Braebon Ultima 0580A User manual

8OWLPD'XDO$LUIORZ
3UHVVXUH6HQVRU.LW
0RGHO$'
8VHU*XLGH
Pour une traduction française de ce guide
d'utilisateur, allez à www.braebon.com
Per una traduzione italiana di questa
guida dell'utente, vada a
www.braebon.com
Für eine deutsche Übersetzung dieses
Benutzerführers, gehen Sie zu
www.braebon.com
Para una traducción española de esta
guía del usuario, vaya a
www.braebon.com
$
%UDHERQ0HGLFDO&RUSRUDWLRQ
3URGXFW

7DEOHRI&RQWHQWV
7DEOHRI&RQWHQWV
,QWHQGHG8VH
6DIHW\,QIRUPDWLRQ
6DIHW\&RQYHQWLRQV
:DUQLQ V
&DXWLRQV
)HDWXUHVRIWKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
'XDO$LUIORZ3UHVVXUH6HQVRU.LW$'&RQWHQWV
$ERXWWKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
,QSXWV
2XWSXWV
*DLQDQG%DVHOLQH$GMXVWPHQW6FUHZV
%DWWHU\6WDWXV,QGLFDWRU/('
&RQQHFWLQ WKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
STEP 1: &RQQHFWWKHSUHVVXUHVHQVRUWR\RXUVOHHSUHFRUGLQ V\VWHP
STEP 2: &RQQHFWWKHVDIHW\ILOWHURQWKHFDQQXODWRWKHSUHVVXUHVHQVRULQSXWV
STEP 3: 3RVLWLRQWKHFDQQXODRQWKHSDWLHQW
STEP 4: $GMXVWWKH DLQLIQHFHVVDU\
&DOLEUDWLQ WKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
0DLQWDLQLQ WKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
5HSODFLQ WKH%DWWHU\
7URXEOHVKRRWLQ
3URGXFW6SHFLILFDWLRQV
:DUUDQW\

,QWHQGHG8VH
QWHQGHG8VH
The Ultima Dual Airflow Pressure Sensor™ is intended for use during sleep disorder studies as a
measure of respiratory airflow for recording onto a data acquisition system.
The Ultima Dual Airflow Pressure Sensor™ is a battery-powered pressure transducer that uses
state-of-the-art-miniaturized technology to detect and reproduce waveforms associated with
respiratory airflow from both the nose and mouth. Respiratory pressures are converted into
voltage signals compatible with a variety of data acquisition systems.
The differential pressure system uses either custom Braebon™ cannulas (Model 0589, 0588,
0582s, or others) or standard oxygen (O2) cannulas with the Braebon™ safety filter. The single-
use nasal cannula has a 0.2-micron hydrophobic filter that prevents the spread of contaminants
between patients and prevents moisture damage to the pressure sensor. The cannula attaches to
the positive input of the Ultima Dual Airflow Pressure Sensor™.
The pressure sensor essentially functions as an uncalibrated pneumotachograph. The sensor
detects and amplifies pressure swings from the cannula using a stable pressure transducer
capable of detecting differential pressures in the ±25 cm H2O range. The corresponding voltage is
then output for data acquisition.

6DIHW\,QIRUPDWLRQ
6DIHW\ QIRUPDWLRQ
For your personal safety, please read the safety conventions and the warnings and cautions in this
manual.
6DIHW\&RQYHQWLRQV
These are the safety conventions for this manual. The table below lists the safety symbol, the
name for the symbol, and the meaning of the symbol.
Warning
The Warning message appears in the manual before
procedures or tasks that must be strictly observed to avoid
patient injury or harm.
Caution
The Caution message appears in the manual before
procedures or tasks that must be strictly observed to avoid
damage to the product.
Note The Note message contains important information to help
the operator complete a procedure or task correctly.

6DIHW\,QIRUPDWLRQ
• The Ultima Dual Airflow Pressure Sensor™ is for diagnostic use only; it is NOT intended as an
apnea monitor, and it is NOT to be used in life sustaining situations.
• U.S. Federal law restricts this device to sale by or on the order of a physician.
• Always use a new single-use Ultima Airflow Pressure Cannula (Model 0589, 0588, 0582s, or
others) and a new Braebon™ safety filter (Model 0583) with each patient. The Braebon™
safety filter is required to prevent the spread of contaminants between patients and to prevent
moisture damage to the pressure sensor. Failure to use the Braebon™ safety filter will void the
warranty.
• To prevent dust contamination to the pressure sensor always keep safety filters attached to
the unit and change the safety filters immediately prior to next patient use.
• Use only isopropyl alcohol pads to clean the pressure sensor.
•DoNOT immerse the pressure sensor (Model 0585) in any liquids.
•DoNOT steam autoclave or gas sterilize the pressure sensor or damage will result.
• Use two 1.5V AA batteries or damage to the Ultima Dual Airflow Pressure Sensor™ will result.
Do NOT mix battery types. Do NOT insert the batteries backwards.
• If mounting the pressure sensor on the wall, mount the unit upside down to minimize the
likelihood of bending or kinking the cannula tubing.
:DUQLQJV
&DXWLRQV

)HDWXUHVRIWKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
)HDWXUHVRIWKH8OWLPD'XDO$LUIORZ
3UHVVXUH6HQVRU
• Six Outputs
• Three Inputs
• Gain and Baseline Adjustment
•ON/OFFSwitch Auto-Off (after 10 hours run-time)
• Battery Powered 2 AA Alkaline Batteries
• Nasal Airflow &
Snoring Output
Pure or raw nasal airflow pressure with superimposed snoring
signal
• Nasal Airflow Output Filtered nasal airflow pressure with no snoring signal
• Nasal Snoring
Output
Snoring signal from upper airway pressure vibrations
• Oral Airflow &
Snoring Output
Pure or raw oral airflow pressure with superimposed snoring
signal
• Oral Airflow Output Filtered oral airflow pressure with no snoring signal
• Oral Snoring Output Snoring signal from upper airway pressure vibrations
• Nasal Input Facilitates combining nasal and oral breathing on one channel
by connecting a Braebon™ Ultima Oral/Nasal Cannula (Model
0589) to the nasal input only
Facilitates recording nasal breathing only using any nasal
cannula with a Braebon™ Safety Filter (Model 0583) connected
to the nasal input only
• Differential Nasal
Input
Facilitates connection to a CPAP circuit
• Oral Input Facilitates recording nasal and oral breathing on separate
channels by connecting a Braebon™ Ultima Oral & Nasal Dual
Lumen Cannula (Model 0588) to both the oral and nasal inputs
• Battery Status
Indicator LED
Blinks green every 10 seconds to indicate the batteries are OK
Blinks red every two seconds to indicate the batteries are low

'XDO$LUIORZ3UHVVXUH6HQVRU.LW$'&RQWHQWV
'XDO$LUIORZ3UHVVXUH6HQVRU.LW
$'&RQWHQWV
The 0580A and 0580D Dual Airflow Pressure Sensor kits include the following items:
• One Ultima Dual Airflow Pressure Sensor™ (Model 0585)
• One adult dual lumen nasal & oral cannula with hydrophobic filter (Model 0588)
• One adult nasal/oral cannula with hydrophobic filter (Model 0589)
• Two adult nasal micro cannulas with hydrophobic filter (Model 0582s)
• One AC Interface Cable (Model 0592)
• One DC Interface Cable (Model 0594)
• Two 1.5 volt AA alkaline batteries (installed when shipped from the factory)
• One User Guide
In addition to the items mentioned above, the 0580A Dual Airflow Pressure Sensor Kit for Alice
includes the following:
• Two Alice Interfaces for the 0585 Dual Pressure Sensor (Model 0586A)
• Two Alice Interface Cables (Model 0593)

$ERXWWKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
$ERXWWKH8OWLPD'XDO$LUIORZ
3UHVVXUH6HQVRU
The Ultima Dual Airflow Pressure Sensor™ is a differential pressure transducer that detects and
amplifies pressure swings in the cm of H2O range. The voltage corresponding to the
differential pressure is output for data acquisition.
The Ultima Dual Airflow Pressure Sensor™ has three inputs and six outputs with an output range
of volts. With the Ultima Dual Airflow Pressure Sensor™, you can adjust the gain and baseline
controls for both the nasal and oral output channels. The output range will vary according to the
gain and baseline settings you used during recording.
Figure 1 The Ultima Dual Airflow Pressure Sensor™
25
±
5±
Nasal Cannula Input
Oral Cannula Input
Nasal
Differential
Input (CPAP
connection)
Battery Status Indicator LED
ON/OFF Switch
Nasal Airflow &
Snoring Output
Nasal Airflow Output
Nasal Snoring Output
Oral Airflow &
Snoring Output
Oral Airflow Output
Oral Snoring Output
Nasal Gain
Nasal Baseline
Oral Gain
Oral Baseline

$ERXWWKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
QSXWV
The Ultima Dual Airflow Pressure Sensor™ has three inputs: nasal input, nasal differential input
(CPAP connection), and oral input.
Nasal Input
With the nasal input, you can either combine oral and nasal breathing into one channel using
a single lumen, oral/nasal cannula connected to the nasal input or you can record nasal
breathing only using any nasal cannula connected to the nasal input.
Nasal Differential Input
With the nasal differential input, you can subtract a known pressure from the nasal baseline by
connecting your CPAP circuit to the nasal differential input.
The nasal differential input is your baseline for the nasal input. If you do not connect anything,
then you are using atmospheric pressure as your baseline for your nasal input. However, if
you attach a CPAP circuit to the nasal differential input, then you are using the CPAP pressure
as the baseline instead of atmospheric pressure.
Oral Input
With the oral input, you can record oral and nasal breathing on separate channels using a
dual lumen, oral and nasal cannula connected to both the oral and nasal input.

$ERXWWKH8OWLPD'XDO$LUIORZ3UHVVXUH6HQVRU
2XWSXWV
On the left side of the Ultima Dual Airflow Pressure Sensor™, there are six outputs — three nasal
outputs and three oral outputs. See Table 1 Output Types. You may choose to record from one to
six outputs from the Ultima Dual Airflow Pressure Sensor™.
Table 1 Output Types
Output Name Signal Type Example of Signal
• Nasal Airflow
& Snoring
Output
Pure or raw nasal airflow pressure with
superimposed snoring signal
• Nasal Airflow
Output
Filtered nasal airflow pressure with no
snoring signal
• Nasal Snoring
Output
Snoring signal from upper airway
pressure vibrations
• Oral Airflow &
Snoring
Output
Pure or raw oral airflow pressure with
superimposed snoring signal
•OralAirflow
Output
Filtered oral airflow pressure with no
snoring signal
• Oral Snoring
Output
Snoring signal from upper airway
pressure vibrations
Nasal Airflow and Snoring (Unfiltered)
Nasal Airflow (Snoring Filtered Out)
Nasal Snoring (Airflow Filtered Out)
Oral Airflow and Snoring (Unfiltered)
Oral Airflow (Snoring Filtered Out)
Oral Snoring (Airflow Filtered Out)
This manual suits for next models