Be sure to read this installation manual before
installing this product.
On/Off
Mode
Fan
Speed
Cancel
Menu
OK
MODEL BRC1E73
WIRED REMOTE
CONTROLLER
INSTALLATION MANUAL
Veillez à lire ce manuel d’installation avant
d’installer ce produit.
Asegúrese de leer este manual de instalación
antes de instalar este producto.
00_CV_3P243521-7L.indd 100_CV_3P243521-7L.indd 1 11/13/2014 1:53:15 PM11/13/2014 1:53:15 PM


English 1
Contents
1. Safety Considerations ...................... 2
2. Accessories ....................................... 4
3. Remote Controller Installation
Procedure .......................................... 4
4. Functions and Menu Items
of Remote Controller Buttons........ 10
5. Power-on.......................................... 12
6. Field Settings .................................. 13
7. Test Operation ................................. 15
8. Procedure for Checking
Error History .................................... 18
9. Adding Maintenance Contact
Information ...................................... 19
10. Confirming Registered Details ...... 20
11. Clock & Calendar ............................ 20
12. Language ......................................... 21
01_EN_3P243521-7L.indd 101_EN_3P243521-7L.indd 1 10/31/2014 4:56:39 PM10/31/2014 4:56:39 PM

2 English
Safety Considerations1.
The original instructions are written in English. All other languages are translations of the original
instructions.
All phases of the field-installation, including, but not limited to, electrical, piping, safety, etc. must be in
accordance with manufacturer’s instructions and must comply with national, state, provincial and local
codes.
Read these SAFETY CONSIDERATIONS carefully before installing the remote controller.
After completing the installation, ensure that the remote controller operates properly during the startup
operation.
Train the customer to operate and maintain the remote controller. Inform customers that they should
store this Installation Manual with the Operation Manual for future reference.
Always use a licensed installer or contractor to install this product. Improper installation can result in
electrical shock, fire, or explosion.
Meanings of WARNING, CAUTION, and NOTE Symbols.
WARNING Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury.
It may also be used to alert against unsafe practices.
NOTE Indicates situations that may result in equipment or property-damage
accidents only.
WARNING
Only qualified personnel must carry out the installation work.
Consult your Daikin dealer regarding relocation and reinstallation of the remote controller.
Improper installation work may result in electric shocks or fire.
Electrical work must be performed in accordance with relevant local and national regulations and
with instructions in this installation manual.
Improper installation may cause electrical shocks or fire.
Use only specified accessories and parts for installation work.
Failure to use specified parts may result in electric shocks, fire, or the unit falling.
Do not disassemble, reconstruct, or repair.
Electric shock or fire may occur.
Make sure that all wiring is secured, that specified wires are used, and that no external forces act on
the terminal connections or wires.
Improper connections or installation may result in fire.
Before touching electrical parts, confirm the power-off to the unit.
01_EN_3P243521-7L.indd 201_EN_3P243521-7L.indd 2 10/31/2014 4:56:39 PM10/31/2014 4:56:39 PM

English 3
CAUTION
Keep water out of the remote controller.
To avoid electric shock due to entry of water or insects, fill the wiring through-hole with putty.
Do not wash the remote controller with water as it may result in electrical shocks or fire.
Do not touch the remote controller buttons with wet fingers.
Touching the buttons with wet fingers can cause an electric shock.
Do not install the remote controller in the following locations:
Where a mineral oil mist or oil spray or vapor is produced, for example, in a kitchen.(a)
Plastic parts may deteriorate.
Where corrosive gas, such as sulfurous acid gas, is produced.(b)
Near machinery emitting electromagnetic waves.(c)
Electromagnetic waves may disturb the operation of the control system and cause the unit to
malfunction.
Where flammable gas may leak, where there is carbon fiber or ignitable dust suspensions in the(d)
air, or where volatile flammables such as thinner or gasoline are handled.
Operating the unit in such conditions can cause a fire.
High temperature area or direct flame.(e)
Overheating and/or fire can occur.
Moist area, where there is exposure to water. If water enters the inside of the remote controller,(f)
it may cause electric shock and electrical components may fail.
NOTE
Install the control wires for the indoor and the remote controller at least 3.5 feet (1 meter) away from
televisions or radios to prevent image interference or noise. Depending on the radio waves, a
distance of 3.5 feet (1 meter) may not be sufficient to eliminate the noise.
When remote controller’s temperature sensor is used, select the installation location as per the
following:
A place where average temperature in the room can be detected.●
A place where it is not exposed to direct sunlight.●
A place where it is far away from any heat source.●
A place where it is not affected directly by outside air.●
01_EN_3P243521-7L.indd 301_EN_3P243521-7L.indd 3 10/31/2014 4:56:39 PM10/31/2014 4:56:39 PM

4 English
Accessories2.
The following accessories are included.
Drywall screw Drywall anchor Wire tie Operation
manual
Installation
manual Wiring retainer
(2 pcs.) (2 pcs.) (1 pc.) (1 pc.) (1 pc.) (1 pc.)
Remote Controller Installation Procedure
3.
Determine where to install the remote controller.3-1
Make sure to follow the Safety Considerations when determining the location.
If the control wire for the remote controller is to be routed3-2
from the rear, consider the location of the access hole in the
lower case for making a hole in the wall.
Align the center of the wall
hole with the center of the
access hole on the controller
lower case when planning the
installation.
F5/16-3/8
External view of the remote controller
[Unit : inch]
Access
hole
F5/16-3/8
Lower case
Through-hole
1-15/16
1-9/16
Remove upper case.3-3
Insert a screwdriver in the recess of lower case to remove the upper case (2 points).
Upper case
Lower case
Screwdriver
Insert and twist the screwdriver
lightly for removal.
Remote controller printed-circuit
board is installed on the upper case.
Be careful not to damage the
printed-circuit board with the
screwdriver.
Be careful not to let dust or moisture
touch the printed-circuit board.
If the hole size is too large or not in the proper
location, it may be seen after the remote
controller is installed.
NOTE
01_EN_3P243521-7L.indd 401_EN_3P243521-7L.indd 4 10/31/2014 4:56:40 PM10/31/2014 4:56:40 PM

English 5
Determine the location where the wiring will enter the3-4
remote controller (back, left side, top left, top center).
Back outlet3-4-1 Left outlet3-4-2
Cut off resin area (notched area). Cut the plastic at the notched area and
remove any remaining burrs.
Top left outlet3-4-3 Top center outlet3-4-4
Cut the plastic at the notched area and
remove any remaining burrs.
Cut the plastic at the notched area and
remove any remaining burrs.
Install wiring.3-5
1. Switch box and control wiring are filed supplied.
Do not touch the remote controller printed-circuit board.2.
NOTE
Wiring Specifications
Wiring Type Non-shielded, 2-conductor, stranded copper wire
Wiring Size AWG-18
Wiring Length Maximum 1640 feet (500m)
01_EN_3P243521-7L.indd 501_EN_3P243521-7L.indd 5 10/31/2014 4:56:40 PM10/31/2014 4:56:40 PM

6 English
Prepare the wiring for connection to the remote controller following these instructions:
Remove the wire jacket
and insulation
Cutting guideline
Approx. 3/8 inch
To simplify the wiring, maintain
a 3/8in difference between the
length of the two conductors.
Length of jacket to be removed:
Approx. 6 inch for top left outlet●
Approx. 8 inch for top center outlet●
Connect the terminals (P/P1, N/P2) of the remote controller to the terminals (P1, P2) of the
indoor unit. (P1 and P2 are not polarity sensitive.)
Back outlet3-5-1
<Wire attachment guideline>
Lower case
P1
Indoor unit
P2
Upper case
Wire tie
Wire attachment
point
Printed-circuit
board
Cross-section -
Secure the wire at the
attachment point by
using furnished wire
tie.
Wire tie
01_EN_3P243521-7L.indd 601_EN_3P243521-7L.indd 6 10/31/2014 4:56:41 PM10/31/2014 4:56:41 PM

English 7
Left outlet3-5-2
Lower case
Upper case
Indoor unit
P1P2
Printed-circuit
board
Top left outlet3-5-3
As shown to the left,
install the furnished
wiring retainer to
prevent the wires
from being pinched
during installation.
Indoor unit
Wiring retainer Wiring retainer
Upper case
Lower case
Upper case
Wire
Cross-section -
P1P2
Printed-
circuit board
Top center outlet3-5-4
Indoor unit
Wiring retainer
Upper case
Lower case
P1P2
Printed-circuit
board
01_EN_3P243521-7L.indd 701_EN_3P243521-7L.indd 7 10/31/2014 4:56:41 PM10/31/2014 4:56:41 PM

8 English
●To prevent electrical noise and possible communication errors, avoid installing the
remote controller wiring parallel to or in the vicinity of line voltage circuits.
NOTE
Installation procedure for the lower case.3-6
When wiring the remote controller through the top center or rear access points, attachment of the
wire to the lower case is required before it is wall mounted. Closely follow the wiring
procedures.
Wall installation3-6-1
Secure by using furnished drywall anchors and screws (2 pcs.).
Drywall screws
Drywall anchors
Switch box installation3-6-2
Secure by using field supplied machine screws (2 pcs.).
Machine screws (field supply) or
(use optional accessory KJB211A)
Switch box
(field supply) or
(use optional accessory
KJB211A)
Switch box
[Unit : inch]
3-5/16
1-13/16
●Install the control on a flat surface only.
To prevent deformation of the lower case, avoid over-tightening the installation screws.●
NOTE
01_EN_3P243521-7L.indd 801_EN_3P243521-7L.indd 8 10/31/2014 4:56:42 PM10/31/2014 4:56:42 PM
Other manuals for BRC1E73
3
Table of contents
Languages:
Other Daikin Remote Control manuals

Daikin
Daikin BRC7FA532F User manual

Daikin
Daikin BRC51D64 User manual

Daikin
Daikin BRC1D528 User manual

Daikin
Daikin BRC1H71W User manual

Daikin
Daikin RXN-L9 User manual

Daikin
Daikin BRC52B61 User manual

Daikin
Daikin BRC7E530W8 User manual

Daikin
Daikin BRC230Z8A User manual

Daikin
Daikin Madoka User manual

Daikin
Daikin ARC423A17 User manual

Daikin
Daikin T9000 Manual

Daikin
Daikin BRC7E818 User manual

Daikin
Daikin OH08-1 User manual

Daikin
Daikin BRC7C62 User manual

Daikin
Daikin BRC1H519W7 User guide

Daikin
Daikin Siesta ARCWLA User manual

Daikin
Daikin G17 User manual

Daikin
Daikin BRC7EA631 User manual

Daikin
Daikin BRC1E72 User manual

Daikin
Daikin BRC1H71W User manual