Page 2
TABLE OF CONTENTS
1.....Introduction.. ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... .......2
2.....Specifications ............... ............... ............... ............... ............... ...............3
3.....Features......... ............... ............... ............... ............... ............... ...............3
4.....Unpacking..... ............... ............... ............... ............... ............... ...............3
5.....Installation.... ............... ............... ............... ............... ............... ...............4
5.1 ..Mounting location.. ............... ............... ............... ............... ...............4
5.2 ..Input power connections (A-100NVP) .. ............... ............... ...............5
5.2.1 ..External input/output signal connections (A-100NVP) .... ...............6
5.3 ..Input power connections (A-100NFP)... ............... ............... ...............8
5.3.1..Optional output signal connection (A-100NFP) ............... ...............10
5.4 ..How to install the tubing and fittings .... ............... ............... ...............12
6.....How to operate the A-100N Polymer Pump .............. ............... ...............13
6.1 ..Description of Pump Output Adj. Controls (A-100NVP)...... ...............13
6.1.1..Mode 1 - Manually Adjusting the output........... ............... ...............14
6.1.2..Mode 2 - 4-20 mA input .... ............... ............... ............... ...............15
6.1.3..Mode 3 - 0-10 VDC input. ............... ............... ............... ...............16
6.1.4..Mode 4 - Frequency/Pulse (Hz) input ............... ............... ...............18
6.2 ..How to adjust the output (A-100NFP)... ............... ............... ...............20
7.....Alarms........... ............... ............... ............... ............... ............... ...............21
7.1 ..TFD+ - Enhanced Tube Failure Detection system. ............... ...............21
7.2 ..FVS - Flow verification System ............ ............... ............... ...............22
8.....How to maintain the pump ......... ............... ............... ............... ...............23
8.1 ..Routine inspection and cleaning ............ ............... ............... ...............23
8.2 ..How to clean and lubricate the Pump .... ............... ............... ...............23
8.3 ..500 hour service warning timer ............. ............... ............... ...............23
8.4 ..How to replace the pump tube ............... ............... ............... ...............24
Replacement pump tube part numbers ..... ............... ............... ...............25
Replacement parts drawing (A-100NVP) .. ............... ............... ...............26
Replacement parts list (A-100NVP) ........... ............... ............... ...............27
Replacement part drawing (A-100NFP) .... ............... ............... ...............28
Replacement parts list (A-100NFP)............ ............... ............... ...............29
Warranty information . ............... ............... ............... ............... ...............30
1.0 Introduction
Congratulations on purchasing the A-100N Polymer Peristaltic Metering
Pump. The A-100N Polymer Pump is designed to inject polymers and
compatible fluid solutions into piping systems. The A-100N Polymer Pump
is equipped with external input control circuitry which allows the pumps
output to be externally controlled by either a 4-20mA input signal, a 0-10V
DC input signal or a pulsed frequency input signal.
A-100N Page 3
2.0 Specifications
Maximum Working Pressure 65 psig / 4.5 bar (most models)
o o
Maximum Fluid Temperature 130 F / 54 C
o o
Ambient Temperature Range 14 to 110 F / -10 to 43 C
Duty Cycle Continuous
Adjustment Range
14 & 30 RPM with -1T, -2T tubes 5-100% of speed (20:1 turndown)
All other models 10-100% (10:1 turndown)
Maximum Solids 50% by volume
Maximum Viscosity 5,000 Centipoise
Maximum Suction Lift up to 30 ft. water
Power Requirements 108/130Vac 60Hz 40 Watts,
208/250Vac 40Hz 40 Watts,
208/250Vac 60Hz 45 Watts
Dimensions 6-1/8” H x 10-1/8” W x 9” D
Weight
A-100NVP 12 lb. (5.4 kg.)
A-100NFP 8 lb. (3.6 kg.)
3.0 Features
!Peristaltic Pump Tube does not require valves.
!Self priming under maximum pressure. Cannot vapor lock.
!High outlet pressure capability of 100 psig (most models).
!High inlet suction lift capability of 30 feet.
!Enhanced Tube Failure Detection (TFD+) system.
!Patented pump tube assembly design.
!Includes Flow Verification System (FVS) - sensor sold separately.
!1 amp alarm relay (dry contact).
!Alarm and Service alert icon displays.
!Corrosion proof Valox housing.
!Tamper resistant electronic control panel cover.
4.0 Unpacking
Your pump package should contain the following:
1 - Injector pump with 2 pump tube assemblies
1 - suction tube strainer
1 - ceramic tubing weight
1 - 5’ Length of clear PVC suction tubing
1 - 5’ Length of opaque LLDPE discharge tubing
1 - Injection fitting with internal back-flow check valve
1 - Mounting hardware kit
1 - Shroud (weather proof cover see page 16)