Burkert 8025 UNIVERSAL User manual

Quickstart
Type 8025
UNIVERSAL
English - Deutsch - Français

We reserve the right to make technical changes without notice.
Technische Änderungen vorbehalten.
Sous réserve de modifications techniques.
© Bürkert SAS, 2012 - 2019
Operating Instructions_1903/04 00564360 ORIGINAL_FR

3
1 ABOUT THE QUICKSTART .....................................................................4
2 INTENDED USE .............................................................................................5
3 BASIC SAFETY INFORMATION ............................................................5
4 GENERAL INFORMATION ........................................................................6
5 DESCRIPTION OF THE RATING PLATE ............................................7
6 TECHNICAL DATA ........................................................................................7
7 INSTALLATION AND WIRING ..............................................................11
8 ADJUSTMENT AND COMMISSIONING ....................................................37
9 PACKAGING, TRANSPORT .................................................................. 46
10 STORAGE ...................................................................................................... 46
11 DISPOSAL OF THE DEVICE ................................................................ 46
Type 8025 UNIVERSAL
English

4
About the Quickstart
Type 8025 UNIVERSAL
CAUTION
Warns against a possible risk.
▶▶Failure▶to▶observe▶this▶warning▶can▶result▶in▶substantial▶or▶minor▶
injuries.▶
NOTICe
Warns against material damage.
Indicates▶additional▶information,▶advice▶or▶important▶
recommendations.▶
Refers▶to▶information▶contained▶in▶these▶Quickstart▶or▶in▶
other▶documents.▶
▶▶Indicates▶an▶instruction▶to▶be▶carried▶out▶to▶avoid▶a▶danger,▶a▶
warning▶or▶a▶possible▶risk.
▶→Indicates▶a▶procedure▶to▶be▶carried▶out.▶
1.2 Definition of the word "device"
The▶word▶"device"▶used▶within▶this▶Quickstart▶refers▶to▶the▶trans-
mitter▶type▶8025▶UNIVERSAL▶with▶serial▶numbers▶higher▶or▶equal▶to▶
20▶000.▶
1 ABOUT THE QUICKSTART
The▶Quickstart▶describes▶the▶life▶cycle▶of▶the▶device.▶Please▶keep▶
this▶Quickstart▶in▶a▶safe▶place,▶accessible▶to▶all▶users▶and▶any▶new▶
owners.▶
The Quickstart contains important safety information.
Failure▶to▶comply▶with▶these▶instructions▶can▶lead▶to▶hazardous▶
situations.▶Pay▶attention▶in▶particular▶to▶the▶chapters▶"3▶Basic▶
safety▶information"▶and▶"2▶Intended▶use".▶
▶▶Whatever▶the▶version▶of▶the▶device,▶this▶Quickstart▶must▶be▶
read▶and▶understood.▶
The▶Quickstart▶explains▶how▶to▶install,▶set,▶and▶start-up▶the▶device.
A▶detailed▶description▶of▶the▶device▶can▶be▶found▶in▶the▶related▶
Operating▶Instructions▶available▶on▶the▶internet▶under:▶
▶www.burkert.com▶
1.1 Symbols used
DANger
Warns against an imminent danger.
▶▶Failure▶to▶observe▶this▶warning▶results▶in▶death▶or▶in▶serious▶injury.▶
WArNINg
Warns against a potentially dangerous situation.
▶▶Failure▶to▶observe▶this▶warning▶can▶result▶in▶serious▶injury▶or▶
even▶death.▶
English

5
Intended use
Type 8025 UNIVERSAL
2 INTENDED USE
Use of the device that does not comply with the instructions
could present risks to people, nearby installations and the
environment.
The▶transmitter▶8025▶UNIVERSAL▶has▶been▶designed▶to▶process▶
a▶frequency▶signal,▶received▶from▶a▶flow▶sensor▶connected▶to▶the▶
transmitter.▶
▶▶Use▶the▶device▶in▶compliance▶with▶the▶characteristics▶and▶
commissioning▶and▶use▶conditions▶specified▶in▶the▶contractual▶
documents▶and▶in▶the▶Operating▶Instructions.▶
▶▶Never▶use▶the▶device▶for▶security▶applications.▶
▶▶Use▶the▶device▶only▶in▶combination▶with▶foreign▶devices▶or▶for-
eign▶components▶recommended▶or▶approved▶by▶Bürkert.▶
▶▶Protect▶the▶device▶against▶electromagnetic▶interference,▶ultra-
violet▶rays▶and,▶when▶installed▶outdoors,▶the▶effects▶of▶climatic▶
conditions.▶
▶▶Only▶operate▶a▶device▶in▶perfect▶working▶order.
▶▶Store,▶transport,▶install▶and▶operate▶the▶device▶properly.▶
▶▶Only▶use▶the▶device▶as▶intended.▶
3 BASIC SAFETY INFORMATION
This▶safety▶information▶does▶not▶take▶into▶account▶any▶contingencies▶
or▶occurrences▶that▶may▶arise▶during▶installation,▶use▶and▶mainte-
nance▶of▶the▶device.▶
The▶operating▶company▶is▶responsible▶for▶the▶respect▶of▶the▶local▶
safety▶regulations▶including▶for▶the▶staff▶safety.▶
Danger due to electrical voltage.
▶▶If▶a▶12...36▶V▶DC▶energized▶version▶is▶installed▶either▶in▶a▶wet▶
environment▶or▶outdoors,▶all▶the▶electrical▶voltages▶must▶be▶of▶
max.▶35▶V▶DC.▶
▶▶Before▶carrying▶out▶work▶on▶the▶system,▶disconnect▶the▶electri-
cal▶power▶for▶all▶the▶conductors▶and▶isolate▶it.▶
▶▶All▶equipment▶connected▶to▶the▶device▶must▶be▶double▶insu-
lated▶with▶respect▶to▶the▶mains▶according▶to▶the▶standard▶IEC▶
61010-1:2010.▶
▶▶Observe▶all▶applicable▶accident▶protection▶and▶safety▶regula-
tions▶for▶electrical▶equipment.▶
Various dangerous situations
To▶avoid▶injury:▶
▶▶Do▶not▶use▶the▶device▶in▶explosive▶atmospheres.▶
▶▶Do▶not▶use▶the▶device▶in▶an▶environment▶incompatible▶with▶the▶
materials▶it▶is▶made▶of.▶
▶▶▶Do▶not▶subject▶the▶device▶to▶mechanical▶stress.▶
English

6
General information
Type 8025 UNIVERSAL
Various dangerous situations
To▶avoid▶injury:▶
▶▶Do▶not▶make▶any▶modifications▶to▶the▶device.▶
▶▶Prevent▶any▶unintentional▶power▶supply▶switch-on.▶
▶▶Only▶qualified▶and▶skilled▶staff▶can▶carry▶out▶the▶installation▶and▶
maintenance▶work.▶
▶▶Guarantee▶a▶defined▶or▶controlled▶restarting▶of▶the▶process,▶
after▶a▶power▶supply▶interruption.▶
▶▶Observe▶the▶general▶technical▶rules.▶
NOTICe
Elements / Components sensitive to electrostatic discharges
The▶device▶contains▶electronic▶components▶sensitive▶to▶electro-
static▶discharges.▶They▶may▶be▶damaged▶if▶they▶are▶touched▶by▶an▶
electrostatically▶charged▶person▶or▶object.▶In▶the▶worst▶case▶sce-
nario,▶these▶components▶are▶instantly▶destroyed▶or▶go▶out▶of▶order▶
as▶soon▶as▶they▶are▶activated.▶
▶▶To▶minimise▶or▶even▶avoid▶all▶damage▶due▶to▶an▶electrostatic▶
discharge,▶take▶all▶the▶precautions▶described▶in▶standard▶
EN▶61340-5-1.▶
▶▶Also▶ensure▶that▶you▶do▶not▶touch▶any▶of▶the▶live▶electrical▶
components.▶
4 GENERAL INFORMATION
4.1 Manufacturer's address and
international contacts
To▶contact▶the▶mannufacturer▶of▶the▶device,▶use▶following▶address:▶
Bürkert▶SAS▶
Rue▶du▶Giessen▶
BP▶21▶
F-67220▶TRIEMBACH-AU-VAL▶
You▶may▶also▶contact▶your▶local▶Bürkert▶sales▶office.▶
The▶addresses▶of▶our▶international▶sales▶offices▶are▶available▶on▶the▶
internet▶at:▶www.burkert.com▶
4.2 Warranty conditions
The▶condition▶governing▶the▶legal▶warranty▶is▶the▶conforming▶use▶of▶
the▶device▶in▶observance▶of▶the▶operating▶conditions▶specified▶in▶the▶
Operating▶Instructions.▶
4.3 Information on the Internet
You▶can▶find▶the▶Operating▶Instructions▶and▶technical▶data▶sheets▶
regarding▶the▶type▶8025▶UNIVERSAL▶at:▶www.burkert.com▶
English

7
Description of the rating platE
Type 8025 UNIVERSAL
5 DESCRIPTION OF THE RATING PLATE
LFLOW 8025 PANEL SUPPLY: 12-36V... 210 mA
DO1: 5-36V... 100mA AO1:4-20mA
DO2&3: 2xRelay 30V and 42V peak or 60V... max. IP20
S/N 20 000
00564417 W46MA
Made in France
1
11
6
7
8
1213
35
10
4
2
9
1.▶ Measured▶value▶
2.▶ Type▶of▶the▶device,▶housing▶
3.▶ Specifications▶of▶the▶digital▶output▶DO1▶(transistor)▶
4.▶ Specifications▶of▶the▶analogue▶output▶AO1▶
5.▶ Supply▶voltage▶and▶max.▶current▶consumption▶
6.▶ Protection▶class▶of▶the▶device▶
7.▶ Manufacturing▶code▶
8.▶ Conformity▶marking▶
9.▶ Certification
10.▶Warning:▶Before▶using▶the▶device,▶take▶into▶account▶the▶tech-
nical▶specifications▶described▶in▶this▶Quickstart.▶
11.▶Specifications▶of▶the▶relay▶outputs▶DO2▶and▶DO3▶
12.▶Serial▶number▶
13.▶Article▶number
Fig. 1 : Rating plate of the device (example)
6 TECHNICAL DATA
6.1 Conditions of use
Ambiant temperature –10...+60▶°C▶
Air humidity <▶80▶%,▶non▶condensated▶
Height above see level max.▶2000▶m▶
Operating conditions Continuous▶operation
Equipment mobility Fixed▶device
Use Indoor▶and▶outdoor▶▶
(Protect▶the▶device▶against▶electro-
magnetic▶interference,▶ultraviolet▶rays▶
and,▶when▶installed▶outdoors,▶against▶
the▶effects▶of▶climatic▶conditions)
Installation category Category▶I▶according▶to▶UL/EN▶61010-1
Degree of pollution▶Degree▶2▶according▶to▶UL/EN▶61010-1
Protection rating according▶to▶IEC/EN▶60529
•▶ wall-mounted▶version •▶ IP65▶1),▶device▶wired,▶cable▶glands▶
tightened,▶cover▶lid▶screwed▶tight▶
and▶entry▶item▶nuts▶of▶the▶cable▶
glands▶tightened▶at▶a▶screwing▶
torque▶of▶1.5▶N·m▶
•▶ panel▶version •▶ front▶side▶IP65▶1),▶rear▶side▶IP20▶1)▶
1)▶not▶evaluated▶by▶UL
English

8
Technical data
Type 8025 UNIVERSAL
6.2 Conformity to standards and
directives
The▶applied▶standards,▶which▶verify▶conformity▶with▶the▶EU▶direc-
tives,▶can▶be▶found▶on▶the▶EU-type▶examination▶certificate▶and/or▶the▶
EU▶declaration▶of▶conformity▶(if▶applicable).▶
UL-Certification
Devices▶with▶variable▶key▶PU01▶or▶PU02▶are▶UL-certified▶devices▶
and▶comply▶also▶with▶the▶following▶standards:▶
•▶ UL▶61010-1▶
•▶ CAN/CSA-C22.2▶n°61010-1▶
Identification on▶the▶device Certification Variable key
▶UL-recognized▶ PU01▶
Measuring
Equipment
EXXXXXX
®
▶
UL-listed▶ PU02▶
6.3 Mechanical data
Part Material
Housing▶and▶cover,▶wall-mounted▶version▶ ABS▶
Cable▶glands,▶wall-mounted▶version▶ PA▶
Open▶housing,▶panel▶version▶ PC▶
Foil▶ polyester▶
4▶screws▶ Stainless▶steel▶
Cable▶clips▶ PA▶
6.4 Dimensions
▶→Please▶refer▶to▶the▶technical▶data▶sheets▶related▶to▶the▶device▶at:▶
www.burkert.com▶
6.5 Electrical data
Power supply 12...36 V DC •▶ filtered▶and▶regulated
•▶ max.▶tolerance▶12▶V▶DC:▶–5▶%▶
or▶+10▶%
•▶ max.▶tolerance▶36▶V▶DC:▶±10▶%
•▶ Connection▶to▶main▶supply:▶
permanent▶(through▶external▶
SELV▶(safety▶extra-low▶voltage)▶
and▶through▶LPS▶(limited▶power▶
source)
Power source (not▶supplied)▶ •▶ Limited▶power▶source▶according▶
to▶UL▶/▶EN▶60950-1▶standards
•▶ or▶limited▶energy▶circuit▶
according▶to▶UL▶/▶EN▶61010-1,▶
Paragraph▶9.4
115/230 V AC power supply
•▶ frequency▶ •▶ 50/60▶Hz▶
•▶ supplied▶voltage▶ •▶ 27▶V▶DC,▶regulated▶
•▶ maximum▶current▶ •▶ 250▶mA▶
•▶ integrated▶protection▶ •▶ 250▶mA▶time-delay▶fuse▶
•▶ power •▶ 6▶VA▶
English

9
Technical data
Type 8025 UNIVERSAL
Current consumption
(without▶the▶consumption▶of▶
the▶4...20▶mA▶output)
•▶ version▶without▶
relays,▶energized▶with▶
12...36▶V▶DC
•▶ version▶with▶relays,▶ener-
gized▶with▶12...36▶V▶DC
•▶ version▶without▶
relays,▶energized▶with▶
115/230▶V▶AC
•▶ version▶with▶relays,▶ener-
gized▶with▶115/230▶V▶AC
▶
▶
•▶ 50▶mA▶(at▶12▶V▶DC)▶▶
and▶30▶mA▶(at▶36▶V▶DC)▶▶
•▶ 70▶mA▶(at▶12▶V▶DC)▶▶
and▶45▶mA▶(at▶36▶V▶DC)▶
•▶ 35▶mA▶▶
▶
•▶ 50▶mA▶
Digital output DO1
(transistor)
•▶ type▶▶
•▶ function▶▶
•▶ frequency▶(f)▶
•▶ Electrical▶data▶▶
•▶ duty▶cycle▶if▶
0.6▶<▶f▶<▶300▶Hz▶
•▶ duty▶cycle▶if▶
300▶<▶f▶<▶1500▶Hz▶
•▶ duty▶cycle▶if▶
1500▶<▶f▶<▶2200▶Hz▶
•▶ protection▶
polarized,▶potential-free▶▶
•▶ NPN▶/▶PNP▶(wiring▶dependent),▶
open▶collector
•▶ pulse▶output▶(by▶default),▶user▶
configurable
•▶ 0.6...2200▶Hz
•▶ 5...36▶V▶DC,▶100▶mA▶max.,▶voltage▶
drop▶2.7▶V▶DC▶at▶100▶mA▶
•▶ >▶0.45▶▶
•▶ >▶0.4▶▶
•▶ <▶0.4▶▶
•▶ galvanically▶isolated,▶and▶
protected▶against▶over-
voltages,▶polarity▶reversals▶and▶
short-circuits▶
English

10
Technical data
Type 8025 UNIVERSAL
Digital outputs DO2 and
DO3 (relays)
•▶ operating▶▶
•▶ electrical▶data▶of▶the▶load▶
(non▶UL▶devices)▶
•▶ electrical▶data▶of▶the▶load▶
(UL▶devices)▶
▶
▶
•▶ max.▶breaking▶capacity▶
•▶ life▶span▶
▶
•▶ hysteresis▶(by▶default),▶user▶con-
figurable,▶normally▶open
•▶ 230▶V▶AC▶/▶3▶A▶▶
or▶40▶V▶DC▶/▶3▶A▶
•▶ max.▶30▶V▶AC▶and▶42▶Vpeak,▶3▶A▶▶
or▶max.▶60▶V▶DC,▶1▶A
To▶use▶the▶relay▶outputs▶in▶a▶wet▶
location,▶observe▶the▶following▶
DANGER▶safety▶instruction.
•▶ 750▶VA▶(resistive▶load)▶
•▶ min.▶100000▶cycles▶
Current output AO1
•▶ specification▶▶
▶
•▶ max.▶loop▶impedance▶
•▶ 4...20▶mA,▶sink▶or▶source▶(wiring▶
dependent),▶22▶mA▶to▶indicate▶a▶
fault▶(can▶be▶activated)
•▶ 1300W▶at▶36▶V▶DC,▶▶
1000W▶at▶30▶V▶DC,▶▶
750W▶at▶24▶V▶DC,▶▶
300W▶at▶15▶V▶DC,▶▶
200W▶at▶12▶V▶DC
•▶ 900W▶if▶the▶device▶is▶energized▶
with▶115/230▶V▶AC
DANger
Danger due to the operation of the relay outputs of a UL
device in a wet location.
▶▶If▶a▶UL▶device▶is▶used▶in▶a▶wet▶location:▶
▶- energize▶the▶relay▶outputs▶with▶an▶alternating▶voltage▶of▶max.▶
16▶Vrms▶and▶22.6▶Vpeak.▶
▶- or▶energize▶the▶relay▶outputs▶with▶a▶direct▶voltage▶of▶
max.▶35▶V▶DC.▶
6.6 Specifications of the connected
flow sensor
Signal originating from
the remote sensor
•▶ type▶▶
▶
▶
•▶ frequency
•▶ max.▶voltage
▶
•▶ pulse,▶sine-wave▶(typical▶sensitivity▶
50▶mV▶peak-to-peak▶at▶250▶Hz),▶
"on/off",▶or▶standard▶voltage▶
0...5▶V▶DC
•▶ 0.6▶Hz▶to▶2.2▶kHz,▶can▶be▶adjusted
•▶ 36▶V▶DC
Input impedance depends▶on▶the▶position▶of▶selector▶
"LOAD"▶on▶the▶electronic▶board▶of▶the▶
8025.▶See▶chap.▶7.4.11
English
Other manuals for 8025 UNIVERSAL
2
Table of contents
Popular Dispenser manuals by other brands

Silver King
Silver King Majestic SK12MAJ Technical manual and replacement parts list

Franke
Franke F3Dn Twin Service manual

STIEBEL ELTRON
STIEBEL ELTRON UltraHot Plus Operation and installation instructions

DAN DRYER
DAN DRYER 282 installation guide

Essity
Essity Tork 473208 manual

CBS
CBS SD300BU-88 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST