Datcon DT9102 I4 User manual

DT9102 I4
Intrinsically Safe Digital Clock
Operating Instructions

DT9102 I4
2 20220103-V0
Contents
1. About this document .....................................................4
1.1. Function ................................................................................... 4
1.2. Target group............................................................................. 4
1.3. Symbolism used....................................................................... 4
2. For your safety ...............................................................5
2.1. Authorised personnel ............................................................... 5
2.2. Appropriate use........................................................................ 5
2.3. Warning about misuse ............................................................. 5
2.4. General safety instructions....................................................... 5
2.5. CE conformity........................................................................... 5
2.6. Safety information for Ex areas................................................ 6
2.7. Environmental instructions ....................................................... 6
3. Product description .......................................................7
3.1. Delivery configuration............................................................... 7
3.2. Principle of operation ............................................................... 8
3.3. Adjustment ............................................................................... 9
3.4. Storage and transport .............................................................. 9
4. Mounting.......................................................................10
4.1. General instructions ............................................................... 10
4.2. Main dimensions of the instrument ........................................ 11
4.3. Mounting procedure ............................................................... 12
5. Connecting ...................................................................14
5.1. Preparing the connection ....................................................... 14
5.2. Connecting the digital outputs................................................ 15
5.3. Connecting into the current loop (synchronising input) .......... 16
6. Display and manual controls ......................................18
6.1. The first start-up ..................................................................... 18
6.2. Characters and mnemonics appearing on the display ........... 19
6.3. Manual controls...................................................................... 21

DT9102 I4
20220103-V0 3
7. Setting-up .....................................................................22
7.1. Typing the code (password) in ............................................... 22
7.2. The menu ............................................................................... 24
7.3. Time set (01. menu item) ....................................................... 25
7.4. Fast time set (02. menu item) ................................................ 26
7.5. User code (03. menu item)..................................................... 27
7.6. Synchronisation mode (04. menu item) ................................. 29
7.7. Synchronisation time (05. menu item).................................... 30
7.8. Synchronisation gate time (06. menu item)............................ 31
7.9. Digital output 1 (07. menu item) ............................................. 32
7.10. Digital output 2 (08. menu item) ........................................... 33
7.11. Changing the supervisor code (09. menu item) ................... 34
7.12. Tests (10. menu item) .......................................................... 36
8. Fault rectification .........................................................38
8.1. Fault finding............................................................................ 38
8.2. Repairing................................................................................ 38
9. Dismounting .................................................................38
9.1. Dismounting procedure .......................................................... 38
9.2. Disposal ................................................................................. 38
10. Appendix.....................................................................39
10.1. Technical specifications ....................................................... 39
10.2. Application example ............................................................. 41
10.3. Error messages.................................................................... 42
10.4. Messages of critical errors ................................................... 43
10.5. Description of the menu items.............................................. 44
10.6. Messages and error messages during setting up ................ 47
10.7. Time set (example) .............................................................. 48
10.8. ATEX Certification................................................................ 50

DT9102 I4
4 20220103-V0
1. About this document
1.1. Function
This operating instructions manual has all the information
you need for quick set-up and safe operation of DT9102 I4.
Please read this manual before you start setup.
1.2. Target group
This operating instructions manual is directed to trained
personnel. The contents of this manual should be made
available to these personnel and put into practice by them.
1.3. Symbolism used
Information, tip, note
This symbol indicates helpful additional information.
Caution, warning, danger
This symbol informs you of a dangerous situation that could
occur. Ignoring this cautionary note can impair the person
and/or the instrument.
Ex applications
This symbol indicates special instructions for Ex
applications.
•
List
The dot set in front indicates a list with no implied sequence.
→
Action
This arrow indicates a single action.
1
Sequence
Numbers set in front indicate successive steps in a
procedure.

DT9102 I4
20220103-V0 5
2. For your safety
2.1. Authorised personnel
All operations described in this operating instructions
manual must be carried out only by trained and authorised
specialist personnel. For safety and warranty reasons, any
internal work on the instruments must be carried out only by
DATCON personnel.
2.2. Appropriate use
The DT9102 I4 is a 4–20mA loop-powered intrinsically safe
digital clock. Detailed information on the application range o
f
the DT9102 I4 is available in chapter „Product description”.
2.3. Warning about misuse
Inappropriate or incorrect use of the instrument can give rise
to application-specific hazards, or demage to system
components through incorrect mounting or adjustment.
2.4. General safety instructions
The DT9102 I4 is a high-tech instrument requiring the strict
observance of standard regulations and guidelines. The
user must take note of the safety instructions in this
operating instructions manual, the country-specific
installation standard as well as all prevailing safety
regulations and accident prevention rules.
2.5. CE conformity
The DT9102 I4 is in conformity with the provisions of the
following standards:
MSZ EN IEC 60079-0:2018 (ATEX)
MSZ EN 60079-11:2012 (ATEX)
MSZ EN IEC 61326-1:2021 (EMC)

DT9102 I4
6 20220103-V0
2.6. Safety information for Ex areas
Please note the Ex-specific safety information for installation
and operation in Ex areas. These safety instructions are
part of the operating instructions manual and come with the
Ex-approved instruments.
2.7. Environmental instructions
Protection of the environment is one of our most important
duties.
Please take note of the instructions written in the following
chapters:
•Chapter 3.4. Storage and transport
•Chapter 9.2. Disposal

DT9102 I4
20220103-V0 7
3. Product description
3.1. Delivery configuration
Delivered items The scope of delivery encompasses:
•DT9102 I4 digital clock
•2 pcs. of srew clamps (only panel mounting version)
• instrument sealing
•documentation:
this oparating instructions manual
certification
warranty
The instrument is built from the following main parts:
Main parts
1. instrument case
2. front panel with 3 mambrane push buttons

DT9102 I4
8 20220103-V0
3.2. Principle of operation
Area of application DT9102 I4 is an intrinsically safe digital clock enable
accurate time to be displayed in even the most hazardous
plant areas: Zone 1, 2 or in the safe area.
Synchronising function allows the clock to be synchronised
with a master clock. The clock can be synchronise through
the current loop. When the loop current is over 12 mA the
clock stop going when the loop current decrease under
8 mA the clock will re-start from a new time selected in the
programme menu. This may be the nearest minute or the
nearest hour of the original display or a preset time may be
entered during programming.
The DT9102 I4 has two isolated digital outputs, which can
be used for alarm signaling or for synchronising other
clocks.
DT9102 I4 is housed in a moulded polycarbonate case
hauseproof to IP65 for installation in the field or on the
control panel.
Operating principle
The clock incorporate a high accuracy temperature
compensated time base, which is processed by a
microcontroller. The microcontroller produces the real time,
in 24 hour HH:MM format, drives the large 4 digit 25,4 mm
height LCD display, process the front panel keypad, the
synchronising inputs, and drives the digital outputs. The
settings and the actual time are stored in a memory which
stores it’s content for cca. 1 hour for bridging the supply
current failure. The clock also going for cca. 1 hour at this
case.
Power supply DT9102 I4 is loop-powered from 4–20 mA synchronising
signal, dropping less than 2,2 V.
It is not recommended to bring the supply current below 8
mA.

DT9102 I4
20220103-V0 9
3.3. Adjustment
The DT9102 I4 can be adjusted through the 3 front panel
membrane keypad. The instrument doesn’t need any
internal adjustment.
All settings are stored in a battery back-up RAM.
At first installation you have to set the time and other
working parameters what you need.
At battery replacement the settings are kept for min. 1 hour.
3.4. Storage and transport
This instrument should be stored and transport in places
whose climatic conditions are in accordance with Chapter
10.1. Technical specifications, as described under the
title: Environmental conditions.
The packaging of DT9102 I4 consist of enviroment-friendly,
recyclable cardboard is used to protect the instrument
against the impacts of normal stresses occurring during
transportation. The corrugated cardboard box is made from
environment-friendly, recyclable paper. The inner protective
material is polyfoam and nylon, which should be disposed of
via specialised recycling companies.

DT9102 I4
10 20220103-V0
4. Mounting
4.1. General instructions
Use the enclosed seal when mounting DT9102 I4 on panel
to assure IP 65 protection between the instrument and the
panel from the front side (only panel mounting version).
Electrostatic hazard! Clean only a moist cloth and
detergent.
Mounting positions
Select a mounting position you can easily read the display
reach for mounting and connecting the instrument and that
minimises the hazard of water, dust or dump getting into the
instrument.
Mounting cable entries
The insrument is equipped with one M16x1.5 cable entry
and one additional hole equipped with sealing plugs. One
M16x1.5 cable entry is accessory. If required more than one
cable entry (see chapter 5.) put out the sealing plug turning
it in anticlockwise direction. To put in the cable entry use the
sealing turn it in clockwise direction. Tighten the screws so
much that ensures the desired sealing. Use only appropriet
tools.
Table of contents
Other Datcon Clock manuals
Popular Clock manuals by other brands
Silicon Laboratories
Silicon Laboratories SI5324 manual

Heathkit
Heathkit GC-1005 Assembly manual

Oregon Scientific
Oregon Scientific PRYSMA RMR221P manual

Andrew O'Malley
Andrew O'Malley DOTKLOK Assembly instructions

ALGE-Timing
ALGE-Timing ASC3 manual

Bodet
Bodet Profil 960 Installation and operating instructions

Progetti
Progetti KALIMERO Directions

La Crosse Technology
La Crosse Technology WT-3141b Quick setup instructions

La Crosse Technology
La Crosse Technology W86531 owner's manual

Sharp
Sharp SPC900 instruction manual

La Crosse Technology
La Crosse Technology 404-50447 quick start guide

Datexx
Datexx DF0063 quick guide