Delta PFS3106 User manual

I
4/8-Port 10/100 Mbps Unmanaged
Hardened PoE Switch with 1 Gigabit
RJ-45 Port and 1 Gigabit SFP
User's Manual
V1.0.1

II
Foreword
General
This user's manual (hereinafter referred to be "the manual") introduces the features and
structure of 4/8-Port 10/100 Mbps Unmanaged Hardened PoE Switch with 1 Gigabit RJ-45 Port
and 1 Gigabit SFP.
Safety Instructions
The following categorized signal words with defined meaning might appear in the manual.
Signal Words
Meaning
Indicates a high potential hazard which, if not avoided, will result in
death or serious injury.
Indicates a medium or low potential hazard which, if not avoided,
could result in slight or moderate injury.
Indicates a potential risk which, if not avoided, could result in
property damage, data loss, lower performance, or unpredictable
result.
Provides additional information as the emphasis and supplement to
the text.
Revision History
Version
Revision Content
Release Time
V1.0.1
Updated foreword
November 2020
V1.0.0
First release.
November 2020
About the Manual
●The manual is for reference only. If there is inconsistency between the manual and the
actual product, the actual product shall prevail.
●We are not liable for any loss caused by the operations that do not comply with the manual.
●The manual would be updated according to the latest laws and regulations of related
regions. For detailed information, see the paper manual, CD-ROM, QR code or our official
website. If there is inconsistency between paper manual and the electronic version, the
electronic version shall prevail.
●All the designs and software are subject to change without prior written notice. The product
updates might cause some differences between the actual product and the manual. Please
contact the customer service for the latest program and supplementary documentation.
●There still might be deviation in technical data, functions and operations description, or
errors in print. If there is any doubt or dispute, please refer to our final explanation.
●Upgrade the reader software or try other mainstream reader software if the manual (in PDF
format) cannot be opened.
●All trademarks, registered trademarks and the company names in the manual are the
properties of their respective owners.
●Please visit our website, contact the supplier or customer service if there is any problem
occurred when using the device.
●If there is any uncertainty or controversy, please refer to our final explanation.

III
Important Safeguards and Warnings
The manual helps you to use our product properly. To avoid danger and property damage, read
the manual carefully before using the product, and we highly recommend you to keep it well for
future reference.
Operating Requirements
●Do not expose the device directly to the sunlight, and keep it away from heat.
●Do not install the device in the damp environment, and avoid dust and soot.
●Make sure the device is in horizontal installation, and install the device on solid and flat
surface to avoid falling down.
●Avoid liquid spattering on the device. Do not place object full of liquid on the device to avoid
liquid flowing into the device.
●Install the device in the well-ventilated environment. Do not block the air vent of the device.
●Use the device at rated input and output voltage.
●Do not dissemble the device without professional instruction.
●Transport, use, and store the device in allowed ranges of humidity and temperature.
●Disconnect the power supply first to avoid personal injury when removing the cable.
●Voltage stabilizer and lightening arrester are optional according to site power supply and
surrounding environment.
Power Supply Requirements
●Use the battery properly to avoid fire, explosion, and other dangers.
●Replace the battery with battery of the same type.
●Use locally recommended power cord in the limit of rated specifications.
●Use the standard power adapter. We will assume no responsibility for any problems caused
by nonstandard power adapter.
●The power supply shall meet the SELV requirement. Use the power supply that conforms to
Limited Power Source, according to IEC60950-1. Refer to the device label.
●Adopt GND protection for I-type device.
●The coupler is the disconnecting apparatus. Keep it at the angle for easy to operate.
●Be sure to ground the device (connect with copper wire whose cross section is not less than
2.5 mm² and resistance to ground is less than or equal to 4Ω).
Battery Caution
●Do not ingest battery to avoid chemical burn hazard.
●This product contains a coin cell battery. If the coin cell battery is swallowed, it can cause
severe internal burns in just 2 hours and can lead to death.
●Keep new and used batteries away from children.
●If the battery compartment does not close securely, stop using the product and keep it away
from children.
●If you think batteries might have been swallowed or placed inside any part of the body, seek
immediate medical attention.
●Risk of explosion if the battery is replaced by an incorrect type.
●Do not throw or immerse into water, heat to more than 100℃(212℉)
, repair or disassemble,
leave in an extremely low air pressure environment or extremely high-temperature

IV
environment, crush, puncture, cut or incinerate.
●Dispose of the battery as required by local ordinances or regulations.

V
Table of Contents
Important Safeguards and Warnings.................................................................................................... III
1 Product Overview.................................................................................................................................. 1
1.1 Introduction ................................................................................................................................... 1
1.2 Features ......................................................................................................................................... 1
1.3 Typical Application....................................................................................................................... 1
2 Device Structure.................................................................................................................................... 3
2.1 4-Port Unmanaged Hardened PoE Switch ................................................................................. 3
2.1.1 Front Panel............................................................................................................................ 3
2.1.2 Upper Cover .......................................................................................................................... 4
2.1.3 PoE Power Supply................................................................................................................ 4
2.2 8-Port Unmanaged Hardened PoE Switch ................................................................................. 5
2.2.1 Front Panel............................................................................................................................ 5
2.2.2 Upper Cover .......................................................................................................................... 6
2.2.3 PoE Power Supply................................................................................................................ 6
3 Device Installation................................................................................................................................. 7
Appendix 1 Cybersecurity Recommendations ..................................................................................... 8

1
1 Product Overview
1.1 Introduction
4/8-Port 10/100 Mbps Unmanaged Hardened PoE Switch with 1 Gigabit RJ-45 Port and 1
Gigabit SFP is a type of layer two commercial switch. It provides 4 or 8 10/100 Mbps Ethernet
ports, 1 10/100/1000 Mbps self-adaptive RJ-45 port, and 1 1000 Mbps SFP fiber port.
1.2 Features
General Features
●Layer two hardened PoE switch.
●Supports IEEE802.3, IEEE802.3u, IEEE802.3ab/z and IEEE802.3X standards.
●MAC auto learning, aging, MAC address capacity 8K.
●Supports MDI/MDIX self-adaptation.
●RJ-45 port supports 10/100 Mbps self-adaptation, supports IEEE802.3af and IEEE803.3at
power supply standards.
●Adopts metal enclosure.
●Industrial wide working temperature design.
●Supports 48V DC–57V DC power supply and dual power backup.
Individual Features
●4-Port 10/100 Mbps Unmanaged Hardened PoE Switch: Port 1 supports Hi-PoE 60W power
supply.
●8-Port 10/100 Mbps Unmanaged Hardened PoE Switch: Port 1 and port 2 support BT 90W
power supply.
●Supports two transmission modes, including Extend Mode On and Extend Mode Off. Extend
Mode Off is a standard Ethernet mode with 100 Mbps transmission bandwidth, and supports
a maximum transmission distance of 100 m with six different types of cables. Extend Mode
On is a long-distance transmission mode with a transmission bandwidth of 10 Mbps, and
supports a maximum transmission distance of 250 m with six different types of cables.
1.3 Typical Application
The typical networking scene is shown as follows.

2
Figure 1-1 Typical networking scene of 4-Port Switch
Figure 1-2 Typical networking scene of 8-Port Switch

3
2 Device Structure
2.1 4-Port Unmanaged Hardened PoE Switch
2.1.1 Front Panel
Figure 2-1 Front panel
Table 2-1 The description of front panel
No.
Name
Description
1
10/100 Base-T
4 ×10/100 Mbps self-adaptive PoE power
supply ports.
2
10/100/1000 Base-T
10/100/1000 Mbps self-adaptive RJ-45 port.
3
100/1000 Base-X
100/1000 Mbps self-adaptive SFP fiber port.
4
Link/Act
Fiber port status indicator light.
5
PWR
Power indicator light, and it is also the PoE
power supply status indicator light.
6
Link indicator light
When linking up, the indicator light is solid
on.
7
Act indicator light
When the data passing the switch, the
indicator light flashes.
8
PoE indicator light
PoE power supply status indicator light.
9
Link/Act indicator light
Ethernet port status indicator light.

4
2.1.2 Upper Cover
Figure 2-2 Upper cover
Table 2-2 The description of upper cover
No.
Name
Description
1
Ground terminal
GND.
2
PWR2/PWR1
Power ports, dual power backup access.
Supports 48V DC–57V DC power input.
3
Extend Mode
●ON: Long-distance transmission mode with
10 Mbps transmission bandwidth, and
supports a maximum transmission distance
of 250 m with six different types of cables.
●OFF: Standard Ethernet mode with 100
Mbps transmission bandwidth, and supports
a maximum transmission distance of 100 m
with six different types of cables.
4
PD Alive
When PD Alive is dialed to ON, the switch
perceives that there is no flow output of the
camera and determines that the camera
crashes. The camera is restarted through PoE
power-off to solve the problem.
2.1.3 PoE Power Supply
●One 100 Mbps RJ-45 port supports IEEE802.3af, IEEE802.3at standards and Hi-PoE 60W
power supply.
●Three 100 Mbps RJ-45 ports support IEEE802.3af, IEEE802.3at standard power supply.

5
2.2 8-Port Unmanaged Hardened PoE Switch
2.2.1 Front Panel
Figure 2-3 Front panel
Table 2-3 The description of front panel
No.
Name
Description
1
10/100 Base-T
8 ×10/100 Mbps self-adaptive PoE power
supply ports.
2
10/100/1000 Base-T
10/100/1000 Mbps self-adaptive RJ-45
port.
3
1000 Base-X
1000 Mbps SFP fiber port.
4
Link/Act
Fiber port status indicator
5
PWR
Power indicator light, and it is also the PoE
power supply status indicator light.
6
Link indicator light
When linking up, the indicator light is solid
on.
7
Act indicator light
When the data passing the switch, the
indicator light flashes.
8
PoE indicator light
PoE power supply status indicator light.
9
Link/Act indicator light
Ethernet port status indicator.
This manual suits for next models
2
Table of contents
Other Delta Switch manuals

Delta
Delta AGC7648A User manual

Delta
Delta NovoConnect B360 User manual

Delta
Delta DVS Series User manual

Delta
Delta DVS Series User manual

Delta
Delta STS30002SR00035 User manual

Delta
Delta AG9032 User manual

Delta
Delta OR-CR-213 User manual

Delta
Delta MST-01 User manual

Delta
Delta LE-764501 User manual

Delta
Delta IPB-5-10A-S4 User manual

Delta
Delta AG9064 User manual

Delta
Delta EXPERT-POE-1616 User manual

Delta
Delta EXPERT-POE-54G User manual

Delta
Delta HYPERSPROUT User manual

Delta
Delta Agema Series User manual

Delta
Delta Agema AG5648 User manual

Delta
Delta AG7648 User manual

Delta
Delta DVS Series User manual

Delta
Delta AG6248C User manual

Delta
Delta AG9032 V1 User manual