions
The dispenser module assembly has the following dimensions.
• Height....................20 1/4” (including standpipe 22”)
• Width ....................10 1/4”
• Depth .....................11”
•
Weight...................15lbs.(withproductupto21lbs.)
•Productclearanceneedstobe8” abovethecabinettoreplaceproductcapsules.
2-2 SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual
W
Figure 2-1

3.1
SystemInstallation
3.2
Installation Procedure
1.
Remove the protective label from the SCLS/AQUANOMIC EU cabinet’s left hand side. The label needs to be
removed in order to run the electrical and hydraulic service between the dispensers.
2.
If the SCLS/AQUANOMICEU has already been installed remove the cabinet from the wall per the
following instructions.
a.
Unplug the cabinet.
b.
Disconnect the communications cables.
c.
Turn off the watersupply.
d.
Disconnecttheproductdeliverytubing.
e.
Removetheoverflowhose.
f.
Remove the solid products.
g.
Remove Cabinet from the wall.
3.1.1 Mounting the dispenser.
1.
Install the mounting brackets according to Figure 3-1 below.
SCLS IV/AQUANOMICEU IVModule Bracket SCLS/AQUANOMIC EU Bracket
2.
Hang cabinets on the brackets with the SCLS IV/AQUANOMICEU IV to the left of the
SCLS/AQUANOMIC EU cabinet.
Figure 3-1
NOTE: Remove the protective label from the left side of the SCLS/Aquanomic EU cabinet prior to
hanging the cabinets.

SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual 3-1

3.2
Wiring (wiring diagram below Figure 3-2)
1.
Unwindthewhite/orange–orangeandwhite/red–redwirepairsintheSCLS/AQUANOMICEUcabinetand
feed through the tophole inthe left side ofthecabinet.
2.
Crimp a female quick disconnect to each of the four wires.
3.
Connect the orange wire to the male quick disconnect of the reed switch assembly (white wires).
4.
Connect the white/orange wire to the open 1/4” tab of the 4th product valve.
5.
Connect the red andthewhite/redwires to the open tabson the flushvalve.
SCLS IV/AQUANOMICEUIV cabinet SCLS/AQUANOMIC EUcabinet
Figure 3-2
3-2 SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual
SAFETY
WHT WHT
FLUSH
VALVE
4TH PRODUCT
VA LV E
12–PIN CONNECTOR TO J7, ON CPUBOARD
ORG WHT/ORG
RED
RED
ORG
This manual suits for next models
1
Table of contents
Other Ecolab Dispenser manuals
Popular Dispenser manuals by other brands

Silver King
Silver King Majestic SK12MAJ Technical manual and replacement parts list

Franke
Franke F3Dn Twin Service manual

STIEBEL ELTRON
STIEBEL ELTRON UltraHot Plus Operation and installation instructions

DAN DRYER
DAN DRYER 282 installation guide

Essity
Essity Tork 473208 manual

CBS
CBS SD300BU-88 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST