BATHSELECT BS145009N User manual

Plumbers Tape Tape Measure Adjustable Wrench
Screwdriver
Drill
Hex Wrench
Level
Pencil or Marker
Thread Sealant
*not included
POSSIBLE TOOLS REQUIRED*
Please read installation instructions below. All plumbing should be
installed in accordance with applicable building codes and regulations.
Unpack and inspect the items for any shipping damages. If you find
damages, do not install.
All products must be installed by a professional and certified plumber
otherwise warranty may be voided.
PRIOR TO INSTALLATION
22" LED WALL MOUNT WATERFALL RAINFALL SHOWER SYSTEM
WITH HANDHELD SHOWER INSTALLATION INSTRUCTIONS
Customer Service: 800-500-9895
bathselect.com
Product code: BS145009N

Open the top cover and drill according to the
marked position.
1. Mark by the position of the four holes.
2. Take care to avoid wires and pipes to prevent
damage.
3. Be sure to confirm that the four holes are on the
same horizontal line.
Two inlet fittings are connected to the pipe joint
of the wall; then the nut, expansion screw, and
inlet pipe are connected.
Reinstall the top cover.
Shower Head Installation Instructions
Step 1:
Step 3:
Step 2:
Product shown is only for installation display purpose
(If you have opted for LED option)
The LED light will change its color by detecting
water temperature:
0-30°C (32-86°F): Blue LED
30-40°C (86-104°F): Green LED
40-50°C (104-122°F): Red LED
50-100°C (122-212°F): Flashing Red LED
Note: The LED lights are powered by water flow,
and will be activated once the water is turned on.
Customer Service: 800-500-9895
bathselect.com

Hand Shower Installations Instruction
0.19” (4.8mm) Max
1
2
1
1. SUPPLY ELBOW INSTALLATION
Apply plumber tape to threaded ends of 1/2" (13 mm)
iron pipe nipple (not supplied) and thread into
shower riser elbow so that nipple extends past the
finished wall no more than 0.19" (4.8 mm) and no less
than 1/16" (1.6 mm). Place the supplied installation
gasket (1) behind the elbow (2). Screw the supply
elbow onto the nipple making sure that the supply
elbow outlet is in a downward facing position.
Minimum diameter for hole is 1" (25 mm) with a
maximum of 1 1/2" (38 mm).
CAUTION: To avoid damage to the supply elbow or
hose finish during installation, wrap with a cloth or
tape and use only a smooth-jawed wrench.
DO NOT OVERTIGHTEN CONNECTIONS.
3. WALL BAR INSTALLATION
Note: Hole size will be determined by your use of just the screw or
anchor and screw for installation. Drill hole for mounting of bottom
post. Start with a smaller drill bit size, 1/8" is recommended, and drill
hole. If you hit a wall stud, go to next step. If you do not hit a wall stud,
change to a drill bit size suitable for the anchors, 1/4" is recommended,
and re-drill hole.
Anchors are for use on drywall or tile. For fiberglass, acrylic and flat
plastic surfaces, use toggle bolts (not included).
Before drilling top mounting hole, it is recommended that you place
the assembled slide bar and post assembly (1) on its side next to the
hole locations you have marked. Make sure posts are pressed fully onto
bar. Align center of bottom post with bottom hole that was just drilled
and make sure center of top post aligns with mark for top hole. If not,
re-mark top hole location. If it aligns, drill top hole in location as
marked.
2. Mark the place for drilling the hole for the lower
post. Mark using a level, in a vertical line from the
lower hole, the placement of the upper post hole.
Distance approximately 25.7" (653 mm).
Step 1: Step 2:
Step 3:
Customer Service: 800-500-9895
bathselect.com

1
2
3
4
1
6
2
3
4
5
6
7
8
9
1
2
3
4
5. Slide the slide mechanism (1) and elbow (2)
onto the wall bar (3). Slide wall bar over bracket
tabs (4) and secure the wall bar unit with screws
(5) provided. Install caps (6) into ends of wallbar.
Lower elbow (7) & screw (8) was pre-installed
prior to shipping, tighten screw (9) if you find it
is sliding inside bar.
6. INSTALLATION OF THE SHOWER SET
Connect the shower hose to the wall outlet (1)
and the hand held piece (2), ensuring that the
internal gaskets (3) are present in the shower
hose nuts. Normal 1/2” rubber gaskets can be
used.
Place the conical nut of the hose (4) that is
connected to the hand held piece, in the slide
bar holder (5) and turn it to desired position.
To slide the mechanism up or down, push in on
the button (6) of the mechanism and slide it on
the bar.
4. Insert anchors (1) into drilled holes. Slide
covers (2) over brackets (3), and insert screws (4)
into bracket/cover assembly. Secure assembly
to wall with screws.
Step 4:
Step 5: Step 6: Completed
Customer Service: 800-500-9895
bathselect.com

Mixer Installations Instructions
Step 1 Step 2
Step 3 Step 4
Step 6
Step 5
Function 1
Function 2 Function 3
Customer Service: 800-500-9895
bathselect.com

Step 8Step 7
• According to the basic picture of the product, refer to the above picture, open the wall
to dig the main body embedded port, the hot and cold water inlet, and the mixed water
outlet.
• Drill5 6mm(0.2") holes with impact drill according to product size.
• Use a hammer to break four expanded capsules into the drilled holes.
• Connect each takeover, then connect the water source to confirm that there is no
leakage.
• Adjust the embedded body to the horizontal line, and fix the embedded body on the
wall with a cross screwdriver to lock the 4 self- tapping screws. Seal the pipeline with
cement filler.
• Loosen the two M5 screws on the sheath counter-clockwise with a cross screwdriver
and remove the sheath.
First, remove the color button of the constant temperature handwheel, loosen the main
handwheel in the counterclockwise direction with the 2.5mm hex plate, and remove it.
When taking out the constant temperature handwheel, do not turn the constant tem-
perature handwheel to ensure that the constant temperature handwheel button is
aligned with the 38-degree dial line on the panel.
• Tighten the three long poles on the key-value core, flatten the wall on the set, and cut
off the extra parts with a cutting machine or blade to extend the positioning plate plane
of the long rod. Then go to the positioning board and press the icon.
Positioning board
Long pole
The excess part of the long bar.
Tight on the wall.
• Balance the panel on the main body. Put the accessories of the constant temperature
handwheel in the opposite direction of the unloading on the main body,(pay attention
to the constant temperature handwheel installation to ensure that the valve core does
not turn, the button direction is aligned with the direction of the outlet pipe.)
(8a) (8b)
(8c)
Customer Service: 800-500-9895
bathselect.com
7
3

1. The product can be cleaned with warm water, a mild soap and a clean soft cloth.
2. Clean progressively and gently.
3. It is not required to use any abrasive cleaning pads, wire wool or cloths to clean the
product.
4. Avoid a vigorous cleaning action, as this could contribute to denaturing and dulling
5. Abrasive or strong cleaning products containing ammonia, bleaches, alcohol, dyes,
acids (hydrochloric, formic, phosphorus, chlorine or acetic) will be not be affected.
6. If using a spray cleaner, apply the cleaning agent onto a soft cloth, never directly spray
onto the product as the cleaner may enter gaps and openings and cause damage. Do
not allow the cleaner to remain on the product for a period of time. After cleaning, rinse
thoroughly with clean water.
Acid
General Information
Care & Cleaning
Customer Service: 800-500-9895
bathselect.com
All products manufactured and supplied by BathSelect are safe and comply to legislative
requirements. Providing they are installed correctly and receive regular maintenance in
accordance with these instructions your user experience will not be affected.
Table of contents
Other BATHSELECT Bathroom Fixture manuals