CFRC REMOTE CONTROLLER
2
For a large print version of these instructions
please call Marketing on 0845 121 7400.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other
printed material. All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
®
Certification Mark

Danfoss Heating 3
GB
Installation & User Instructions
CF-RC
Remote Controller
Index
1. Functional Overview ...................................................................... 4
2. Installation ....................................................................................... 4
3. Transmission Test ........................................................................... 5
4. Mounting.......................................................................................... 6
5. Menus................................................................................................ 6
5.1 Rooms.......................................................................................................6
5.2 Program....................................................................................................7
5.3 Setup......................................................................................................11
5.4 Alarms....................................................................................................13
6. Uninstallation ................................................................................14
7. Other products for the CF2 system and abbreviations .........14
8. Specifications.................................................................................14
9. Troubleshooting............................................................................15
10. Figures and illustrations ........................................................16-17

CFRC REMOTE CONTROLLER
4
GB
Note:
• Install the Remote Controller after you have installed all the Room
Thermostats, see fig. 5-b.
• Remove the strip to connect the enclosed batteries.
• Carry out the assignment of the Remote Controller to the Master
Controller within a distance of 1½m.
• When the back light in the display is out, the first touch of a button
only activates this light.
Activate Install mode on the Master Controller - fig. 3
• Use the menu selection button to select the Install mode.
The install LED flashes.
• Activate Install mode by pressing OK . The install LED goes
ON.
1. Functional Overview
Front – fig. 1
Display
Soft key 1
Soft key 2
Up/down selector
Left/right selector
Icon for system alarm
Icon for communication with Master Controller
Icon for switch to 230V power supply
Icon for low battery level
Note: The Remote Controller has a self-explanatory menu structure,
and all settings are easily carried out with the up/down and left/right
selectors in combination with the functions of the soft keys, which are
shown above them in the display.
Back – fig. 2
Back plate/docking station
Battery compartment
Screw hole for wall mounting
Screw and wall plug
Note: Remove the strip to connect the enclosed batteries.
2. Installation

Danfoss Heating 5
GB
3. Transmission Test
Activate Install mode on the Remote Controller - fig. 1
• When the batteries have been connected, follow the installation
guide, beginning with the selection of language.
• After the installation process, set time and date. Use the up/down
selector and the left/right selector to carry out the settings.
Confirm settings with OK activated by soft key 1 ().
• The installation process is concluded with the opportunity to
name the rooms in which the Room Thermostats are placed. This
makes access to and handling of the system very easy.
• In the Name rooms menu, activate the change menu with
soft key 2 () to change the default room names from e.g. MC1
Output 1.2 (Master Controller 1, output 1 and 2) to living room,
and confirm with OK. You can also use the spell…. menu to create
other names.
• When the installation is finished the start up screen will be shown
in the display with the actual time and date on the top. The screen
also shows the actual temperature in the room from the top of the
rooms list.
See chapter 5.3 to select another room for the start up screen.
Note: Keeping a button activated during settings will make the value
change faster.
Initiate a transmission test on the Remote Controller
From the start-up screen, activate the:
Link test menu to activate a test of the wireless transmission
between the Master Controller and the Remote Controller. The status
of the link test will be displayed right after the test has been carried
through.
If the link test is not successful:
• Try to relocate the Remote Controller in the room.
• Or install a Repeater Unit (CF-RU, see fig. 5 c), and place it between
the Master Controller and the Remote Controller.
Note: The link test may take a few minutes depending on the size of
the system.

CFRC REMOTE CONTROLLER
6
GB
4. Mounting
The Remote Controller has been installed – fig. 2
When the Remote Controller has been installed to the Master
Controller (see chapter 2), it can be mounted on the wall by means of
the back plate/docking station . The Remote Controller is powered
by two AA Alkaline 1.5V batteries.
• Before you place the back plate/docking station on the wall, verify
the transmission to the Master Controller from the desired location
by carrying out a link test (see chapter 3).
• Mount the back plate/docking station on the wall with the screws
and wall plugs .
• Place the Remote Controller in the docking station .
Note: To extend the transmission range of the CF2 system, up to three
Repeater Units can be installed in a chain – see fig. 4.
5. Menus
Note: When the back light in the display is out, the first touch of a button
only activates this light.
5.1 Rooms
From the start-up screen, activate the:
Rooms menu to access a list of all the rooms in the system. Select the
desired room with OK to enter the screen for that room. Here you can
see information about the set and actual temperatures:
: Indicates that this room is included in an ongoing time
programme (see chapter 5.2)
: Indicates that the Room Thermostat is running low on
battery
: Indicates that the value set on the RoomThermostat is beyond
the max./min. limitations set by the Remote Controller
: Indicates that the set temperature is above the actual
temperature
: Indicates that the set temperature is below the actual
temperature

Danfoss Heating 7
GB
5.1.1 Options
From the room screen, you can activate an Options menu with
access to several room options:
Set temperature:
Here you can set and lock the set temperature for the Room
Thermostat. Locking prevents adjustment of the set temperature on
the Room Thermostat.
Set Min/Max:
Here you can set and lock the minimum and maximum temperatures
for the Room Thermostat. Locking prevents adjustment beyond
these limits on the Room Thermostat.
Change room name:
Here you can change the room names by means of a list of possible
room names or you can use the spell..... menu to key in other
names.
Set floor Min/Max:
Here you can set and lock the minimum and maximum floor surface
temperatures.
Note: Only available with the Room Thermostat with infrared floor
sensor, CF-RF
Setback:
Here you can choose to override the next or ongoing setback period
(see chapter 5.2.2).
Cooling:
Here you can disable the cooling function for the room in question.
Note: Only available when the Master Controller is in cooling mode.
5.2 Program
From the start-up screen, activate the:
Program menu to view the two time programming options:

CFRC REMOTE CONTROLLER
8
GB
5.2.1 Period program:
With this program, you can set the room temperature for all Room
Thermostats during e.g. a holiday. The start and end date for the
program is easily set in a calendar by means of the up/down and
left/right selectors (fig. 1- /) and by confirming each setting with
OK. The room temperature and the duration of the period program
are illustrated and finally activated from a detailed overview for the
created program:
5.2.2 Setback program:
In the Program setback menu, you have the opportunity to divide
the different rooms into up to six different zones - each zone with up
to three different setback programs for reduced room temperature at
different times during the day.
Options:
Each zone has a screen showing the rooms included in the zone. This
provides access to an Options menu with an Add Room function
and three Setback programs (up to).
Add Room:
In this menu, all the rooms are followed by a ( ) indicating to what
zone each room has been allocated (see figure below ). As default,
all the rooms are assigned to Zone 1. If new zones are created, the
rooms will be moved from the zone to which they are allocated to the
new zone (from zone 1 to zone 3 in the figure below).

Danfoss Heating 9
GB
Program 1 - 3:
The Options menu also includes three possible setback programs for
each zone. By means of these, the seven days of the week can be
divided into up to three different setback programs with different days
and setback periods for each program. The procedure for creating or
changing a program is the same for all the three programs:
• Activate program (1- 3) from the Options menu with OK to select
the days for this program:
Use the up/down and left/right selectors (fig. 1-f/g) to select the
days for this program by moving them above the horizontal line.
Confirm with OK, and activate the next step to select the time for the
setback program.
Select the time for the setback program by setting the times for
the periods during which you want a normal room temperature,
indicated by the black bars cabove the time line (the periods
outside the black bars are the setback periods with reduced room
temperature). Set the start and end times by means of the left/right
selector and by toggling between them using the up/down selector
(fig. 1-f/g).
You can remove the second period with the normal room temperature
dby changing the end time of this period to its start time:

CFRC REMOTE CONTROLLER
10
GB
The second period with the normal room temperature d6can be
added again by means of the up/down selector and by toggling
through the first period e.
Confirm the selected time periods with OK to activate the created
program from this overview:
Note: The days selected in the program are indicated by more distinct
initial capitals.
Cancel program:
A created program can be deleted with the Cancel Program menu
leading to the overview illustrated above.
Note:
• In the Options menu, the created programs (1-3) will be indicated by
more distinct capitals.
• If you want to override a setback period in a room, you can do so with
the Override setback function in the Options menu for each room
(see chapter 5.1.1).
Setback temperature
In the Setback program (see chapter 5.2.2), activate the Setback
temperature menu to set the room temperature reduction from 1
to 10°C during setback periods.
Other manuals for CF-RC
2
Table of contents
Other Danfoss Remote Control manuals

Danfoss
Danfoss T70 1 HALL User manual

Danfoss
Danfoss CF-RC User manual

Danfoss
Danfoss FP975 Assembly Instructions

Danfoss
Danfoss MP08A User manual

Danfoss
Danfoss IKORE User manual

Danfoss
Danfoss Ikargo2 User manual

Danfoss
Danfoss MPCAN User manual

Danfoss
Danfoss 103E7 Assembly Instructions

Danfoss
Danfoss CF-RC User manual

Danfoss
Danfoss Ikompact User manual

Danfoss
Danfoss R13 F User manual

Danfoss
Danfoss 102E7 User manual

Danfoss
Danfoss 175G9004 User manual

Danfoss
Danfoss WS103 User manual

Danfoss
Danfoss SET3M User manual

Danfoss
Danfoss IKORE B User manual

Danfoss
Danfoss TM70 User manual

Danfoss
Danfoss IKP1000 User manual

Danfoss
Danfoss IK2 User manual

Danfoss
Danfoss R06 User manual