DeLonghi SRI User manual

02
HR
SI
BG
RO
INFRARED GAS HEATER (EN)
PLINSKA INFRACRVENA GRIJALICA (HR)
PLINSKA PEČ Z NASTAVLJIVIM MODRIM PLAMENOM (SI)
ГАЗОВА ПЕЧКА С ИНФРАРЕД ТЕХНОЛОГИЯ (BG)
SOBĂ PE GAZ CU INFRAROŞU (RO)
SRI

INFRARED GAS HEATER
Technical Data
This appliance is designed to operate with BUTANE-PROPANE at nominal pressure: 30mbar. For
a correct gas combustion the required air quantity is 8,4 m3/h.
WARNINGS
- ALWAYS use heater in accordance with instructions. Read the instructions book carefully and
keep it in a safe place.
- This appliance requires a rubber tube and a pressure regulator in accordance with the law in
force. If not supplied check with your gas supplier.
- Use ONLY in a well ventilated area.
- The appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the applian-
ce.
- This appliance MUST NOT be used in basements, high rise flats, bathrooms or bedrooms and
in rooms having volume less than 15 m3(30 m3in living rooms).
- This appliance emits the combustion residues in the room in which is used.
- DO NOT place clothes or other materials on the heater, as apart from the danger of fire their
presence could affect the efficient working of the appliance (fig. 1).
- DO NOT move heater from room to room when it is lit (fig. 2).
- DO NOT position heater alongside a wall or near curtains or arm-chairs etc. (fig. 3 - 4).
- ALWAYS face heater towards centre of room. Special care should be taken if the heater is on
a surface where it can move or twist on its wheels or castors if knocked by a child or dog, etc.
- Minimum Clearance: 200 mm from sides,1500 mm from front.
- Be sure installation is complying to local standard.
- The heater you have purchased is fitted with safety devices which come on in the event of
malfunctioning while the appliance is in use. If the pilot light (placed opposite the burner)
accidentally goes out, or if the room is not sufficiently ventilated, the safety device will block
the gas flow, causing the heater to go off.
- DO NOT use in recreative vehicle (caravans and campers).
2
G30/G31 I3B/P
Gas
Type Category
Maximum
Input
Medium
Input
Low
Input Gas pressure
30mbar
4.20 305
KW g/h
2,85 207
KW g/h
1,50 109
KW g/h
Fig.1 Fig.2 Fig.3 Fig.4
EN

3
ASSEMBLY
GENERAL SAFETY INSTRUCTIONS
Gas bottle
Gas Bottle with 15 kg of maximum capacity can be installed. Changing of gas bottle must not be
carried out in the presence of a naked flame. Use the gas bottle always in upright position.MAKE
SURE the black neoprene “O -Ring Seal is in place or the regulator bullnose. Regularly examine,
and if unduly compressed or damaged, replace. Support regulator with one hand while aligning
the regulator bullnose (threaded part) with the threaded gas outlet on cylinder valve. Screw
regulator handwheel ANTICLOCKWISE (LEFT HAND THREAD) into gas outlet. Tighten regulator
handwheel as tight as possible by hand only. DO NOT USE TOOLS OR LEVERS TO TIGHTEN.To
place the bottle in position, remove the rear panel; than put the bottle in position and replace
the panel.
PLACE the cylinder in the heater cabinet so that the cylinder valve is facing into the compart-
ment. Take care to ensure that is positioned in such a way that the flexible hose does not come
into contact with the metal panels of the heater, and avoid twisting of the flexible hose. OPEN
cylinder valve by turning handwheel ANTICLOCKWISE. Now refer to the lighting instruction on
the heater itself. Please read carefully and follow the instructions. Do not turn the bottle upside
down to use completely its content.
Gas leakages
If a leak is suspected, turn off gas at the gas bottle, open the window and air the room. DO NOT
disconnect the pressure regulator. Extinguish all naked lights. Slowly turn the gas on and brush
the connections with soapy water or liquid detergent - a gas leak will form bubbles. If a leak is
found, turn the gas off and inform your Dealer. DO NOT use the heater again until it has been
inspected by your Dealer.
1) Place the gas cylinder in the gas cylinder
compartment and connect the regulator to
the cylinder.
2) To fit the back cover, align and place the
two locating screws on the left-hand side of
the back cover into the corresponding slots
in the cabinet. Then align and place the
screw on the right hand side into its slot.
IMPORTANT: to remove the back cover,
carefully lift the back cover and pull clear of
the slots.

4
NEVER USE MATCHES TO FIND LEAKS
Pressure regulators, hose and clips
CHECK that hose is completely over the nozzles at each end of the
tubing and that it is held firmly in place by tube clips (See figure).
Examine hose regularly and get your dealer to fit new hose 400mm
long if perished, worn or damage. The year of manufacture is printed
on the pipe. It is recommended to replace the pipe every 5 years. Use
only hose LPG according to standard BS3212/EN 1763.
When connecting the pressure regulator to the gas bottle avoid undue twisting of the hose. A
regulator seat at 28 ÷ 30 mbar (11.2 in w.g.) for Butane or Propane complying to local standard
must be connected to the appliance with the above hose, using suitable tube clips.
Ventilation
USE ONLY IN A WELL VENTILATED ROOM
Adequate ventilation must be provided in rooms in which the heater is used. This ensures remo-
val of the products of combustion and allows the entry of replacement air. The following table
shows the smallest size of room suitable for each heat setting and the dimensions of the apertu-
re which must be provided equally divided between high and low level, according with the
maximum, medium or minimum power.
Safety guard
The guard is to prevent risk of fire and no part of it should be permanently removed.
It does not give full protection for young children or the infirm.
OPERATING INSTRUCTIONS
Lighting the heater
1. Turn on the gas at the gas bottle tap.
2. FROM « G» POSITION, fully depress the control knob for 10 seconds and turn to (Small
Flame) position. (If pilot flame does not ignite return to starting position and repeat).
Continue to fully depress the knob for a further 20 seconds to allow the thermocouple probe
to heat up, then turn the knob to select the desired setting as follows:
(Small Flame) Low Input (Medium Flame) Medium Input,
(Big Flame) Maximum Input,
In the event of “burn back” turn off and try again. Should it happen a second time, return the
unit to the dealer.
Control knob setting Room Size Room Aperture
2) Position
big flame (maxi-
mum rate)
15 m3
105 cm2
3) Position
medium flame
(medium rate)
28.5 m3
1) Position small
flame
(low rate)
42 m3

5
Auxiliary ignition
Should piezoelectric starter fail to work, repeat operation on control knob and use a match to
light pilot flame.
Turning off the heater
Turn off the gas bottle tap.
The Heater will be totally “OFF” only if the tap at the gas bottle is turned off.
Important
When the operating knob is left at the end of the starting time (see rating plate), this must move
up about 5 mm and return to his starting height. If this does not happen, shut the gas valve and
contact your aftersales service centre. Do not let the item work with the operating knob pressed
downwards by force.
IMPORTANT
DO NOT cover the appliance when in operation, this could cause a dangerous risk of fire.
IMPORTANT NOTES
- Use the appliance only standing on the floor.
- The heater must always operate in upright position.
- Never direct the hater air flow towards furniture, curtains , spray cans and inflammable mate-
rial.
- Do not install the appliance in a room which might contain gas, oil or sulphur, or near sour-
ces of heat.
- After an extended period when the heater is not in use check the “O”-Ring Seal before ligh-
ting up the heater. Replace the “O” Ring Seal if cracked or broken.
- Do not use the appliance in the mountains at high altitudes.
- DIARISE: During March/April of each year check the “O” Ring Seal.
MAINTENANCE
Wipe your appliance with a soft damp cloth and only when it is switched off, cold and unplug-
ged. Do not use solvents or abrasives detergents.
Check that there is no dust blocking the air inlet or outlet grids. Clean using a vacuum cleaner.
When not in use remove plug from socket. When not in use the heater should be covered and
stored in a dust-free place. Refer any major maintenance to your Local Authorised Dealer. Major
servicing should be carried out every 2 - 3 years. If in doubt refer to your nearest authorised dea-
ler.
Table of contents
Other DeLonghi Gas Heater manuals
Popular Gas Heater manuals by other brands

Superior
Superior BGE18NV Installation and operation instructions

Dru
Dru Room-sealed atmospheric gas-fired heating... user manual

klover
klover TKR 35 user guide

Rothenberger Industrial
Rothenberger Industrial 035984 instruction manual

New Buck Corporation
New Buck Corporation 34 user manual

Hargrove
Hargrove Timberland Glow Operation and installation guide

Superior
Superior BGE18NR Operation instructions

Brant Radiant Heaters
Brant Radiant Heaters QTD Series User instruction

L.B. White
L.B. White Therma Grow HW220 Owner's manual and instructions

Sealey
Sealey LP35.V5 instructions

Italkero
Italkero Falo Evo User manual and assembly instructions

Desa
Desa 30LP owner's manual