ecactus WH-SPHA3.6H-5.12kWh User manual

WH-SPHA3.6H-5.12kWh WH-SPHA3.6H-10.24kWh
WH-SPHA5.0H-5.12kWh WH-SPHA5.0H-10.24kWh
WH-SPHA6.0H-5.12kWh WH-SPHA6.0H-10.24kWh
USER MANUAL

2
CONTENTS
1.GENERAL INTRODUCTION .................................................... 5
1.1 System Introduction ..................................................................................... 5
1.2 Safety Introduction....................................................................................... 5
1.2.1 Protection of Warning Sign.................................................................. 5
1.3 Packing List ..................................................................................................... 7
1.4 System Appearance ...................................................................................... 9
1.5 Liability Limitation.......................................................................................12
2.INSTALLATION........................................................................ 12
2.1 Installation Site and Environment................................. 12
2.1.1 General...........................................................................................................12
2.1.2 Restricted Locations ...................................................................................13
2.1.3 Barrier to Habitable Rooms ......................................................................13
2.1.4 SELECT MOUNTING LOCATION..............................................................15
2.2 Installation Steps............................................................... 16
2.2.1Battery Box Installation...............................................................................16
2.2.2 Inverter Box Installation ............................................................................21
2.3 Cable Connection.............................................................. 23
2.3.1General ............................................................................................................23
2.3.2 Connect the Inverter Box and Battery Box ...........................................23
2.3.3 System Wiring ..............................................................................................30
2.3.4 Power Meter(AS4777.2:2020 CL7.3.4)..............................................32
2.3.5 External isolation devices for PV array(AS4777.2:2020 CL7.3.4)32
3.SYSTEM OPERATION............................................................. 33
3.1 Switch On ............................................................................ 33

3
3.2 Switch Off............................................................................ 35
3.3 Emergency Situations....................................................... 35
3.3.1 Emergency Procedure ................................................................................35
3.3.2 First Aid Measures.......................................................................................35
3.3.3 Firefighting Measures ................................................................................36
4. ECACTUS CONFIGURATION & WIFI RELOAD................ 37
4.1 Preparation ......................................................................... 37
4.2 Wi-Fi Reset & Reload....................................................... 38
4.3 Install Side Plate ................................................................ 39
5.EMS CONFIGURATIONS....................................................... 40
6. Wifo Monitor CONFIGURATION....................................... 41
7. Cleaning and Maintenance ................................................ 45
7.1 Cleaning............................................................................... 46
7.2 Storage and Maintenance............................................... 46
8.ANNEX ...................................................................................... 47
8.1 Datasheet(AS4777.2: CL 7.3.1,CL 7.3.2, CL7.3.3, CL,7.3.6) ....................47
9.LABELS ...................................................................................... 50
9.1 Inverter label....................................................................................................50
9.2 Battery label.....................................................................................................51

4
Copyright Statement
This manual is under the copyright of JIANGSU WEIHENG INTELLIGENT TECHNOLOGY
CO., LTD.(hereinafter referred to as WIFO PRO), with all rights reserved. Please keep the
manual properly and operate in strict accordance with all safety and operating
instructions in this manual. Please do not operate the system before reading through the
manual.
Version Information
Version
Date
Content
V1.0
2021-8-12

5
1.GENERAL INTRODUCTION
1.1 System Introduction
WH-SPHA series hybrid all-in-one battery energy storage system (BESS) is
designed for both indoor and outdoor use. BESS can store the DC power generated
by the PV array into the battery, or convert it into AC power to loads. This user manual
applies to the following products :WH-SPHA3.6H-5.12kWh/WH-SPHA3.6H-
10.24kWh/WH-SPHA5.0H-5.12kWh/WH-SPHA5.0H-10.24kWh/WH-SPHA6.0H-
5.12kWh/WH-SPHA6.0H-10.24kWh.
1.2 Safety Introduction
1.2.1 Protection of Warning Sign
●SYMBOLS EXPLANATION

6
●SAFETY WARNING(AS4777.2:2020 CL7.3.1, CL 7.3.3, CL7.3.5)
Any installation and operation on BESS must be performed by qualified electricians,
in compliance with standards, wiring rules or requirements of local grid authorities
or companies (like AS 4777 and AS/ NZS 3000 in Australia).
Before any wiring connection or electrical operation on BESS, all battery and AC
power must be disconnected from BESS for at least 5 minutes to make sure BESS is
totally isolated to avoid electric shock.
The temperature of BESS surface might exceed 60℃during working, so please make sure
it is cooled down before touching it, and make sure the BESS is untouchable for children.
Usage and operation of the BESS must follow instructions in this user manual,
otherwise the protection design might be useless and warranty for the BESS will be
invalid.
Do not open BESS cover or change any component without WIFO PRO ’s
authorization, otherwise the warranty commitment for the BESS will be invalid.
Appropriate methods must be adopted to protect BESS from static damage. Any
damage caused by static is not warranted by WIFO PRO.
The neutral continuity is maintained already internally when changing from on-grid to
standalone mode, no need external wiring.
This BESS includes an integrated residual current device (RCD).
If an external residual current device (RCD) is used, a device of type A should be used, with
a tripping current of 30 mA or higher.
This BESS uses active anti-islanding protection, the method is shifting the frequency of the
inverter away from nominal conditions in the absence of a reference frequency (frequency
shift).
This BESS is a multiple mode inverter, it is used for outdoor unconditioned without solar
effects. The maximum operating ambient temperature is 55 ℃.

7
1.3 Packing List
WH-SPHA-3.6H/5.0H/6.0H-5.12kWh
1xWifi
module
Terminal
accessory
Document
accessory
2 x upper and lower
connection plate
1x Meter
1xQuick Installation
Manual
Label accessory
4xM4*10
1xM4*10(PE)
1x Back
plate
4xCushions
10xCable ties
2xφ10*60
Disassemble
tool
1 x Left side plate
1 x Right side plate
Battery box side plate*1
1 x Left side plate
1 x Right side plate

8
WH-SPHA-3.6H/5.0H/6.0H-10.24kWh
1xWifi
module
2xcables
Terminal
accessory
Document
accessory
4x upper and lower
connection board
1x Meter
1xQuick Installation
Label
accessory
8xM4*10
1xM4*10(PE)
2x Back plate
4xCushions
15xCable
ties
4xφ10*60
Disassemble
tool
1 x Left side plate
1 x Right side plate
Battery box side plate*2
1x Left side plate
1 x Right side plate

9
1.4 System Appearance
LED INDICATORS:
STATUS
LED INDICATORS
Waiting
Blue LED blinking, with an interval of 1sec
Checking
Blue LED blinking, with an interval of 0.5sec
Normal
Blue LED on
DSP fault
Red LED on
Battery com. fault
Red LED blinking, with an interval of 1sec
Meter com. fault
Red LED blinking, with an interval of 0.5sec
Energy
indicators

10
Terminals of BESS:
A
B
C
D
E
F
G
Other manuals for WH-SPHA3.6H-5.12kWh