Dolphin DB 400 Product manual

DB, L, XL 400, 25, 50, 75
DOLPHIN PANEL MOUNTED
INFRARED TAP
INSTALLATION AND MAINTENANCE GUIDE
January 2020
www.divapor.com

2 | Dolphin Blue | DB, L, XL 400, 25, 50, 75 Series
3 Technical Data
4 Pack Contents
5 Pre-Installation Information
7 - 9 Tap Installation
10 - 12 Settings Adjustment
13 Battery Replacement Instructions
14 Maintenance
Filters Cleaning Instructions
Care and Cleaning of Chrome and Special Finishes
15 Spare Parts
16 Limited Warranty
17 Troubleshooting
CONTENTS
www.divapor.com

DB, L, XL 400, 25, 50, 75 Series | Dolphin Blue | 3
TECHNICAL DATA
Wall mounted electronic tap for cold or premixed water
Power Supply
Battery 6x1.5AA battery (DB/L/XL 400 models)
Transformer 9v transformer (DB/L/XL 425 + DB 475 models)
Recommended 0.5-8.0 bar (7-116 PSI)
Water Pressure With water pressure of more than 8 bars use a
pressure reducing valve
Sensor range Self adjusting sensor. Adjustable with remote control
Minimum sensor range 80mm
Maximum sensor range 300mm
Security time 90 seconds Can be changed with the DB51 remote control
Hot water temperature Max 70ºC
www.divapor.com

4 | Dolphin Blue | DB, L, XL 400, 25, 50, 75 Series
PACK CONTENTS
1 x Spout and attachments
(incl. electronic unit)
1 x wall rosette
1 x tubular base
1 x M4 6mm screw
1 x Allen key
1 x filter
DB/L/XL 400
IP67 battery
box
DB/X/XL 425
Transformer
DB, L, XL 400, 25, 50, 75
www.divapor.com

DB, L, XL 400, 25, 50, 75 Series | Dolphin Blue | 5
PRE INSTALLATION INFORMATION
CHECK CONTENTS
› Separate all parts from the packaging and check you have each part according to the
pack contents section, pages 4-6. Pay attention to the variations of the different
models.
› Make sure all parts are accounted for before discarding any packaging material.
› If any parts are missing, do not attempt to install your electronic tap.
Please call 0800 0723 404 immediately to notify us.
WARNING
› To avoid reflection problems keep a distance of
more than 300 mm. between the sink and the
spout.
› This tap model, with an infrared sensor pointing
down, is not intended to be used together with
a sink of a reflective material such as stainless
steel.
› If a sink strainer is straight below the tap sensor,
use a strainer with a non reflective finish (do
not use a chrome plated one).
PREPARATION FOR INSTALLATION
› Flush water supply lines thoroughly before installing the tap.
› Do not allow dirt,Teflon tape or metal particles to enter the tap.
› Shut off water supply.
Important All plumbing is to be installed in accordance with applicable codes and
regulations.
www.divapor.com

6 | Dolphin Blue | DB, L, XL 400, 25, 50, 75 Series
PRE INSTALLATION INFORMATION
WARNING
› Highly reflective surfaces directly beneath the sensor of this product, in particular
polished finish basin wastes/ strainers, will cause false activation of the infrared sensors
and can result in malfunction. We recommend satin or matt finish products which
can be found on our website.
› It is very important to allow permanent access to the mounting tail/nut of this
product for future servicing and repair. Where this is not possible see our wall plate
mounted products.
› To avoid reflection problems it is recommended to keep a distance of more than
300mm between the sink and the spout. If the distance is below 300mm a simple
mock-up should be effected to confirm the tap functions as desired in your application
before final installation.You may require a Dolphin Blue remote control to adjust the
range.
› Do not connect water or power supplies or remove the black label covering the nfra-
red sensor until you have read and understood these instructions. Please see page 13.
› It is not recommended to use DB400 series with a polished stainless steel sink. For
this type of application a separate panel-mounted sensor should be used – please
speak to our technical sales team.
› Please observe the guide to minimum cavity depths as shown in the table. This is
important because the water supply hose must not be kinked due to lack of space.
Please note we have provided this information as a guide and cannot be held
responsible for fundamental design
errors. If your situation differs to those
shown below please call us on 0800
0723 404, and we will provide you
with a solution.
Panel Minimum
thickness (A) void (B)
10-15mm 90mm
16-25mm 80mm
26-35mm 70mm
www.divapor.com

DB, L, XL 400, 25, 50, 75 Series | Dolphin Blue | 7
TAP INSTALLATION
INSTALLATION INSTRUCTIONS FOR DB/L/XL 400 + DB/L/XL 425
STEP 1 – INSTALLING THE TAP
1. Shut off the water supply
2. Drill a hole (23 to 24 mm) at the place where you want to install the spout of the
tap.
3. If your model includes an optional anti-rotation pin, drill a small hole just above the
previous one for the anti-rotation pin.
4. Insert the tap and its attachments through the wall.The aerator at the tap spout
must face the washbasin.
5. Insert the anti-rotation pin into the small hole (if needed)
6. Fix the base behind the wall with the hexagonal nut and the disk.
www.divapor.com

8 | Dolphin Blue | DB, L, XL 400, 25, 50, 75 Series
TAP INSTALLATION
STEP 2 – CONNECTING THE WATER SUPPLY
1. Fit the flexible pipe coming from the Tap base
to the solenoid valve housing.
2. Fit the water supply inlet to the adapter at the
solenoid valve housing. Inlet and outlet should
follow the indicating arrow at the solenoid
housing.
Note: Make sure the filter is located at the
solenoid inlet.
3. Connect the cable coming from the electronic unit to the solenoid valve.
Important: Tap was supplied with a Self Adjusting Sensor.The ideal sensor range for
the specific location will be set automatically.
Before proceeding to step 3 check that
no objects are in front of the sensor
besides the washbasin.
Now, remove the protecting
sticker that covers the sensor.
www.divapor.com

DB, L, XL 400, 25, 50, 75 Series | Dolphin Blue | 9
TAP INSTALLATION
STEP 3 – CONNECTING THE POWER SOURCE
1a. For DB/L/XL 400: Connect the other cable
coming from the electronic unit at the Tap
base to the battery box.
1b. For DB/L/XL 425: Connect the other cable
coming from the electronic unit at the Tap
base to the transformer. Plug the
transformer into the electricity socket.
2. After you have connected the power
source (Battery or Transformer) wait 15
seconds in order to allow the system to set
the ideal sensor range.
As an indication that the self adjusting is taking place, a red light in the sensor eye will
flash continuously.The solenoid valve will be opened and closed for 1 second as an
indication that the ideal sensor range was set and the product is ready for use.
3. Turn on the central water supply. Check for leaks.
Note: This tap includes a special aerator that allows you to adjust the water stream
direction on site in order to prevent water splashing if needed.To change the angle
of the water stream, simply move the adjustable tilting
plate by pressing it smoothly.
4. If the automatically adjusted sensor range is not
satisfactory, please refer to the section entitled “Settings
adjustment”.
www.divapor.com

10 | Dolphin Blue | DB, L, XL 400, 25, 50, 75 Series
SETTING ADJUSTMENT
ADJUSTING THE SENSOR WITH THE REMOTE CONTROL
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control, hold
the remote control straight in front of the sensor in a distance of about 6-8” (15-20cm).
Choose the function you want to adjust by pressing once on one of the function
buttons. After pressing once on a specific function button, a quick flashing of the LED at
the front of the sensor will occur. At this stage, you can change the setting by pressing
the (+) or the (-) buttons, every push will increase or decrease one level. After finishing
the adjustment, turn the water supply back on.
DETECTION
RANGE
DELAY IN
TIME
SECURITY
TIME
LOCK OUT
TIME
DELAY OUT TIME
TEMPORARY OFF
FUNCTION
SELF ADJUSTMENT
MODE
RESET
HYGIENE
FLUSH
www.divapor.com
This manual suits for next models
14