Dialight FL VIGILANT SERIES User manual

Document # 9100127242999 Rev.D / 33356
February 2016
FLOODLIGHT - “FL” VIGILANT SERIES
INSTALLATION INSTRUCTIONS
__________________________________________________________________________________________________________________________________________________________________________________________________
Page 1 of 4
1501 Route 34 South, Farmingdale, NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 www.dialight.com
Dialight de México S.R.L de C.V. Calle Lirios s/n Col. Carlos Pacheco, Ensenada Baja California, México C.P. 22830 +52 (646) 156-70-80
IMPORTANT: Please read carefully before installation and retain for future reference
To prevent possible shock hazard, the fixture should be installed by a qualified licensed electrician
All electrical connections must be in accordance with local codes, ordinances and National Electrical Code
The use of safety protection such as safety eye glasses and protective gloves are recommended
Proper grounding of the light fixture is essential for protection from shock, correct operation and the elimination of
electrical interference
WARNING: DO NOT ACCESS JUNCTION AREA WHEN ENERGIZED
DO NOT mount near gas or electric heaters
Light fixture should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized
personnel
DO NOT use this light fixture for other than intended use
Technical data indicated on the light fixture are to be observed
Changes or modifications to the light fixture are not permitted
Repairs must only be carried out by a qualified electrician
Only genuine Dialight replacement parts must be used when unforeseen repairs are required
DO NOT keep these operating instructions inside the light fixture
Wait 10 minutes before opening after de-energizing the light fixture
SAVE THESE INSTRUCTIONS!!
DANGER: RISK OF ELECTRICAL SHOCK. T RN OFF MAIN POWER SO RCE BEFORE SERVICE
Always transport and store the equipment in its original packaging and keep in a dry location
When unpacking check for any cracks or damage to casting and glass lens, if in doubt do not install!
Contact your local Dialight sales representative or visit us at www dialight com for contact information

Document # 9100127242999 Rev.D / 33356
February 2016
FLOODLIGHT - “FL” VIGILANT SERIES
INSTALLATION INSTRUCTIONS
__________________________________________________________________________________________________________________________________________________________________________________________________
Page 2 of 4
1501 Route 34 South, Farmingdale, NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 www.dialight.com
Dialight de México S.R.L de C.V. Calle Lirios s/n Col. Carlos Pacheco, Ensenada Baja California, México C.P. 22830 +52 (646) 156-70-80
IMPORTANT: Make sure application surface can handle weight of light fixture
* Dialight is not responsible for damage to application surface or fixture, if mounted onto a surface that can not handle weight of fixture
MOUNTING BRACKET INSTALLATION STEPS:
1 Place [2] mounting pads on either end of the mounting bracket
•Peel off adhesive backing from pad and adhere to mounting bracket as shown [Fig 1a]
2 Secure the mounting bracket onto application surface by means of hole pattern on mounting bracket [Fig 1b]
•Feed source wire through center oval opening of mounting bracket [Fig 1c]
Fig 1a Fig 1b Fig 1c
LIGHT FIXTURE INSTALLATION STEPS:
1 Place light fixture on installed mounting bracket [Fig 3]
2 Install center pivoting 5/16 hex bolt on both sides of light fixture [Fig 4] _ [do not tighten] _ repeat to other side
3 Aim light fixture to desired angle [Fig 5]
4 Once desired angle is established, install angle locking 1/4 x 3/4 long hex bolt [Fig 6] _ [do not tighten] _ repeat to other side
5 Torque all installed bolts as follows:
5/16 center pivoting bolts [Fig 4] …………………………………………… ……………………… suggested torque = 11 5 ft lb [15 6 Nm]
1/4 angle position bolts [Fig 6] …………… ………………………… ……………………………… suggested torque = 6 5 ft lb [8 8 Nm]
Fig 3 Fig 4 Fig 5 Fig 6

Document # 9100127242999 Rev.D / 33356
February 2016
FLOODLIGHT - “FL” VIGILANT SERIES
INSTALLATION INSTRUCTIONS
__________________________________________________________________________________________________________________________________________________________________________________________________
Page 3 of 4
1501 Route 34 South, Farmingdale, NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 www.dialight.com
Dialight de México S.R.L de C.V. Calle Lirios s/n Col. Carlos Pacheco, Ensenada Baja California, México C.P. 22830 +52 (646) 156-70-80
WIRING STEPS:
1 Loosen [do not re ove] the M6 socket bolts around the perimeter of the access cover
2 Remove the access from light fixture [Fig 7]
_ the access cover has a safety lanyard attached
WARNING: To retain seal integrity (and preserve warranty) do not loosen or remove any of the bolts around the lower
perimeter of the rear junction box of the light fixture Do not loosen or remove any of the bolts around the front glass lens of the
light fixture There are no serviceable components in the light fixture Removal or loosening of any of these bolts will void all
warranties
4 Install a cord grip to suit the gauge source wiring being used [Fig 8]
a. cord grip not supplied with light fixture *
b. install as per cord grip manufacturer recommendation
5 Feed source wire through installed cord grip into light fixture junction area [Fig 9]
6 Connect source wires to terminal block as described:
a strip SOURCE wires = 39”- 43” [10-11 mm] ___ 12-20 AWG [4 0-0 5 mm
2
]
b connect SOURCE GROUND wire to terminal block position marked with GROUND SYMBOL
c connect SOURCE NEUTRAL wire to terminal block position marked with “N”
d connect SOURCE LIVE wire to terminal block position marked with "L1"
_to connect source wires, press down on the tabs on top of the terminal block [with tool] and hold
_insert stripped source wire _ release tab _ the terminal should now have engaged the inserted wire
_lightly tug on the inserted wire to ensure engagement has occurred
7 Tighten cord grip as per manufacturer recommendation
8 Once source wires are secured and connected, restore proper power to light fixture and check for illumination
CAUTION: Do not look directly into module once powered and lit. Use protective shaded eye wear when viewing
9 Once tested and approved _ replace access cover [Fig 7] …………………………………………… suggested torque = 3 ft lb [0 13 Nm]
_ make sure o ring gasket seal is still attached to access cover to assure proper seal
Fig 7 Fig 8 Fig 9
* Dialight is not responsible for selection of cord grip used on the installed light fixture
Dialight only suggests that the cord grip selected to be used on the installed light fixture conforms to agency specifications required

Document # 9100127242999 Rev.D / 33356
February 2016
FLOODLIGHT - “FL” VIGILANT SERIES
INSTALLATION INSTRUCTIONS
__________________________________________________________________________________________________________________________________________________________________________________________________
Page 4 of 4
1501 Route 34 South, Farmingdale, NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 www.dialight.com
Dialight de México S.R.L de C.V. Calle Lirios s/n Col. Carlos Pacheco, Ensenada Baja California, México C.P. 22830 +52 (646) 156-70-80
Mechanical Information
Dimensions
Weight
Light Fixture w/ bracket = 35 lbs [ 15 9 kg ]
Table of contents
Other Dialight Floodlight manuals

Dialight
Dialight D1RW-C13-006 Manual

Dialight
Dialight FL series User manual

Dialight
Dialight ProSite Installation instructions

Dialight
Dialight ProSite Installation instructions

Dialight
Dialight ProSite Installation instructions

Dialight
Dialight ProSite Installation instructions

Dialight
Dialight FL SERIES User manual

Dialight
Dialight ProSite Floodlight UL 1598 Installation instructions

Dialight
Dialight ProSite Installation instructions