Banner TCNM-AD User manual

Quick Start Guide
General View
1
2
56
7
4
3
1 = Laser Beam Output Window
2 = POWER ON LED
3 = Warning and Device Class Labels
4 = Accessory Mounting Holes
5 = Mounting Holes
6 = LEDs
7 = Push Button
NOTE:
The Quick Start Guide describes stand-alone application. For other types of installations, such as ID-
NET™, Pass-Through, Multiplexer Layout, etc. and for a complete scanner configuration using
GeniusPlus configuration program, refer to the TCNM-AD/EX Manual.
STEP 1 – Connect the System
NOTE: This section illustrates a standalone application. For a pass-through installation, refer to the
appropriate section. For complete scanner configuration using the GeniusPlus configuration program,
refer to the Context-Sensitive Help On-Line.
To connect the system in a standalone configuration, you need the hardware indicated below. In this layout, the data is
transmitted to the Host on the main serial interface.
• In Local Echo communication mode, data is transmitted on the RS-232 auxiliary interface independently from the
main interface selection.
• When On Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when
the object enters its reading zone.
TCNM-AD Barcode Scanner
P/N 175718 Rev. A 29 January 2014
0 175718 7

Barcode
Scanner
Host
Trigger
* Presence Sensor
(for On-Line mode)
MAIN
I/O, AUX
TCNM-ACBB1
Figure 1. Barcode scanner in a standalone layout
TCNM-ACBB1 Pinout
The table below gives the pinout of the TCNM-ACBB1 terminal block connectors. Use this pinout when the barcode scanner
is connected using the TCNM-ACBB1:
TCNM-ACBB1 Terminal Block Connectors
Input Power Outputs
Vdc Power Supply Input Voltage + +V Power Source - Outputs
GND Power Supply Input Voltage – –V Power Reference - Outputs
Earth Protection Earth Ground O1+ Output 1 +
O1– Output 1 –
Inputs O2+ Output 2 +
+V Power Source – External Trigger O2- Output 2 –
I1A External Trigger A (polarity
insensitive) Auxiliary Interface
I1B External Trigger B (polarity
insensitive) TX Auxiliary Interface TX
–V Power Reference – External Trigger RX Auxiliary Interface RX
+V Power Source – Inputs SGND Auxiliary Interface Reference
I2A Input 2 A (polarity insensitive) ID-NET™
I2B Input 2 B (polarity insensitive) REF Network Reference
–V Power Reference – Inputs ID+ ID-NET™network +
Shield ID– ID-NET™network –
Shield Network Cable Shield
Main Interface
RS232 RS485 Full-
Duplex RS485 Half-Duplex
TX TX+ RTX+
RTS TX– RTX–
TCNM-AD Barcode Scanner
2 www.bannerengineering.com - tel: 763-544-3164 P/N 175718 Rev. A

TCNM-ACBB1 Terminal Block Connectors
RX 1RX+
CTS 1RX–
SGND SGND SGND
CAUTION: Do not connect GND, SGND, and REF to different (external) ground references. GND, SGND,
and REF are internally connected through filtering circuitry that can be permanently damaged if
subjected to voltage drops over 0.8 Vdc.
25-pin Connector Pinout
The table below gives the pinout of the 25-pin male D-sub connector for connection to the power supply and input/output
signals. Use this pinout when the barcode scanner is connected using the 25-pin connector:
13
2514
1
Figure 2. 25-pin male D-sub connector
25-pin D-sub male connector pinout
Pin Name Function
13, 9 Vdc Power supply input voltage +
25, 7 GND Power supply input voltage –
1 CHASSIS Cable shield connected to chassis
18 I1A External Trigger A (polarity insensitive)
19 I1B External Trigger B (polarity insensitive)
6 I2A Input 2 A (polarity insensitive)
10 I2B Input 2 B (polarity insensitive)
8 O1+ Output 1 +
22 O1– Output 1 –
11 O2+ Output 2 +
12 O2– Output 2 –
20 RX Auxiliary RS232 RX
21 TX Auxiliary RS232 TX
23 ID+ ID-NET™network +
24 ID– ID-NET™network –
14, 15, 16, 17 NC Not Connected
1Do not leave floating, see connection details.
TCNM-AD Barcode Scanner
P/N 175718 Rev. A www.bannerengineering.com - tel: 763-544-3164 3

25-pin D-sub male connector pinout
Pin Name RS232 RS485 Full-Duplex RS485 Half-Duplex
2 INTERFACE TX TX+ RTX+
3 (SW SELECTABLE) RX RX+ 2-
4 RTS TX– RTX–
5 CTS RX– 2-
STEP 2 – Mounting and Positioning the System
1. To mount the barcode scanner, use the mounting bracket to obtain the most suitable position for the reader as
shown in the figures below.
Skew
Tilt
Skew
Pitch
Figure 3. Positioning with mounting bracket
2. When mounting the barcode scanner, take into consideration these three ideal label position angles: Skew 10° to
30°, Tilt 0° and Pitch 0°.
Ensure at least 10° Minimize
Tilt Angle
Minimize
Pitch Angle
S
T
P
Skew Angle
Figure 4. Skew, Tilt, and Pitch Angles
3. Refer to the Reading Diagrams to determine the distance at which your scanner should be positioned.
2Do not leave floating, see connection details.
TCNM-AD Barcode Scanner
4 www.bannerengineering.com - tel: 763-544-3164 P/N 175718 Rev. A

STEP 3 – SMART-TEACH Configuration
SMART-TEACH is the intuitive Human Machine Interface designed to improve ease of installation and maintenance. Status
and diagnostic information are presented using the five colored LEDs, and the single push button gives immediate access
to the following functions:
•AutoLearn—to self-detect and auto-configure for reading unknown
barcodes (by type and length)
•AutoSetup—to self-optimize and auto-configure reading performance
in demanding applications
•Test Mode with bar-graph visualization—to check static reading
performance
SETUP
LEARN
TEST
READY
GOOD
TRIGGER
COM
STATUS
NOTE: If using the TCNM-ACM-OM110 accessory, when entering the SMART-TEACH interface, the
Oscillating Mirror remains in the default fixed position (–15°) to make barcode reading easier while
performing the SMART-TEACH functions.
Table 1: Indicators
Label Color Meaning
READY Green Indicates the device is ready to operate
GOOD Green Confirms successful reading
TRIGGER Yellow Indicates the status of the reading phase
COM Yellow Indicates active communication on main serial port
STATUS Red Indicates a NO READ result
During the reader startup (reset or restart phase), all the LEDs blink for one second.
On the back of the reader near the cable, the “POWER ON” LED indicates the laser scanner is correctly powered.
Auto Learn
If you are configuring your scanner using SMART-TEACH, you must start with the Auto Learn procedure.
1. Hold the SMART-TEACH push button pressed until the LEARN LED is on.
TCNM-AD Barcode Scanner
P/N 175718 Rev. A www.bannerengineering.com - tel: 763-544-3164 5

2. Release the button to enter the Auto Learn function. The reader begins to automatically detect and recognize
barcodes (by type and length) that are presented to it3. The laser turns on and the LEARN LED blinks to indicate
the ongoing process.
SETUP
LEARN
TEST
READY
GOOD
TRIGGER
COM
STATUS
green
green
yellow
yellow
red
1. Place the desired barcode on the scanline.
2. Wait until the LEARN LED is steady ON (indicating the
reader has detected the barcode).
3. Repeat, if needed, the above two steps to program up to
10 different barcodes (the LEARN LED returns to the
blinking state for the next code). If more than one barcode
is detected in the scan line, the Multi Label mode is
enabled (refer to TCNM-AD/EX/SP Family Software
Configuration Parameter Guide help file).
3. Exit the process by pressing the SMART-TEACH push button once. The scanner restarts at the end of the process,
and then the detected barcodes are automatically configured in the scanner memory.
NOTE: If the barcode cannot be read because of low contrast or excessive ambient light, you can
perform the AutoSetup function to optimize the optical parameters. Then you can perform Auto Learn to
recognize the barcode symbology.
NOTE: On exit from Auto Learn, the following parameters are forced: Code Combination = Single Label,
Reading Mode = Linear. If necessary, these parameters can be changed through GeniusPlus.
Auto Setup (Optional)
At the end of the Auto Learn procedure, you may follow the Auto Setup procedure to set up the reading parameters.
1. Hold the SMART-TEACH push button pressed until the SETUP LED is on.
2. Release the button to enter the Auto Setup function.
3. Once entered, if a barcode label is positioned in front of the scanline, the scanner automatically performs the
optimal setup of the reading parameters for that specific barcode.
SETUP
LEARN
TEST
READY
GOOD
TRIGGER
COM
STATUS
green
green
yellow
yellow
red
1. Place the desired barcode on the scanline.
2. Enter the Auto Setup function (the laser turns on and the
SETUP LED blinks to indicate the ongoing process).
3. Wait until the SETUP LED stays steady ON (indicating the
reader has detected the barcode).
This procedure ends either when the barcode is successfully decoded or after a timeout of about 7 seconds. The scanner
restarts at the end of the process, and then the optimized reading parameters for that barcode are automatically
configured in scanner memory.
NOTE: If your application has been configured using SMART-TEACH, go to STEP 5.
Reset Scanner to Factory Default (Optional)
To reset the scanner to the factory default values, hold down the SMART-TEACH push button while powering up the
scanner. At the end of the procedure (about 5–6 seconds), the Configuration and Environmental parameters are reset, and
all LEDs blink simultaneously three times.
3In case of Programming Barcodes, refer to the “Setup Procedure Using Programming Barcodes” document in the product CD.
TCNM-AD Barcode Scanner
6 www.bannerengineering.com - tel: 763-544-3164 P/N 175718 Rev. A

STEP 4 – Installing GeniusPlus Configuration Program
GeniusPlus is a scanner configuration tool that provides several important advantages:
• Wizard approach for new users
• Multi-language version
• Defined configuration directly stored in the reader
• Communication protocol independent from the physical interface allowing to consider the reader as a remote object
to be configured and monitored
To install GeniusPlus, insert the GeniusPlus CD-ROM, wait for the CD to autorun, and follow the installation procedure. The
software is compatible with Windows 98, 2000/NT, XP, Vista, Windows 7, and Windows 8.
This configuration procedure assumes scanner connection to a TCNM-ACBB1. GeniusPlus, running on a laptop computer, is
connected to the scanner auxiliary port through the TCNM-ACBB1 9-pin connector. To communicate with the scanner,
GeniusPlus performs an auto baud rate detection starting from its default parameters, which are 115200, 8, N, 1. These
parameters can also be set in the GeniusPlus Tools > Options > Communications window.
Wizard for Quick Reader Setup
After installing the GeniusPlus software program, the
following window appears asking the user to choose the
desired configuration level.
We advise using the Wizard option for rapid configuration or
new users because it shows a step-by-step scanner
configuration.
1Click Create New to create a new configuration.
TCNM-AD Barcode Scanner
P/N 175718 Rev. A www.bannerengineering.com - tel: 763-544-3164 7

a Select a barcode and drag it into one of the slots at
the bottom. Click Next to configure the selected
barcode(s) on the following screen(s).
bSelect Operating Mode and click Next.
On Line operating mode requires the reader to be
connected to an External Trigger/Presence Sensor
using I1A and I1B inputs.
Automatic operating mode does not require
connection to an external Presence Sensor. When
working in this mode, the reader is continuously
scanning while the reading phase is activated each
time a barcode enters the reader reading zone. The
reader stops reading after an N number of scans
without a code. Barcode characters are transmitted on
the serial interface. In case of a failed reading phase,
no message is sent to the host computer.
cConfigure one or both digital outputs by selecting the
desired Activation Event, Deactivation Event, and
specifying Deactivation Timeout. Click Next.
TCNM-AD Barcode Scanner
8 www.bannerengineering.com - tel: 763-544-3164 P/N 175718 Rev. A

d Select Hardware Interface Type. Click Next.
eSpecify Output Data Format. Click Next.
2After defining the parameter values, the following
window appears allowing you to complete the reader
configuration as follows:
•Save the configuration to disk
• Switch to Advanced Mode
• Send the configuration to the scanner
TCNM-AD Barcode Scanner
P/N 175718 Rev. A www.bannerengineering.com - tel: 763-544-3164 9

3 After sending the configuration to the scanner, click
Next. You have completed the configuration process.
Click Finish.
4After clicking Finish, the System Information
window displays.
STEP 5 – Test Mode
Use a code suitable to your application to test the system.
1. To enter Test Mode, hold down the SMART-TEACH push button until the TEST LED is on.
2. Once entered, the bar graph on the five LEDs is activated and if the scanner starts reading barcodes, the bar graph
shows the Good Read Rate. In case of no-read condition, only the STATUS LED is on and blinking.
SETUP
LEARN
TEST
READY
GOOD
TRIGGER
COM
STATUS
green
green
yellow
yellow
red
TCNM-AD Barcode Scanner
10 www.bannerengineering.com - tel: 763-544-3164 P/N 175718 Rev. A
Other manuals for TCNM-AD
1
Table of contents
Other Banner Barcode Reader manuals

Banner
Banner Barcode Reader P4 BCR User manual

Banner
Banner ABR 7000 Series User manual

Banner
Banner ABR 7000 Series User manual

Banner
Banner ABR7109-MSE2 User manual

Banner
Banner TCNM-AD Manual

Banner
Banner ABR 3000 series User manual

Banner
Banner ABR7109-RSE2 User manual

Banner
Banner ABR Series User manual

Banner
Banner ABR 3000 series User manual

Banner
Banner TCNM AD/EX User manual