Your pump has been carefully packaged at the
factory to prevent damage during shipping. However,
occasional damage may occur due to rough handling.
Carefully inspect your pump for damages that could
cause failures. Report any damage to your carrier or
your point of purchase.
INSTALLATION
INSTRUCTIONS
MODEL
300526
EFFLUENT
PUMP
Please read these
instructions
carefully. Failure
to comply to
instructions and
designed
operation of
this system,
may void
the warranty.
© 2013 BUR-CAM Printed in Canada 310243

0DWHULDOUHTXLUHGIRUVXEPHUVLEOHHIÀXHQWSXPSLQVWDOODWLRQ:
Desired length of 1 1/2” or 1 1/4” ofABS/DWV pipe to link up the pump to the drain line.
1 only 1 1/4” check valve (350353) (Note that this 1 1/4” check valve may also be use with a
1 1/2” pipe).
18” x 25” sump basin.
1 1/4”-1 1/2” stainless steel clamps (750886).
ABS cement.
Tools:
6FUHZGULYHUVKDFNVDZWRFXWSLSHNQLIHWRDVVLVWLQSLSHFXWWLQJURXQG¿OHWRVPRRWKSLSH
HQGVSLSHZUHQFKDGMXVWDEOHZUHQFKWRWLJKWHQ¿WWLQJV
SAFETY INSTRUCTIONS:
7KLV¿QHSXPSWKDW\RXKDYHMXVWSXUFKDVHG
is designed from the latest in material
and workmanship. Before installation and
operation, we recommend the following
procedures:
Check with your local electrical and
plumbing codes to ensure you comply
with the regulations. These codes have
been designed with your safety in mind.
Be sure you comply with them.
Werecommendthataseparatecircuitbe
lead from the home electrical distribution
panel properly protected with a fuse or a
circuit breaker. We also recommend that
a ground fault circuit be used. Consult a
licensed electrician for all wiring.
The ground terminal on the three
prong plugs should never be removed.
They are supplied and designed for your
protection.
Never make adjustments to any
electrical appliance or product with the
power connected. Do not only unscrew
the fuse or trip the breaker, remove the
power plug from the receptacle.
Assuming that you have a sump
SLW ORFDWHG LQ \RXU EDVHPHQW ÀRRU
Your sump pit must be constructed from
concrete, brick, tile or more recently
a sump basin made from plastic
DQGRU ¿EHUJODVV 7KH PLQLPXP VL]H RI
your sump pit MUST be 18” in diameter
and no less than 25” deep. When pit is
ready, proceed to next step.
MONTHLY MANDATORY
CHECK-UP:
1. Inspect the pump and the sump for
any obvious condition that necessitates
cleaning, correction, adjustement or
repair.
2. Clear the sump and the surroundings
of any paper, leaves or other debris that
might clog the input openings. Remove
DQ\WKLQJWKDWPLJKWÀRDWLQWRWKHVXPS
3. Assure that the pump is secure and
vertical for proper operation.
4.Assure that there is adequate clearance
from any combustible materials or
structure. Stored materials must be kept
away from the pump. Shelves or cabinet
structures must not be in close proximity
over the pump.
5. Assure that the motor is securely plugged
into a proper ‘GFCI’ electrical outlet.
6. Test the ‘GFCI’ outlet by pressing its test
switch. This should prove that the outlet
LV HQHUJL]HG DQG ZLOO WULS RII WR SURWHFW
against a ground fault. Be sure to reset
the ‘GFCI’ by pressing its reset switch.
7./LIW WKH ÀRDW WR SURYH WKDW WKH SXPS ZLOO
start when required. (Step 8 below will
test submersible pumps with enclosed
ÀRDWV
8. Put a pail of water (8 liters) in the sump
to prove that any check valve present will
SHUPLWHIÀXHQWWRÀRZ
9. Observe that the plumbing can carry the
HIÀXHQWVDIHO\RXWRIWKHUHVLGHQFH
A
B
C
D
E
NOTICE
This unit is not designed for
applications involving salt water
or brine. Use with salt water or
brine will void warranty.

APPLICATION:
7KLVVXEPHUVLEOHHIÀXHQWSXPSLV
designed for a permanent installation for
domestic use homes, cottages and farms.
0XOWLSXUSRVHHIÀXHQWSXPSZLOO¿OOWKH
need in most sump applications.
To pump water as a permanent
installation pump.
Capacity: US GPH LPH
5’ 4400 16600
10’ 3600 13600
15’ 2700 10200
20’ 2000 7550
25’ 600 2250
FEATURES:
Cast iron pump housing.
Stainless steel motor body.
Noryl vortex impeller, clog free type.
Piggyback grounded cables.
+39$&+]$$DWVWDUW
INSTALLATION STEPS:
IMPORTANT NOTICE : Please note before you proceed with the installation of this
product that the manufacturer’s guideline has to be respected. Failure to comply may
void your warranty.
7KHIROORZLQJDUHPLQLPXPUHTXLUHPHQWVLQRUGHUWRSURWHFW\RXUUHVLGHQFHIURPÀRRGLQJ
It is a small investment but it is your personal responsibility to protect your home, family and
valuables. Failure to comply with the following requirements may also void your warranty:
7ZRSXPSVKDYHWREHLQVWDOOHGLQWKHVXPSSLW7KH¿UVWSXPSDVDSULPDU\SXPS
and the second pump as the backup unit.
- Burcam alarm system model 450454 has to be installed to advise you of any malfunctions.
$VVXPSSXPSVDUHHOHFWULFDOO\SRZHUHGDQGDFWLYDWHGVRWRSUHYHQWÀRRGLQJD%XUFDP
battery powered back up pump model 300403 has to be installed to evacuate the water.
Pump selection, proper and adequate installation are a must to comply with local
by-laws and need to be adhered to.
STEP 1 We recommand that you install your pump in a clean location where there
LV DGHTXDWH URRP IRU VHUYLFLQJ DW D ODWHU GDWH 3URWHFWLRQ IURP IUHH]LQJ
temperatures and good ventilation should be considered as well, to provide
the pump an environment for long life. Do not use to pump gas or toxic
fuels. This submersible sump pump is designed to pump water only.
Friction losses in the discharge pipe must be taken into consideration when
WKH KRUL]RQWDO RIIVHW LV JUHDWHU WKDQ IHHW 7KH GLVFKDUJH SLSH VKRXOG EH
increased from 1 1/2” to 2”. This will reduce friction losses and allow the
pump to give maximum performance. More friction losses must also be
WDNHQ LQWR FRQVLGHUDWLRQ ZKHQ PDQ\ HOERZV DQG ¿WWLQJV DUH LQVWDOOHG LQ WKH
GLVFKDUJHOLQH(DFKHOERZVDQG¿WWLQJVPXVWEHFRQVLGHUHGDVIHHWRIKHDG
7KH ÀRDW VZLWFK RI \RXU SXPS KDV EHHQ SUHVHW DW WKH IDFWRU\ DQG GRHV QRW
need any adjustment. Never run the pump dry. Damage to the seal may occur.
Fill pump pit or sump basin with water before turning on the power.
Friction loss
not included.

STEP 2 $VVXPLQJWKDW\RXKDYHDVXPSSLWORFDWHGLQ\RXUEDVHPHQWÀRRU<RXUVXPSSLW
may be constructed from concrete, brick, tile or more recently a sump basin made
IURPSODVWLFDQGRU¿EHUJODVV7KHPLQLPXPVL]HRI\RXUVXPSSLWVKRXOGEH´
in diameter and no less than 5” deep. When pit is ready, proceed to next step.
EFFLUENT PUMP APPLICATION
(See diagram on page 5)
STEP 3 At this step, you have the opportunity to install a 1 1/2” or a 1 1/4” discharge. We
recommend a 1 1/2” ABS/DWV discharge. Install a check valve (350362 in-line
1 1/2” or 350353 1 1/4” MNPT inlet and 1 1/4” or 1 1/2” outlet) over discharge
pipe of your pump and secure it with stainless steel clamps or glued nipple
for ABS/DWV pipe. This check valve will allow easy access to pump, should
service be required.
STEP 4 Install and position your submersible sump pump in the centre of your sump pit
RUEDVLQDQGHQVXUHWKDWWKHUHLVFOHDUDQFHWRDOORZWKHPHFKDQLFDOÀRDWVZLWFK
DIUHHZRUNLQJDUHDZLWKRXWREVWUXFWLRQVSLSHSLW¶VZDOOSRZHUFRUG7KHÀRDW
cord length is factory set and should not need adjustment. If adjustment is
required, the switch cord can be shorted or lengthed.
STEP 5 Install your discharge pipe from check valve to the point of discharge or drain.
)RULQVWDOODWLRQRYHUIHHWRIKRUL]RQWDOSRVLWLRQGLVFKDUJHSLSHXVHD´SLSH
to reduce friction loss.
STEP 6 Themechanicalswitchprovidedwithyourpumpissuppliedwithaserialelectrical
male plug. Fix the power cord of the pump into the piggy-back receptacle of the
switch and plug this one into electrical grounded outlet. We recommend that a
licensed electrician be employed to do wiring. Permanently ground the motor in
accordance to the electrical codes for your area. Do not use an extension cord
to connect your pump to the power source. From your distribution panel to the
receptacle, we recommend a wire gauge not smaller than 14 gauge. Use tape
RUWLHZUDSWR¿[SRZHUFRUGVWRGLVFKDUJHSLSH
STEP 7 Fill the sump pit or basin with water to test the operation of your submersible
sump pump. The motor should start when the water level reaches approximately
3” over your pump.Allow the pump to go through several “on-off” cycle to assure
satisfactory operation. If needed, see trouble shooting guide in this manual.
STEP 8 Review your installation with typical diagram. Check all connections for leaks.
MAINTENANCE:
Unplug the switch and pump motor power cord. Remove the pump from pit or basin.
5HPRYHWUDVKDFFXPXODWLRQDQGGLUWIURPWKHSXPSDQGÀRDWVZLWFK%HVXUHWKHÀRDW
switch operates freely after cleaning. If tar or paint has been received in the pit or basin,
XVHNHURVHQH WRUHPRYH UHVLGXHIURP ÀRDWVZLWFK RUSXPS Do not use strong paint
solvents.
Remove the screws that hold the strainer or the base to the bottom of the pump body. Pry
the base off the pump body carefully. Clean the impeller and volute passage way from
any debris wich may have become in contact with these parts. Again, If tar or paint has
entered pump, clean with kerosene. Do not use strong paint solvents. Be sure impeller
turns freely after cleaning.
Checkand clean away anydebriswichmay be clogging thesuctioninlet,pump discharge,
check valve and discharge line.
Replace screws and return sump pump to sump pit or basin and reconnect to piping.

EFFLUENT PUMP APPLICATION
REPAIR PARTS
REF. PARTS DESCRIPTION
1 310229 Top cover
2 310230 Motor
3 310231 Impeller
4 310232 Pump casing base
5 310233 Bottom plate
6 310234 Capacitor
7 310235 Mechanical seal
8 310236 Seal bracket
9 310237 Impeller key
10 310238 Pump casing O-ring
11 310239 Cover seal
12 310240 Pump casing seal
13 310241 Discharge adaptor
14 310242 Power cable
15 450447AG Vertical switch
16 310245 Switch bracket
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
STEP 3
Prepare your choice of
discharge pipe size
and check valve.
STEP 2
Sump pit 18’’ diameter
X 25’’ depth.
STEP 6
&RQQHFWÀRDWDQG
motor power cable.
STEP 4
Install your pump in
center of pît.
STEP 5
Install discharge pipe.
STEP 7
Fill the basin and test
the operation.
STEP 8
Review and check
connections for leaks.
5HSDLUSDUWVPD\EHRUGHUHGIURP\RXUDXWKRUL]HGSRLQWRIVDOHRUIURP
BUR-CAM PUMPS

TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE
POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE
THE POWER FROM THE RECEPTACLE.
TROUBLE PROBABLE CAUSE ACTION
Switch is off position
Blown fuse
Tripped breaker
Plug disconnected
Corroded plug
Low water level
Thermal overcharge
'HIHFWLYHVZLWFKÀRDW
Defective motor
,PSURSHUÀRDWSRVLWLRQ
Jammed impeller
Plugged check valve
Blocked suction/inlet
Discharge leak
Blocked line/pipe
Worn impeller
Defective motor
Defective switch
Float obstruction
Blocked suction/inlet
Turn switch to on position
Replace
Reset
Re-install
Clean prongs
Add water and verify
Cool the motor
Replace
Replace/repair
Check movement
Clean
Clean/replace
Check for debris in pit and clean
Repair
Check for debris or ice
Repair/replace
Replace
Replace
Adjust/check
Check for debris in pit and clean
Motor does not
run.
Pump does not
deliver to full
capacity.
Pump does not
shut off.
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415, and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
Table of contents
Other Burcam Water Pump manuals

Burcam
Burcam 400505TW User manual

Burcam
Burcam 506121S User manual

Burcam
Burcam 300735 User manual

Burcam
Burcam 300514W User manual

Burcam
Burcam 503121S User manual

Burcam
Burcam 300910 User manual

Burcam
Burcam 101124 User manual

Burcam
Burcam 506518SS User manual

Burcam
Burcam 400505H User manual

Burcam
Burcam 300527 User manual
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual