AP&T AP-AB1208 User manual

AP&T
R
安平静电
High Efficient Electroshock-proof
Intelligent Ion Bar
AP-AB1208
Shanghai Anping Static Technology Co.,Ltd

Widely used in electronics, optoelectronics, semiconductor
and other industries
Prevent sticking
Static removal Prevent adhesion of objects Control ink splashing Prevent uneven scattering
Effectively solve the problem caused by static electricity

Safe
Static removal
High efficient

Intelligent Control
Ion balance/
Ion output frequency adjustable
Positive high voltage amplitude
正高压幅值
Negative high voltage amplitude
time
The negative ion output increases with the
increase of negative high voltage amplitude
The negative ion output increases with the
decrease of negative high voltage amplitude
Adjust ion balance voltage
Vp
Vp Vp
Vp
Vn
Vn Vn
Vn
Adjust the output frequency of
positive and negative high voltage
The output frequency of positive and
negative ions increases
The output frequency of positive
and negative ions decreases
time
-HV
(Negative high voltage)
The output ratio of positive and negative ions is adjustable, which can be used to
adjust the ion balance voltage.
The output frequency of positive and negative ions is adjustable, which can be
applied to different discharge distance to achieve faster discharge speed.
+HV
voltage)(Positive high
Positive voltage working time
Negative voltage working time
-HV
(Negative high voltage)
+HV
(Positive high voltage)
Positive voltage working time
Negative voltage working time
time
-HV
(Negative high voltage)
+HV
(Positive high voltage)
-HV
(Negative high voltage)
+HV
(Positive high voltage)
Positive voltage working time
Negative voltage working time
Positive voltage working time
Negative voltage working time
-HV
(Negative high voltage)
+HV
(Positive high voltage)
-HV
(Negative high voltage)
+HV
(Positive high voltage)
+HV
(Positive high voltage)
+HV
(Positive high voltage)
-HV
(Negative high voltage)
-HV
(Negative high voltage)
Positive high voltage amplitude
Positive high voltage amplitude
Negative high voltage amplitude
Negative high voltage amplitude
Negative high voltage amplitude
Adjust ion balance voltage
time
time time
Adjust the output frequency of
positive and negative high voltage
time time

Intelligent Control
Ion balance/
ion output frequency adjustable
Button function instructions
Function Symbol Operation instructions
Unlock Unlock before adjusting operating parameters.
Run / Pause Device starts running when power is on. Press "STOP" to standby and no high voltage
output. Press "RUN" again and the device will start working.
Adjust
cleaning cycle CTTH → +/-
Press CTTH first, then +/- to increase or decrease the cleaning cycle. The default cleaning
period is 15 days, and the adjustment range is 1-60 days. The cleaning function will alarm when
the countdown is 0 days. Power off and restart to restore the set time. The cleaning function
becomes invalid if the value is set to 0 days.
Adjust
frequency FREQ → +/- Press FREQ first,then press +/- to increase or decrease the frequency of positive and negative
ions output .
Note: this adjustment function can only be effective if the coding switch is in C or D position.
Adjust
ion balance voltage IBN → +/-
Press IBN first, then press + when the positive voltage on flat panel detector or discharge object
surface is high, press IBN first, then press - when the negative voltage on flat panel detector or
discharge object surface is high until the ion balance reaches the ideal status.
Confirm CAL → OK Note: Press CAL first, then press OK to confirm after adjusting the output parameter; otherwise,
false alarms are likely to occur.

Pulse AC
Pulse AC
Comparison with traditional AC
Traditional AC
Pulse AC
Positive pulse Negative pulse
T
Pulse AC Positive voltage working time
Negative voltage working time
+HV
(Positive high pressure)
-HV
(Negative high pressure)
AC
power supplyHigh voltage
Frequency AC
T
Positive voltage working time
Negative voltage working time
+HV
(Positive high pressure)
-HV
(Negative high pressure)
The pulsed AC method alternately applies "+" and "-"
high voltage to one electrode needle to generate two
polar ions.
Compared with the AC method, the ion generation
efficiency is higher.Electrostatic elmiination ability
can be fully plated on matter for short or long
distance.Beside,frequency adjustable so the working
distanceis extended.Positive and negative ion output
ratio adjustable so easy for intelligent control.
Stay away static trouble &
for clean production environment
Test standard: ANSI/ESD.STM3.1, SJ/T 11446—2013
Test instrument: Trek157 static tester
Test voltage: ±1000V → ±100V attenuation
Test environment: humidity 50±5%; temperature 23±3℃
The test data diagram is as follows (ion bar length: 500mm, Air pressure:0.3Mpa,working frequency: 30Hz):
The effect of static eliminating is better
compare to power frequency AC ion bar
Efficiently static removal
Test Length (mm)
Discharge Time(s)
Test Length (mm)
Ion Balance(V)
Test Height (mm)
Test Height (mm)

No.1
No.5
No.4
No.2
Features
Safe / Easy to use / Durable
Electroshock-proof
Protection against electroshock.
Working status visualization
Red light alarm when high voltage abnormal.
CE certification
It can effectively prevent the external
electromagnetic interference from affecting the
normal operation of the ion bar. This is a static
electricity eliminator with high safety and high
reliability.
Easy installation
Provide stainless steel bracket and can adapt to
various installation environments.
No.3
Intake throttle valve
The specification is Φ8-G1/8 grey.

Intake throttle valve
unit:mm
Positive and negative high voltage indicator light (flashing alternately with frequency)
25
3
25
3
16
Φ5
34
25
34
RJ45 port on the front panel of ion bar:
Green light for power on and orange light for communication connection on the left port;
The orange light and the green light on the right port blink alternately with the working frequency;
The green light works at positive high pressure, and the orange light works at negative high pressure.
DC
REM FREQ
Intake throttle valve
Details / Parameter / Size
Specification
Communication and DC24V power network port
Coding switch
Working status indicator
Needle holder and electrode needle Strip grounding electrode
Product Details
Product Size
Coding switch
Working status indicator
Strip grounding electrode
Communication and DC24V power network port Needle holder and electrode needle
L=400mm-3000mm(Needle spacing 50mm)
Ion bar size drawing Mounting bracket size drawing
304 stainless steel
three-combination M5
pan head cross bolt with
flat spring pad
Power indicator
Communication connection instruction

Model AP-AB1208
Input voltage DC 24V
Power 10W
Electrode pin voltage Vpp:8-12KV
Ion emission Pulse AC
Emitter electrode SUS
Discharge structure Resistance coupling
Output frequency 0.1,0.5,1,5,10,30,55,65,105Hz;(EX-Work setting: 30Hz)
Discharge range L*W*H:Bar Length*300*1000mm
Installation distance 100→100mm
Ion balance ≤|±30V|(AV E )
Discharge speed ≤2S (Test distance 300mm)
Status indicator Green light - normal,Blue light - standby,Blue light flashing—debugging /cleaning,Red light - Abnormal high voltage
Working temperature 0℃-50℃
Working humidity <70%
Dimensions(L*W*H) {400-3000mm( Needle spacing 50mm)*35mm*63.5mm
Bar material Flame retardant PVC, AL, SUS
Packaging accessories M5-12*12*4 square nut
Warranty 1 year
CE
Product Parameter
Working temperature 0.6MPa
Working humidity G1/8 for φ8 pipe diameter
Packaging accessories 180°rotatable mounting angle
Power adapter GRT-240200:DC24V 2A dual network port output ;L*W*H:123*61*40.5mm
Certification

Use the remote control to adjust the voltage output parameters under the
appropriate air pressure.When the positive voltage on the surface of the flat
panel detector or the object to be discharged is large, press to adjust "IB-";
when the negative voltage on the flat panel detector or the surface of the
object to be discharged is large, press "IB+" to adjust until the balance is
adjusted to the ideal status.
12
34
5
+-
OK
CTTH
PWM FREQ CFM
IBV
IBN
123
6
5
4
IBP
CAL ALTH
AP&T
R
1.Take out the ion bar, adapter power supply, power supply network cable ,
stainless steel mounting brackets and other accessories from the packing box.
2.Install the stainless steel mounting brackets on the base mounting slot on the
ion bar.
Insert one end of the power cord into the RJ45 socket of the power adapter
and the other end into the power RJ45 socket on the bar body. One adapter
can connect up to two ion bars.
one adapter for one bar
one adapter for two bars
power cable
cable
cable
cable
power cable
Green light
Positive high pressure---Green light
Positive high pressure---Orange light
Air pipe
1Orange +24VDC
2white-orange +24VDC
3Blue RS485+B
4White-blue RS485+A
5Green 0V
6White-green 0V
7Brown EGND
8white-brown EGND
9Metal shield PE
Power interface definition
Connect the air source connector on the bar body to the air source generating
device, turn on the air source switch and control the maximum operating
pressure of the compressed air flow to avoid malfunction of the ion bar.
After power on, the adaptor power indicator light is on and the ion bar
panel indicator light is on. The green color shows that the ion bar is
working normally. The positive and negative high voltage indicator
flashes alternately with frequency.
Installation step
Adjustable brack
Bracket installation
Other manuals for AP-AB1208
1
Table of contents
Other AP&T Power Supply manuals

AP&T
AP&T AP-DY7221 Specification sheet

AP&T
AP&T AP-DC7201 User manual

AP&T
AP&T AP-AB1216 User manual

AP&T
AP&T AP-AY1504 User manual

AP&T
AP&T AP-AY1506 User manual

AP&T
AP&T AP-AY1505 User manual

AP&T
AP&T AP-AB1602A User manual

AP&T
AP&T AP-AY151X Specification sheet

AP&T
AP&T AP-AB1216 User manual

AP&T
AP&T AP-AY1503 User manual






















