Daikin BRC1H63W User manual

Wired Remote
Controller
Installation Manual
MODEL BRC1H63W/BRC1H63K
+
-
• Be sure to read before conducting the installation of this product, and conduct
installation according to this manual.
• Refer to this manual together with the installation manual of the indoor unit.
It is possible to perform settings of some functions from
a smart phone app.

1
Contents
Safety Precautions ............................................................. 2
Components and Accessories............................................ 3
Remote Controller Installation Procedure........................... 4
Button Locations and Descriptions................................... 11
Overview of Screens ........................................................ 12
Setting Screen List ........................................................... 14
Names and Functions ...................................................... 16
Starting Up the System .................................................... 18
Switching the Changeover Master.................................... 21
Installer Menu................................................................... 25
Field Setting ..................................................................... 26
R/C Setting ....................................................................... 33
Installer Password Setting ................................................ 37
Other Service Settings ..................................................... 38
External Input Interlock..................................................... 39
Setting Up a Zigbee sensor.............................................. 45
Updated by OTA ............................................................... 52
License ............................................................................. 53
Certication ...................................................................... 54

2
Safety Precautions
Also refer to installation manual attached to the indoor unit.
Please read these “Safety Precautions” carefully before installing the remote controller.
• This manual classies the precautions into WARNINGS and CAUTIONS.
Be sure to follow all the precautions below: They are all important for ensuring safety.
WARNING Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury.
It may also be used to alert against unsafe practices.
• After completing installation, conduct a test operation to check for faults and explain to the customer
how to operate the remote controller and cleaning of it with the aid of the operation manual. Ask the
customer to store the installation manual along with the operation manual for future reference.
WARNING
Ask your dealer or qualied personnel to carry out installation work.
Do not attempt to install the remote controller yourself.
Improper installation may result in electric shocks or a re.
Consult your local dealer regarding relocation and reinstallation of the remote controller.
Improper installation may result in electric shocks or a re.
Install the remote controller in accordance with the instructions in this installation manual.
Improper installation may result in electric shocks or a re.
Be sure to use only the specied accessories and parts for installation work.
Failure to use the specied parts may result in the remote controller falling down, electric shocks or a
re.
Install the remote controller on a foundation that can withstand its mass.
Insufcient strength may result in the remote controller falling down and causing injury.
Make certain that all electrical work is carried out by qualied personnel according to the applicable
legislation (note 1) and this installation manual, using a separate circuit.
In addition, even if the wiring is short, make sure to use a wiring that has sufcient length and never
connect additional wiring to make the length sufcient.
Insufcient capacity of the power supply circuit or improper electrical construction may lead to
electric shocks or a re.
(note 1) applicable legislation means “All international, national and local directives, laws, regulations
and/or codes which are relevant and applicable for a certain product or domain”.
Turn off the power before performing installation work.
Touch with live parts may cause electric shocks.
Do not disassembly, reconstruct or repair.
Electric shock or a re may cause.
Make sure that all wiring is secured, using the specied wirings and ensuring that external forces do
not act on the terminal connections or wirings.
Improper connections or xing may cause an overheat or a re.
The choice of materials and installations must comply with the applicable national and international
standards.

3
CAUTION
To avoid electric shocks due to entry of water or insects, ll the wiring through hole with putty.
Do not operate with wet hands to avoid electric shocks.
Do not wash the remote controller with water.
It may result in electric shocks or a re.
Install the air conditioner, power supply wiring, remote controller wiring and transmission wiring at
least 1 meter away from televisions or radios to prevent image interference or noise.
(Depending on the radio waves, a distance of 1meter may not be sufcient to eliminate the noise.)
Do not install the remote controller in the following locations:
1. Where there is oil mist, oil spray or vapour for example a kitchen.
Resin parts may deteriorate and fall off.
2. Where corrosive gas, such as sulphurous acid gas, is produced.
3. Where there is machinery which emits electromagnetic waves.
Electromagnetic waves may disturb the control system, and cause a malfunction of the equipment.
4. Where ammable gas may leak, where there is carbon bre or ignitable dust suspensions in
the air, or where volatile ammables such as thinner or gasoline are handled.
Operating the unit in such conditions may result in a re.
5. High temperature area or directly amed point.
It may cause an overheat or a re.
6. Moist area, or place where may be exposed to water.
If water enters inside of the remote controller, electrical components may fail.
It may result in electric shocks or a re.
When remote controller’s thermostat sensor is used, select the installation location considering the
followings.
• A place where average temperature in the room can be detected.
• A place where is not exposed to direct sunlight.
• A place where is far apart from heat source.
• A place where is not affected by outdoor air due to door opening/closing or the like.
Components and Accessories
The following components are included.
Upper casing Back plate
+
-
(1 pc.) (1 pc.)
The following accessories are included.
Cross recessed round
head wood screw Drywall anchor Operation Handbook Installation Handbook
(2 pcs.) (2 pcs.) (1 pc.) (1 pc.)

4
Remote Controller Installation
Procedure
Deciding where to install the remote controller
Select the installation location based on “Safety Precautions” and obtain consent of the
customer.
Creating a wiring through-hole in the wall (when opening a
hole in the wall and installing)
If the hole size is too large or not in the
proper location, it may be seen after the
remote controller is installed.
NOTE
3-11/64 (80.5)
13/64
(5)
33/64 (13)
1-47/64 (44)
9/32 (7)
R3/32(2.5)
R3/32(2.5)
13/64
(5)
41/64
(16.25)
1-47/64 (44)
35/64
(13.75)
3-11/64 (80.5) Back plate
Through-hole
Align the centre of the wall
hole with the centre of the
access hole on the controller
back plate when planning the
installation.
Access hole
[Unit : inch (mm)]
Back plate
Through-hole
Access
hole
CAUTION
• Note that if the wiring through-hole is large or deviates from the specied position, the hole may be
exposed.

5
Determining the wire routing direction for the back plate
Before mounting the controller, determine the wiring direction and remove a piece of the
controller’s back plate accordingly (i.e.: a, b, c). The wiring can be routed from the top, the
left, or the bottom of the back cover. Remove a piece of the back plate according to the
following gure.
After removing a thin piece with a tool such as clippers, remove burrs using a le, etc.
a Wiring from top
b Wiring from left
c Wiring from bottom
a
b
c
CAUTION
In case you are routing the wiring from the rear, you don’t have to remove anything.
When routing the wiring from the top, rear, left, or bottom, be sure to route the wiring to the upper
casing before securing the back plate.

6
Securing the back plate
Wall installation
1 : Take the cross recessed round head wood screws and drywall anchors out of the
accessory bag.
2 : Mount the back plate to a at surface.
Cross recessed round
head wood screws
Drywall anchors
CAUTION
• Install the controller on a at surface only.
• To prevent deformation of the back plate, avoid over-tightening the installation screws.
• If tightened too much, the back plate will be deformed and the upper casing will come o easily.
If the upper casing comes o easily, loosen the screws and correct the deformation.

7
Connecting the electrical wiring
All wiring must comply with the following requirements:
Wire specification Value
Wiring type Non-shielded, 2-conductor, Stranded copper wire
Wiring size AWG-18
Wiring length Maximum 1640 feet (500 m)
Prepare the wiring for connection to the remote controller following these instructions:
Approx. 3/8 inch (10 mm)
Remove the wire jacket
and insulation
To simplify the wiring, maintain
a 3/8 inch (10 mm) dierence
between the length of the two
conductors.
Cutting guideline
L
Wiring outlet L
Top 5.5 inch (140 mm)
Left 4.3 inch (110 mm)
Bottom 3.5 inch (90 mm)
Rear No requirements
Connect the terminals (P1, P2) of the remote controller to the terminals (P1, P2) of the
indoor unit. (P1 and P2 are not polarity sensitive.)
CAUTION
• Before working, shut o all power supplies.
• A mounting plate for installing the remote controller and remote controller wiring are not included.
• Do not touch the remote controller circuit board directly with your hands.

8
Top outlet
P1P2
P1P2 terminal
Rear outlet
P1P2
Left outlet
P1P2

9
Bottom outlet
P1P2
CAUTION
• Keep the wiring away from the power wire so that electrical noise (external noise) is not received.
• In order to prevent the entry of water or insects, use putty (eld supply) to securely seal the wiring
lead-in hole.
Closing the controller
1 : Place the top of the controller on the
top of the back plate.
2 : Snap the bottom of the controller into
place on the bottom of the back plate.
3 : Ensure the installation site is dust-free,
before peeling the protective seal.
1
2
CAUTION
• Never touch the internal parts of the controller.
• When closing the controller, be careful not to pinch the wiring.
• To prevent damage, make sure the front of the controller is clicked into the back plate securely.
This manual suits for next models
1
Table of contents
Other Daikin Remote Control manuals

Daikin
Daikin BRC1D71 User manual

Daikin
Daikin BRC1H62W User manual

Daikin
Daikin Madoka BRC1HHDW User manual

Daikin
Daikin BRC1E51 User manual

Daikin
Daikin BRC7EA628 User manual

Daikin
Daikin BRC7E830 User manual

Daikin
Daikin BRC52B61 User manual

Daikin
Daikin BRC52B61 User manual

Daikin
Daikin BRC1H71W System manual

Daikin
Daikin BRC1H51W User manual

Daikin
Daikin BRC1D517 User manual

Daikin
Daikin BRC7C812 User manual

Daikin
Daikin BRC1D61 User manual

Daikin
Daikin BRC1H51W User guide

Daikin
Daikin BRC1E73 User manual

Daikin
Daikin BRC1E52B7 User manual

Daikin
Daikin G17 User manual

Daikin
Daikin BRC1D52 User manual

Daikin
Daikin BRCW901A03 Manual

Daikin
Daikin 4PW71247-1-KAD User manual