Detecto D401 User manual

DIGITAL
GLASS SCALE
MODEL #D401
USER MANUAL

Table of Contents
INTRODUCTION .................................................................................................................3
NOTES ON SAFETY ............................................................................................................3
PRECAUTION NOTICE .......................................................................................................4
PRODUCT DESCRIPTION ...................................................................................................4
FRONT VIEW .........................................................................................................4
LCD DISPLAY .........................................................................................................5
FEATURES & KEY ASSIGNMENTS..........................................................................5
ITEMS INCLUDED IN THE PACKAGE ...................................................................6
BACK VIEW ...........................................................................................................6
PREPARATION BEFORE USE .............................................................................................7
OPERATION ........................................................................................................................8
WEIGHING-MODE.................................................................................................8
MEMORY RECALL MODE .....................................................................................9
USER SETTING MODE.........................................................................................10
CLOCK MODE .....................................................................................................10
CLOCK EDIT MODE.............................................................................................11
UNIT CHANGE MODE .........................................................................................11
MESSAGE DISPLAY ..............................................................................................11
ADVISE FOR USE AND CARE ............................................................................................11

Congratulations! You have purchased a precision health monitoring
product that should provide you with years of accurate use. To assure
you obtain the best performance please read the following set-up and
use instructions carefully before using the scale.
INSTRUCTION MANUAL
Note: Read this Instruction Manual carefully and keep it handy for future reference
2. Tact Switch
This scale is set to pounds. You can set the "kg/cm, lb/in” unit of measure switch located on
the back of the scale for kilograms or pounds.
3
NOTES ON SAFETY
Please read this section carefully to familiarize yourself with features and operations
before using the unit.
• The warning signs and the sample icons shown here are listed in order for you to use
this product safely and correctly as well as to prevent product damage, risk and injury
to you and others.
• The icons and meanings are as follows:
PRECAUTION NOTICE
Indicates the right conditions to use the
product and to prevent damage, risk
and injury.
IMPORTANT NOTICE TO USERS Indicates important notices users should
read before using the product.
CARE AND MAINTENANCE
Indicates matters in which the possibility of
damage may happen as a result of incorrect
handling and improper maintenance.

PRECAUTION NOTICE
• This product is intended for adults and children (ages 10 to 85).
• Make sure use only the type of battery stated (see section “PREPARATION BEFORE USE”).
• Be sure there is a clear line of sight between the Infrared Transmitter (on the Scale)
and the Infrared Receiver (on the Remote Display Unit).
4
Infrared Transmitter
PRODUCT DESCRIPTION
FRONT VIEW
Infrared Receiver
LCD Display
SET
1. Male Icon
2. Female Icon
3. Wieght indication
4. Daily Calorie
2
9
3
1

FEATURES
1. 4 x 7-segment characters LCD display
2. Weight capacity: 182kg/400lb with 0.1kg/0.2lb graduation
3. Unit change between LB/KG/ST (EEPROM option: default LB).
4. 4 user memories to store user records
5. User input includes Gender, Age, Height
6. Information output includes Weight, and Daily Calorie Consumption
7. Battery low detection function
8. Clock and Temperature (0C~50C)/(32F-122F) function
KEY ASSIGNMENTS
Unless otherwise specified, below are the functions of the keys.
[UP] - to increment the numeric value
- to toggle the user selection
- to recall user memory
[DOWN] - to decrement the numeric value
- to toggle the user selection
- to recall user memory
[SET] - to change the unit(LB/KG/ST)
- to go to User Setting Mode
BACK VIEW
(Scale Unit) (Remote
Display
Unit)
5
Battery Compartment CR2032 Lithium Battery Compartment
2 pcs AAA Alkaline Battery Compartment
ITEMS INCLUDED IN THE PACKAGE
Scale unit
1 pc remote display unit
1 pc wall mounting bracket
4 pcs plastic wall plugs
4 pcs M3x25 screws

6
PREPARATION BEFORE USE
1. Insert the Battery
Open the battery cover on the back of the scale unit.Insert 3 pieces AAA
alkaline batteries (not included).
Open the battery cover on the back of the wireless remote display
unit. Insert 2 pieces AAA alkaline batteries separately in two battery
compartment (not included). Remove the red strip from CR2032
lithiumbattery compartment in first use or insert the battery after
replacement.
Be sure that the polarity of the batteries is set
properly for proper function. If you do not intend to use this unit
fora prolonged period of time, it is advisable to remove the
batteries before storage.
Open the battery door Scale
Open the battery door Remote Direction of 4 pcs
AAA batteries
3 pieces AAA
alkaline batteries
Direction of the
CR2032 battery
TIPS
1. Replace batteries
in the scale unit,
when Lo is
displayed.
2. Replace batteries
in the remote
display unit, when
bAtt is displayed.
3. Do not remove the
CR2032 lithium
battery and 3 pcs
AAA batteries at
the same time,
otherwise clock
and memory
must be reset
again.
1.5V AAA
1.5V AAA
+
-
-+
1.5V AAA
1.5V AAA
+
-
-+
IMPORTANT NOTICE TO USERS!
1. Choose the location to mount the display on the wall. The location should be
free of temperature extremes and water. It should be where the display can
be easily viewed and operated. Keep away from direct sunlight and where the
operator easily reaches the display.
2. Make sure the structure and mounting hardware is solid enough to support
the display. The mounting brackets should be securely fastened to the wall so
that it cannot loose from the mounting surface.

a. Drill two holes on the wall with the distance in between two holes is 58mm (Fig.1)
Make sure the height of the holes is between 140cm and 180cm from floor (Fig.2).
b. Insert two plastic wall plugs into the holes until they are flush with the wall. Place the
bracket against the wall and insert two M3x25 screws through the holes into the wall
plug. Use screwdriver to tighten the screws (Fig.1).
c. Hang the remote display unit in the bracket on the wall.
Use the scale on a flat and hard floor surface. And make sure the scale in front of the remote
with the distance from 15cm to 55cm (Fig.2).
Press lightly on the scale platform to start-up the scale, the display shows “0000” and will
cyclic show on screen. Then display returns to clock mode. The scale is ready for use.
7
Hole on the wall 58mm
140-180cm
15-55cm
Wall plug
M3 x 25 screw
Wall bracket
1. Fix the Wall Mounting Bracket
3. Set the Right Position
4. Start-up the Scale
(Fig. 2: First auto zero)
1. Having inserted the battery in remote device, the remote state is still in clock mode. After insert
the battery for base scale, tap on the base scale, it asks the remote displays “oooo” and then
step off the scale, it ask the remote to display running “o” to indicate that it is measuring the zero
weight (Fig.2).
OPERATION

2. The base scale measures the weight. After a
stable weight is obtained, it asks the remote
to display the weight value (Fig.5).
1. During the base scale is OFF, when the user step onto the base scale, it wakes up the remote
display to have animation as in Fig.4.
3. The scale starts measuring the zero weight if the user steps off the scale. Then, the scale turns off.
2. If the base scale detects battery low, it will ask the remote to display “ Lo ” on LCD (Fig 3a).
If the battery low is in remote control itself, it will show “bAtt”(Fig 3b).
3. If the user steps onto the scale, the scale turns on and goes to Weighing Mode directly unless
it is the first time after the battery insertion or no valid zero weight is stored before. The scale
measures the zero weight and then sleep.
8
(Fig. 4: Weight trigger)
(Fig. 5: Weight obtained and locked)
(Fig. 6:User select)
(Fig. 3a) (Fig. 3b)
1. During the remote is in Clock mode, press [UP] or [DOWN] key to go into this
Memory Recall Mode, the user number will be flashed (Fig.6)
Weighing Mode
Memory Recall Mode

9
(Fig. 7: User recall)
(Fig.8: weight
result display)
2. User press [UP] or [DOWN] to select the user memory and confirm the selection for idle
2 seconds operation. Then the user information will be shown (Fig.7)
3. User steps on the base scale and trigger the weight such as 4.2.
4. After the weight is stable and locked, the base scale transmits the value to the remote, the
remote displays among the weight, and the calorie for 2 times with each reading shown for
about 3 seconds (Fig.8).
5. If the user steps off the scale, the scale starts measuring the zero weight and asks the remote to
display running zero animation. (Fig.9).
(Fig.9: auto zero)
6. If the zero weight is different with previous zero value, the base scale tells the remote to display
“Err0” (Fig 10) and then go back to the clock mode.
(Fig.10: auto zero)

10
7. If the user does not step off the scale, the scale will go back to clock mode automatically.
(Fig.9: Clock and temperature
)
(Fig.13 12/24 with C/F toggle)
(Fig.11:User Setting)
1. During the remote is in Memory Recall Mode, press [UP]/[DOWN] keys to select user and press
[SET] key to go into this User Setting Mode in order to edit the user record.
2. User may set the height, age, and gender (Fig11.).
1. The clock and the temperature will be displayed toggle every 5 seconds as Fig.12
2. Press <CLOCK> to toggle the display of 12/24hour (optional) or Fahrenheit/Celsius(Fig.13).12
hours and Fahrenheit are default setting
1. Having entered all items, the data is stored into the EEPROM.
User Setting Mode
Clock Mode
Table of contents
Other Detecto Scale manuals

Detecto
Detecto 750 User manual

Detecto
Detecto 495 User manual

Detecto
Detecto 8440 User manual
Detecto
Detecto icon User manual

Detecto
Detecto 6745 User manual

Detecto
Detecto 6437 User manual

Detecto
Detecto D217 User manual

Detecto
Detecto 6550 User manual

Detecto
Detecto PS-4 User manual

Detecto
Detecto d219 User manual

Detecto
Detecto DR550C User manual

Detecto
Detecto D161 User manual

Detecto
Detecto 7550 User manual

Detecto
Detecto APEX-RI User manual

Detecto
Detecto D410 User manual

Detecto
Detecto 685 Series User manual

Detecto
Detecto VET550 User manual

Detecto
Detecto GP-400-758C User manual

Detecto
Detecto 6560 User manual

Detecto
Detecto 337 User manual





















