Crow EDS-3000 Mounting instructions

1
ELECTRONIC ENGINEERING LTD.
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
&
&&
&
USER MANUAL
USER MANUALUSER MANUAL
USER MANUAL
P/N 7101691 Rev. A
EDS
EDSEDS
EDS-
--
-3000
30003000
3000
Outdoor Double Optics PIR +
Outdoor Double Optics PIR + Outdoor Double Optics PIR +
Outdoor Double Optics PIR +
MW detector with Pet immune
MW detector with Pet immuneMW detector with Pet immune
MW detector with Pet immune
alarm shop

2
alarm shop

3
1 General...................................................................................................................................... 5
2 Features .................................................................................................................................... 5
3 Assembly description................................................................................................................. 6
4 Detection Pattern....................................................................................................................... 7
5 Selecting mounting location....................................................................................................... 8
6 Detector Installation................................................................................................................... 9
7 Terminal Block Connections.................................................................................................... 11
7.1 Wire Size Requirements................................................................................................... 11
8 Settings & Adjustments ........................................................................................................... 12
8.1 Detection beam direction.................................................................................................. 12
8.2 Detection range setting ....................................................................................................12
8.3 Sensitivity, Range and Pet immune Adjustment............................................................... 13
8.4 Indications setting............................................................................................................. 14
9 Operation................................................................................................................................. 15
10 Test procedure..................................................................................................................... 16
11 Specifications....................................................................................................................... 17
alarm shop

4
alarm shop

5
1 General
The EDS-3000 is unique Passive Infra-Red and Microwave detector for outdoor and harsh
environment applications.
The EDS-3000 is designed for outdoor usage in most severe and extreme acclimate conditions
that may also accommodate pets.
High reliability is achieved by combining both dual tech hardware with highly sophisticated
software as well as an adaptive coverage area, reducing false alarms alerts to zero.
It comprises of Double Optics and advanced MW Detector inside stylist rigid plastic body.
This special optics combined with state of the art MW Doppler sensor assures elimination of
“false alarms” while maintaining high security standards for the detection of human intruders into
protected area.
The detection sensitivity and range is controlled by digital rotary switch allowing 16 calibration
levels, so that the effective pattern will be set for every installation environment and protection
site.
The EDS-3000 is designed to protect large areas and can easily be installed on walls in order to
provide a solid protection of the area while rejects interferences from birds and small animals due
to “PET MASK” optics.
2 Features
• MW detection based on Doppler concept.
• N.O. & N. C. Relays switched at the same time.
• Height installation calibrations free, from 0.8m to 1.5m (2.6 ft to 4.9 ft)
• Selectable pet immunity between 20kg and 35kg (44 lbs to 77 lbs)
• 16 levels of PIR sensitivity adjustment including 3 MW sensitivity groups.
• Temperature compensation.
• Micro controller signal processing.
• Front and back tamper protection.
• Sound indication for walk test and intruder detection.
• Unique waterproof and seal plastic design.
• Detection Range: Up to 18m (59 ft)
• Detect human intruders walking or running.
• No maintenance required.
• High RFI/EMI Immunity.
• Protection from: direct sunlight, wind up to 30 m/sec, snow and rain, small animals, removing
the top cover, housing pulling out or destruction
alarm shop

6
3 Assembly description
The EDS-3000 is a robust detector which includes big indication led prism that can be easily
observed from long distance. Having a back metal bracket, the EDS-3000 can be easily mounted
to walls and poles using mounting screws or metal bands (supplied).
The EDS-3000 is combined of three detection elements:
Upper PIR element
Lower PIR element
Microwave element
The upper PIR element has an adjustable detection height while the other two are fixed.
The following drawing shows all internal elements:
Upper PIR element
Lower PIR element
Mi
c
r
owave
e
l
e
m
e
n
t
LED
Terminal Connection Blocks
LED and Buzzer dipswitches
Sensitivity setting
Direction An
g
le Indicato
r
Range setting handle
Range Indication
Tamper switch
Bracket locking screw
alarm shop

7
4 Detection Pattern
The EDS-3000 has a 90° top view PIR and MW detection pattern with over 18m (59 ft) detection
distance (when installed at 1.2m (4 ft) above the ground surface).
The EDS-3000 has an internal rotating housing (which includes the 2 PIR elements and the MW)
that can be adjusted horizontally, so its 90° coverage may vary between 0° and 180°.
The EDS-3000 can differentiate between pets and human bodies and alert accordingly by
having MW movement detection combined with two PIR detection beams:.
A. Lower PIR element which is fixed to 18m range and 60cm above ground level which helps
avoiding pets detection over the entire area.
B. Upper PIR element which has adaptive range between 3 and 18m.
By having both PIR detection beams and MW detection the crossing object will be defined as
intrusion, causing an alarm.
In case of MW detection with only one of the beams
no alarm will be generated.
Detection area
Upper PIR element detection pattern
Adjustable between 3m and 18m (10 ft to 59 ft)
Lower PIR element detection pattern
Fixed to 18m (59 ft) range
Microwave detection pattern Detection No Detection
No pet detection in
all protected area
alarm shop

8
5 Selecting mounting location
The installation of the EDS-3000 requires straight and solid base for the detector and setting of
front panel against the center of protected area.
The protected area must be free from obstacles like walls, fences, trees, ditches and other
microwave detectors, as well as systems of anti-intrusion surveillance.
The bracket provides EDS-3000 installation on a wall or pole. The wall or pole should be leveled.
Choose a location most likely to intercept an intruder according to detection pattern on page 6.
Avoid the following Installation Locations:
• Facing direct sunlight.
• Facing areas subject to rapid temperature changes.
• Wall angle of more than 10º from perpendicular line.
• Mounting at more than 10º Deviation from horizontal line.
• Facing metal doors.
• Do not install near direct source of heat or air gust.
• Clear all physical obstacles from the detection area
(e.g. Plants, laundries, etc.)
• Clear all light reflecting surfaces from the detection area,
as well as water puddles.
• Avoid installation on the following types of ground:
Thick vegetation, Grass (un-mown), Water, Sand and Metal.
NOTE:
Recommended installation height is 1.2m (4 ft).
** If there is a risk of tall pets (over 60cm / 2 ft) the detector is to be installed at 1.4m (4.5 ft).
The DOUBLE DUAL high quality sensor detects motion crossing the beam; it is less sensitive
detecting motion towards the detector.
The EDS-3000 performs best when provided with a constant and stable environment.
In order to ensure suitable operation of the EDS-3000 type of ground should be one of the
following: Asphalt concrete, Cement, Soil, Clay, Gravel or Grass (mown).
alarm shop

9
6 Detector Installation
Important! Prior to installation, read both “Operation” and “Selecting the mounting location”
sections carefully.
1. Install the detector in such manner that the intruder
is most likely to cross the detection area from side to
side.
2. The detector is to be installed at height of 0.8 to 1.5
meter (2.6 to 4.9 ft)
3. Make sure to attach the metal bracket to a leveled
straight and firm wall, leaving 15cm (6 inches) from
the top and 15cm (6 inches) from both sides, for easy
installation and maintenance.
4. Rotating the detection beam may be required for
guarding a side window opening while the detector is
installed facing another direction.
5. Open the detector unwinding the bottom screw.
6. Release the rear metal bracket by unwinding
internal bottom screw.
7. Release the detector body from the metal bracket
by polling front and up.
8. Attach the rear bracket to the wall or a pole using
mounting screws or metal bands.
alarm shop

10
9. Break the relevant rear knockouts on plastic base
rear side for your installation and slide the wires from
the outside via the paths and knockout to the internal
side of the detector.
10. Attach the sealing “U” shaped Sponge Pad to the
wire opening from the rear side after the wires
connection and prior to final product affixing to the
mounted bracket.
11. Place the detector on the mounting bracket from top
side down and then lock the screw at the bottom.
12. Connect the wires to the terminal blocks
according to the following chapter.
alarm shop
Table of contents