Bpt TH 345 User manual

PROGRAMMABLE
THERMOSTAT
THERMOPROGRAM
PROGRAMMIERBARER
RAUMTHERMOSTAT
THERMOPROGRAM
THERMOSTAT
PROGRAMMABLE
THERMOPROGRAM
D
GB
F
1234567
T3
T2
T1
048121620
ON
GBDF
INSTRUCTIONS
FOR USE
GEBRAUCHS-
ANWEISUNG
MODE
D’EMPLOI
TH345
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 1

2GB
Congratulations on your purchase
of the TH345 thermostat.
To get the best performance and
make the best use of the features
and functions of your thermostat,
read this handbook with care and
keep it available for consultation.
RECOMMENDATIONS
FOR THE INSTALLER
• Read the contents of the follo-
wing pages with care because they
provide important information and
advice concerning the safe use,
installation and maintenance of the
thermostat.
• When you remove the packaging,
make sure that the thermostat is in
good order.
• The plant must be in compliance
with current safety standards.
• The manufacturer cannot be held
liable for any damage due to
improper, erroneous or unreaso-
nable use of the device.
• For any repairs, only call in an
aftersales service authorized by the
manufacturer.
• Failure to comply with the above
recommendations may prejudice
the safety of the device.
DISPOSAL
Do not litter the environment with
packing material: make sure it is
disposed of according to the regu-
lations in force in the country
where the product is used.
When the equipment reaches the
end of its life cycle, take measures
to ensure it is not discarded in the
environment.
The equipment must be disposed
of in compliance with the regula-
tions in force, recycling its compo-
nent parts wherever possible.
Components that qualify as recy-
clable waste feature the relevant
symbol and the material’s abbrevi-
ation.
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 2

GB 3
T3
T2
T1
ON
048121620
LU MA ME GI VE SA DO
The TH345 thermostat compri-
ses:
No. 1 BPT front plate
No. 1 thermostat body
No. 1 adapter for the VIMAR idea
range of front plate
No. 1 adapter for front plate
AVE (system 45)
No. 1 hole plug
No. 1 chassis with 2 screws for
fixing the chassis to the embed-
ding box
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 3

4GB
121110981476
4
3
2
1
13 18
16
15
17
T3
T2
T1
048121620
1234567ON
5
1234567ON
Fig. 1
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 4

KEY TO SYMBOLS AND
OUTSIDE CONTROLS,figure 1
SYMBOLS
10 ÷ 23 Time scale in the pro-
gram graph.
Flashing of the cursor
indicates the hour
coinciding with the
time on the clock.
2T1÷T3 Temperature levels.
3 Digital thermometer.
4 Digital clock.
5 The appearance of this
message indicated that
the batteries are flat.
6 Day of the week.
7 Stand-by mode.
8 WILD CARD program.
9 COOLING program.
1÷7
10 HEATING program.
11 Antifreeze function.
12 Thermostat enabled.
13 Time bands when the
heating/cooling plant
operates.
Red = comfort.
Blue=energy saving.
CONTROLS
14 Selects MANUAL or
AUTOMATIC thermo-
stat mode.
15 Up/Forwards (tempe-
rature, day, hour, etc.).
16 Down/Backwards (tem-
perature, day, hour,
etc.).
17 Multi-function.
ON
18 Disable thermostat
control of the plant.
INSIDE
CONTROLS
To access these inside controls,
draw the tab L and the thermostat
body out of the housing until it
stops, as illustrated in the sequen-
ce in figure 2.
19RReset button.
20 Clock setting.
21TProgramming the tem-
perature levels (T1 to
T3). Programming the
temperature threshold.
Viewing the temperatu-
re levels.
22 Selection the COOLING
program ( ) or the
HEATING program ( ).
GB 5
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 5

6GB
12
3
T3
T2
T1
ON
048121620
LU MA ME GI VE SA DO
T3
T2
T1
ON
04812
16 20
LU MA ME GI VE SA DO
L
023T
19 20 21 22 23 24 25 26
C
R17
Fig. 2
23 0÷23Moves the time in the
daily program graph
backwards.
240÷23 Moves the time in the
daily program graph
forwards.
251÷7 Selection the day of the
week.
26CCopy program.
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 6

GB 7
the various times of the day and
week.
The THERMOPROGRAM is extre-
mely easy to program, even before
it is installed; a spacious display
facilitates this operation, since you
can “see” and change all the infor-
mation and program setting at any
time.
The temperature threshold can be
set at valves between ±0.1 °C and
±0.9 °C.
The THERMOPROGRAM can
generally control both heating and
cooling plants and it can replace
any previous on/off thermostat.
THERMOPROGRAM
TH345
The THERMOPROGRAM pro-
grammable thermostat is designed
to ensure ideal temperature condi-
tions at all hours of the day and
every day of the week.
Its installation calls for the use of a
three-module flush-mounted junc-
tion box and it can be connected to
the heating/cooling plant simply by
means of two wires.
Three LR03 type AAA 1.5 V alkali-
ne batteries are used to power the
THERMOPROGRAM for over a
year.
Once it has been installed, it is
immediately ready to operate with
its permanently-memorized stan-
dard program.
To suit individual needs, the pro-
gram can be adjusted at will, set-
ting the required temperatures for
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 7

8GB
CONTENTS
Chapter Page
1 - Installation 9
2 - Electric connections 11
3 - Setting the clock 13
4 - Standard programs
in permanent memory 14
5 - Manual operation 15
6 - Personalizing temperature
level values for
the heating program 17
7 - Personalizing temperature
level values for
the cooling program 18
8 - Personalizing the daily
temperature program 18
9 - WILD CARD program 20
10- Antifreeze function 22
11- Plant running time 24
12- Viewing the temperature
level values 24
13- Stand-by mode 25
14- Reset 27
15- Temperature threshold 28
16- Replacing the batteries 28
17- Technical features 30
- Genaral guarantee terms 31
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 8

GB 9
T3
T2
T1
0
4
812 16 20
LU MA M
Fig. 6
T3
T2
T1
ON
048121620
LU MA ME GI VE SA DO
1
L
2
T3
T2
T1
ON
048121620
LU MA ME GI VE SA DO
3
4
3
Fig. 4
Fig. 5
T3
T2
T1
0481216
20
LU MA ME GI VE SA DO
Fig. 3
1 - INSTALLATION
Install the thermostat in a position
where it can detect the average
room temperature (avoid placing
the thermostat inside recesses,
behind door or curtains, or near
radiators).
THERMOPROGRAM is installed
flush mounted in a three-module
box (50 mm deep), proceeding as
follows:
• Remove the front plate from the
housing, figure 3.
• Draw the tab L and the thermo-
stat body out of the housing until it
stops, figure 4, then press gently
on the two side flaps coinciding
with the symbol, figure 5,
detach it completely from the box.
• Insert three LR03 type AAA 1.5 V
alkaline batteries, following the
polarity indications on the bottom
of the housing, figure 6.
WARNING. Inserting the batteries
the wrong way round can damage
the thermostat.
If the messages on the display do
not appear within 30 seconds,
press the reset button R (fig. 71).
Once the above steps have been
taken correctly, the display shows
T3
T2
T1
048121620
1234567 ON
Fig. 7
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 9

10 GB
the indications illustrated in figure 7.
• Make the electric connections to
the terminal block of the housing
as illustrated in the diagrams in
figure 12A or 12B.
• Fix the housing to the flush-moun-
ted junction box by means of the two
screws provided, figure 8, making
sure that it is the right way up.
•Push the thermostat body fully
into the housing and attach the
front panel.
Insert the tab L.
NOTE. The thermostat is supplied
with three adapters to allow for
Fig. 8
T3
T2
T1
ON
04812 16 20
LU MA ME GI VE SA DO
BODY BPT
FRONT PLATE
BTICINO
(Art. L4803)
(Art. N4803)
VIMAR
(Serie Plana
art. 14653)
CHASSIS
3-MODULES
EMBEDDING
BOX
Fig. 9
TH345.01 ITF 24078822 04_06 11-07-2007 8:21 Pagina 10
Table of contents
Languages:
Other Bpt Thermostat manuals
Popular Thermostat manuals by other brands

Saswell
Saswell SAS920XWHB-7-S-RF User manual and warranty card

Aircalo
Aircalo TFP1-ET85P2 operating manual

Honeywell
Honeywell CM721 user manual

Carrier
Carrier DEBONAIR 33CS Installation and operating instructions

Lennox
Lennox iHarmony Zone Thermostat Installation and setup guide

Gemtech