AP&T AP-AB1216 User manual

AP&T
R
High Efficient Electroshock-proof
Intelligent Ion Bar
AP-AB1216
Shanghai Anping Static Technology Co.,Ltd
AP&T

Static removal Prevent adhesion of objects Prevent sticking Control ink splashing Prevent uneven scattering
Widely used in electronics, optoelectronics,
semiconductor and other industries
E f f e c t i v e l y s o l v e t h e p r o b l e m c a u s e d b y s t a t i c

High efficient
Safe
Static removal

Intelligent Control
Ion balance /
Ion output frequency adjustable
Positive high voltage amplitude
正高压幅值
Negative high voltage amplitude
time
The negative ion output increases with the
increase of negative high voltage amplitude
The negative ion output increases with the
decrease of negative high voltage amplitude
Adjust ion balance voltage
Vp
Vp Vp
Vp
Vn
Vn Vn
Vn
Adjust the output frequency of
positive and negative high voltage
The output frequency of positive and
negative ions increases
The output frequency of positive
and negative ions decreases
time
-HV
(Negative high voltage)
The output ratio of positive and negative ions is adjustable, which can be used to
adjust the ion balance voltage.
The output frequency of positive and negative ions is adjustable, which can be
applied to different discharge distance to achieve faster discharge speed.
+HV
voltage)(Positive high
Positive voltage working time
Negative voltage working time
-HV
(Negative high voltage)
+HV
(Positive high voltage)
Positive voltage working time
Negative voltage working time
time
-HV
(Negative high voltage)
+HV
(Positive high voltage)
-HV
(Negative high voltage)
+HV
(Positive high voltage)
Positive voltage working time
Negative voltage working time
Positive voltage working time
Negative voltage working time
-HV
(Negative high voltage)
+HV
(Positive high voltage)
-HV
(Negative high voltage)
+HV
(Positive high voltage)
+HV
(Positive high voltage)
+HV
(Positive high voltage)
-HV
(Negative high voltage)
-HV
(Negative high voltage)
Positive high voltage amplitude
Positive high voltage amplitude
Negative high voltage amplitude
Negative high voltage amplitude
Negative high voltage amplitude
Adjust ion balance voltage
time
time time
Adjust the output frequency of
positive and negative high voltage
time time

Intelligent Control
Ion balance /
Ion output frequency adjustable
Button function instructions
Function Symbol Operation instructions
Unlock Unlock before adjusting operating parameters.
Run / Pause Device starts running when power is on. Press "STOP" to standby and no high voltage
output. Press "RUN" again and the device will start working.
Adjust
cleaning cycle CTTH → +/-
Press CTTH first, then +/- to increase or decrease the cleaning cycle. The default cleaning
period is 15 days, and the adjustment range is 1-60 days. The cleaning function will alarm when
the countdown is 0 days. Power off and restart to restore the set time. The cleaning function
becomes invalid if the value is set to 0 days.
Adjust
frequency FREQ → +/- Press FREQ first,then press +/- to increase or decrease the frequency of positive and negative
ions output .
Adjust
ion balance voltage IBN → +/-
Press IBN first, then press + when the positive voltage on flat panel detector or discharge object
surface is high, press IBN first, then press - when the negative voltage on flat panel detector or
discharge object surface is high until the ion balance reaches the ideal status.
Confirm CAL → OK Note: Press CAL first, then press OK to confirm after adjusting the output parameter; otherwise,
false alarms are likely to occur.

Test standard: ANSI/ESD.STM3.1, SJ/T 11446—2013
Test instrument: Trek157 static tester
Test voltage: ±1000V → ±100V attenuation
Test environment: humidity 50±5%; temperature 23±3℃
The test data diagram is as follows (ion bar length: 500mm, Air pressure:0.3Mpa,working frequency: 30Hz):
Stay away static trouble &
for clean production environment
Efficiently static removal
Pulse AC
Comparison with traditional AC
Traditional AC
Pulse AC
Positive pulse Negative pulse
T
Pulse AC Positive voltage working time
Negative voltage working time
+HV
(Positive high pressure)
-HV
(Negative high pressure)
AC
power supplyHigh voltage
Frequency AC
T
Positive voltage working time
Negative voltage working time
+HV
(Positive high pressure)
-HV
(Negative high pressure)
The pulsed AC method alternately applies "+" and "-"
high voltage to one electrode needle to generate two
polar ions.
Compared with the AC method, the ion generation
efficiency is higher.Electrostatic elmiination ability
can be fully plated on matter for short or long
distance.Beside,frequency adjustable so the working
distanceis extended.Positive and negative ion output
ratio adjustable so easy for intelligent control.
Pulse AC
The eect of static eliminating is better
compare to power frequency AC ion bar
Test Length (mm)
Discharge Time(s)
Test Length (mm)
Ion Balance(V)
Test Height (mm)
Test Height (mm)

No.1
No.5
No.3
No.4
No.2
Features
Safe / Easy to use / Durable
Easy installation
Provide stainless steel mounting angle and can adapt
to various installation environments.
Electroshock-proof
Protection against electroshock.
CE certification
It can effectively prevent the external
electromagnetic interference from
affecting the normal operation of the ion
bar. This is a static electricity eliminator
with high safety and high reliability.
Working status visualization
Red light alarm when high voltage abnormal.
Intake throttle valve
The specification is Φ8-G1/8 grey.

Negative high voltage (orange light on when working)
unit:mm
Positive high voltage (green light on when working)
DC
25
3
25
3
16
Φ5
34
25
34
RJ45 port on the front and back panel of ion bar:
The orange light on the front port and the green light on the back port blink alternately with the working frequency;
The green light works at positive high pressure;
The orange light works at negative high pressure.
Product Details
Power input port
Power input port
Compressed air connector
Compressed air connector
Needle holder and electrode needle
Needle holder and electrode needle Strip grounding electrode
Strip grounding electrode
Product Size
Working status indicator
Working status indicator
L=350-3000mm(Needle spacing 50mm)
Ion bar size drawing Mounting bracket size drawing
304 stainless steel
three-combination M5
pan head cross bolt with
flat spring pad
Specification
Details / Parameter / Size

Model AP-AB1216
Input voltage DC 24V
Power 10W
Electrode pin voltage Vpp:8-12KV
Ion emission Pulse AC
Emitter electrode SUS
Discharge structure Resistance coupling
Output frequency 0.1,0.5,1,5,10,30,55,65,105Hz;(EX-Work setting: 30Hz)
Discharge range L*W*H:Bar Length*300*1000mm
Installation distance 100→100mm
Ion balance ≤|±30V|(AV E )
Discharge speed ≤2S (Test distance 300mm)
Status indicator Green light - normal,Blue light - standby,Blue light flashing—debugging /cleaning,Red light - Abnormal high voltage
Working temperature 0℃-50℃
Working humidity <70%
Dimensions(L*W*H) {350-3000mm( Needle spacing 50mm)*35mm*63.5mm
Bar material Flame retardant PVC, AL, SUS
Packaging accessories M5-12*12*4 square nut
Warranty 1 year
CE
Product Parameter
Working temperature 0.6MPa
Working humidity G1/8 for φ8 pipe diameter
Packaging accessories 180°rotatable mounting angle
Power adapter GRT-240200:DC24V 2A dual network port output ;L*W*H:123*61*40.5mm
Certification

12
3
5
+-
OK
CTTH
PWM FREQ CFM
IBV
IBN
123
6
5
4
IBP
CAL ALTH
AP&T
R
Use of the product
Installation step / Installation positon /
Packaging accessories
Installation step
Bracket installation
Adjustable brack
1.Take out the ion bar, adapter power supply, power supply network cable , stainless steel
mounting brackets and other accessories from the packing box.
2.Install the stainless steel mounting brackets on the base mounting slot on the ion bar.
Insert one end of the power cord into the RJ45 socket of the power adapter and the
other end into the power RJ45 socket on the bar body. One adapter can connect up to
two ion bars.
cable
power cable
one adapter for two bars
one adapter for one bar
power cable
cable
cable
Air pipe
Orange light Green light Green light
Front network port Rear network port
1Orange +24VDC
2white-orange +24VDC
3Blue RS485+B
4White-blue RS485+A
5Green 0V
6White-green 0V
7Brown EGND
8white-brown EGND
9Metal shield PE
Power interface definition
Use the remote control to adjust the voltage output parameters under the appropriate
air pressure.When the positive voltage on the surface of the flat panel detector or the
object to be discharged is large, press to adjust "IB-"; when the negative voltage on
the flat panel detector or the surface of the object to be discharged is large, press "IB
+" to adjust until the balance is adjusted to the ideal status.
Connect the air source connector on the bar body to the air source generating device,
turn on the air source switch and control the maximum operating pressure of the
compressed air flow to avoid malfunction of the ion bar.
4
1.The adaptable power indicator light is on and the ion bar panel indicator light is
green to indicate that the ion bar is working.
2.The positive and negative high voltage indicators flash alternately with frequency.
3.The front network port only lights up with orange light-negative high voltage and the
rear network port only lights up with green light-positive high voltage.
Other manuals for AP-AB1216
1
Table of contents
Other AP&T Power Supply manuals

AP&T
AP&T AP-AB1602A User manual

AP&T
AP&T AP-AY1506 User manual

AP&T
AP&T AP-AY1505 User manual

AP&T
AP&T AP-AB1216 User manual

AP&T
AP&T AP-AB1208 User manual

AP&T
AP&T AP-DY6702 User manual

AP&T
AP&T AP-AY450 Series Specification sheet

AP&T
AP&T AP-AY1503 User manual

AP&T
AP&T AP-AY1502 User manual

AP&T
AP&T AP-DC7201 User manual