DeLonghi SBF User manual

BLUE FLAME GAS HEA
BLUE FLAME GAS HEATER
TER
5723001200 17-12-2003 15:10 Pagina 1

2
BLUE FLAME GAS HEATER
Technical Data
Type Category Maximum Medium Low Gas pressure
Input Input Input
KW g/h KW g/h KW g/h
4.20 305 2,85 207 1,50 109 2,8 kpa
This appliance is designed to operate with LPG at nominal pressure: 2,8 kpa. For a correct
gas combustion the required air quantity is 8,4 m3/h.
WARNINGS
-ALWAYS use heater in accordance with instructions. Read the instructions book carefully
and keep it in a safe place.
-This appliance requires a rubber tube and a pressure regulator in accordance with the
law in force. If not supplied check with your gas supplier.
-Use ONLY in a well ventilated area.
-This appliance MUST NOT be used in basements, high rise flats, bathrooms or
bedrooms and in rooms having volume less than 15 m3(30 m3in living rooms).
-This appliance emits the combustion residues in the room in which is used.
-DO NOT place clothes or other materials on the heater, as apart from the danger of fire
their presence could affect the efficient working of the appliance (fig. 1).
-DO NOT move heater from room to room when it is lit (fig. 2).
-DO NOT position heater alongside a wall or near curtains or arm-chairs etc. (fig. 3 - 4).
-ALWAYS face heater towards centre of room. Special care should be taken if the heater is on
a surface where it can move or twist on its wheels or castors if knocked by a child or dog, etc.
-Minimum Clearance : 200 mm from sides,1500 mm from front.
-Be sure installation is complying to local standard.
-The heater you have purchased is fitted with safety devices which come on in the event
of malfunctioning while the appliance is in use. If the pilot light (placed opposite the
burner) accidentally goes out, or if the room is not sufficiently ventilated, the safety devi-
ce will block the gas flow, causing the heater to go off.
Gas leakages
If a leak is suspected, turn off gas at the gas bottle, open the window and air the room. DO
NOT disconnect the pressure regulator. Extinguish all naked lights. Slowly turn the gas on
and brush the connections with soapy water or liquid detergent - a gas leak will form bub-
bles. If a leak is found, turn the gas off and inform your Dealer. DO NOT use the heater
again until it has been inspected by your Dealer.
NEVER USE MATCHES TO FIND LEAKS.
see rating label
Fig.1 Fig.2 Fig.3 Fig.4
5723001200 17-12-2003 15:10 Pagina 2

3
1) Place the gas cylinder in the gas cylinder
compartment and connect the regulator to
the cylinder as shown on page 4.
2) To fit the backcover, insert the two tabs
located on the left-hand side of the back-
cover into the corresponding slots in the
cabinet. Then insert the tab on the right
hand side into its slot.
IMPORTANT: to remove the backcover,
lift the backcover and pull clear of the
slots.
ASSEMBLY
GENERAL SAFETY INSTRUCTIONS
Gas bottle
Gas Bottle with 9 kg of maximum capacity can be installed. Changing of gas bottle must not
be carried out in the presence of a naked flame. Use the gas bottle always in upright posi-
tion.MAKE SURE the black neoprene “O -Ring Seal is in place or the regulator bullnose.
Regularly examine, and if unduly compressed or damaged, replace. Support regulator with
one hand while aligning the regulator bullnose (threaded part) with the threaded gas outlet
on cylinder valve. Screw regulator handwheel ANTICLOCKWISE (LEFT HAND THREAD)
into gas outlet. Tighten regulator handwheel as ttight as possible by hand only. DO NOT
USE TOOLS OR LEVERS TO TIGHTEN. When connecting the regulator to the gas cylinder,
avoid undue twisting of the flexible hose. To place the bottle in position, remove the rear
panel; than put the bottle in position and replace the panel.
PLACE teh cylinder in the heater cabinet so that the cylinder valve is facing into the compartment.
Take care to ensure that is positioned in such a way that the flexible hose does not come
into contact with the metal panels of the heater, and avoid twisting of the flexible hose.
OPEN cylinder valve by turning handwheel ANTICLOCKWISE. Now refer to the lighting
instruction on the heater itself. Please read carefully and follow the instructions. Do not turn
the bottle upside down to use completely its content.
5723001200 17-12-2003 15:10 Pagina 3

4
Pressure regulators, rubber tubes and clips
CHECK that tubing is completely over the nozzles at each end of the
tubing and that it is held firmly in place by tube clips (See fig.9).
Check the expiry date and state of the rubber tube regularly. If it is
past its expiry date or has been damaged, replace it with one which
complies with the current regulations. Avoid bending or constricting
the rubber tube when the pressure regulator is connected to the gas
cylinder. This heater must be used with an approved Low Pressure
Regulator which complies with SAB S1237.
The regulator is required to reduce the pressure of the gas in the cylinder from about 700
kPa to about 2,8 kpa to operate the radiant - the heating panels).
Ventilation
USE ONLY IN A WELL VENTILATED ROOM
Adequate ventilation must be provided in rooms in which the heater is used. This ensures
removal of the products of combustion and allows the entry of replacement air. The fol-
lowing table shows the smallest size of room suitable for each heat setting and the dimen-
sions of the aperture which must be provided equally divided between high and low level,
according with the maximum, medium or minimum power.
Safety guard
The guard is to prevent risk of fire and no part of it should be permanently removed.
It does not give full protection for young children or the infirm.
fig. 9
Control knob setting Room Size Room Aperture
2) Position
big flame
(maximum rate)
15 m3
105 cm 2
3) Position
medium flame
(medium rate)
28.5 m3
1) Position
small flame
(low rate)
42 m3
5723001200 17-12-2003 15:10 Pagina 4

5
OPERATING INSTRUCTIONS
Lighting the heater
1. Turn on the gas at the gas bottle tap.
2. FROM « ● » POSITION, fully depress the control knob for 10 seconds and turn to
(Small Flame) position. (If pilot flame does not ignite return to starting position and
repeat). Continue to fully depress the knob for a further 20 seconds to allow the thermo-
couple probe to heat up, then turn the knob to select the desired setting as follows:
(Small Flame) Low Input (Medium Flame) Medium Input,
(Big Flame) Maximum Input,
In the event of “burn back” turn off and try again. Should it happen a second time, return
the unit to the dealer.
Auxiliary ignition
Should piezoelectric starter fail to work, repeat operation on control knob and use a match
to light pilot flame.
Turning off the heater
Turn off the gas bottle tap.
The Heater will be totally “OFF” only if the tap at the gas bottle is turned off.
Important
When the operating knob is left at the end of the starting time (see rating plate), this must
move up about 5 mm and return to his starting height. If this does not happen, shut the gas
valve and contact your aftersales service centre. Do not let the item work with the operating
knob pressed downwards by force.
IMPORTANT
DO NOT cover the appliance when in operation, this could cause a dangerous risk of fire.
IMPORTANT NOTES
-Use the appliance only standing on the floor.
- The heater must always operate in upright position.
- Never direct the hater air flow towards furniture, curtains , spray cans and inflammable
material.
- Do not install the appliance in a room which might contain gas, oil or sulphur, or near
sources of heat.
- After an extended period when the heater is not in use check the “O”-Ring Seal before
lighting up the heater. Replace the “O” Ring Seal if cracked or broken.
- Do not use the appliance in the mountains at high altitudes.
- DIARISE: During March/April of each year check the “O” Ring Seal.
MAINTENANCE
Wipe your appliance with a soft damp cloth and only when it is switched off, cold and
unplugged. Do not use solvents or abrasives detergents.
Check that there is no dust blocking the air inlet or outlet grids. Clean using a vacuum clea-
ner. When not in use remove plug from socket. When not in use the heater should be cove-
red and stored in a dust-free place. Refer any major maintenance to your Local Authorised
Dealer. Major servicing should be carried out every 2 - 3 years. If in doubt refer to your
nearest authorised dealer.
5723001200 17-12-2003 15:10 Pagina 5

5723001200/12.03
5723001200 17-12-2003 15:10 Pagina 6
Table of contents
Other DeLonghi Gas Heater manuals
Popular Gas Heater manuals by other brands

Superior
Superior BGE18NV Installation and operation instructions

Dru
Dru Room-sealed atmospheric gas-fired heating... user manual

klover
klover TKR 35 user guide

Rothenberger Industrial
Rothenberger Industrial 035984 instruction manual

New Buck Corporation
New Buck Corporation 34 user manual

Hargrove
Hargrove Timberland Glow Operation and installation guide

Superior
Superior BGE18NR Operation instructions

Brant Radiant Heaters
Brant Radiant Heaters QTD Series User instruction

L.B. White
L.B. White Therma Grow HW220 Owner's manual and instructions

Sealey
Sealey LP35.V5 instructions

Italkero
Italkero Falo Evo User manual and assembly instructions

Desa
Desa 30LP owner's manual