AEMC CM605 User manual

AC/DC LOW CURRENT
CLAMP-ON METER
CM605
ENGLISH User Manual

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: 7000.02
Model #: CM605
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.aemc.com

Table of Contents
1. INTRODUCTION............................................................................... 2
1.1 International Electrical Symbols...........................................................3
1.2 Receiving Your Shipment.....................................................................3
1.3 Ordering Information ............................................................................3
2. PRODUCT FEATURES ...................................................................... 4
2.1 Control Features ..................................................................................4
2.2 Display Features ..................................................................................5
2.3 Button Functions ..................................................................................5
2.3.1 HOLD/PEAK Button ...............................................................5
2.3.2 ZERO Button...........................................................................5
3. SPECIFICATIONS............................................................................. 6
3.1 ElectricalSpecications .......................................................................6
3.2 EnvironmentalSpecications...............................................................7
3.3 MechanicalSpecications....................................................................8
3.4 SafetySpecications............................................................................8
4. OPERATION .................................................................................... 9
4.1 Preparation Before Use........................................................................9
4.2 AC Current Measurement ..................................................................10
4.3 DC Current Measurement..................................................................11
4.4 AC Voltage Measurement ..................................................................12
4.5 DC Voltage Measurement..................................................................13
4.6 Resistance Measurement ..................................................................14
4.7 Continuity Test....................................................................................15
4.8 Analog Output ....................................................................................16
5. MAINTENANCE ............................................................................. 17
5.1 Warning .............................................................................................17
5.2 Battery Replacement..........................................................................17
5.3 Cleaning.............................................................................................17
Repair and Calibration........................................................................................18
Technical and Sales Assistance .........................................................................18
Limited Warranty ................................................................................................19
Warranty Repairs................................................................................................19

2
AC Clamp-on Meter Model CM605
CHAPTER 1
INTRODUCTION
Warning
These safety warnings are provided to ensure the safety of personnel
and proper operation of the instrument.
• Readtheinstructionmanualcompletelyandfollowallsafetyinfor-
mation before operating this instrument.
• Onlyuseleads thatcomplywiththe IEC/EN 61010.Beforeusing
them, make sure that they are in safe working order.
• Onlyusefactorysuppliedleads.
• Neverexceedtheprotectionlimitvaluesindicatedinthespecica-
tions for each type of measurement.
• Never measure current while the test leads are connected to the
input jacks.
• Use extreme caution when measuring live systems with voltages
greater than 50VDC or 30VAC.
•
Do not perform resistance or continuity tests on a live circuit.
• Useextremecarewhenworkingaroundbusbarsandbareconduc-
tors.
• Donotusethemeterinoverrange/overloadconditions(OL).
• Whenthemultimeterclampislinkedtothemeasurementcircuits,
do not touch any unused terminals.
• Beforechanging the function, disconnect the measurement leads
from the circuit measured.

AC Clamp-on Meter Model CM605
3
1.1 International Electrical Symbols
This symbol signies that the instrument is protected by double or rein-
forcedinsulation.Useonlyspeciedreplacementpartswhenservicingthe
instrument.
This symbol on the instrument indicates a WARNING and that the
operator must refer to the user manual for instructions before operating
the instrument. In this manual, the symbol preceding instructions indicates
that if the instructions are not followed, bodily injury, installation/sample and
product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol
may be dangerous.
1.2 Receiving Your Shipment
Upon receiving your shipment, make sure that the contents are consistent with the
packing list. Notify your distributor of any missing items. If the equipment appears
tobedamaged,leaclaimimmediatelywiththecarrierandnotifyyourdistributor
at once, giving a detailed description of any damage. Save the damaged packing
container to substantiate your claim. Do not use an instrument that appears to be
damaged.
1.3 Ordering Information
Model CM605 ..................................................................................Cat. #7000.02
Includes clamp-on meter, lead set (red & black lead) with needle point test probes,
carrying case, 2x1.5V AAA batteries and a user manual.

4
AC Clamp-on Meter Model CM605
CHAPTER 2
PRODUCT FEATURES
2.1 Control Features
1.
Tapered jaws for
crowded wiring or areas
(
Ø.45"- 12mm
)
2. Safety barrier
anti-slip guard
3. Lever for jaw
opening/closing
4. LCD display
5.COM(Black)andPositive
(Red)inputterminaljacks
6. Data hold and Peak hold
buttons
7. Rotary range
selector switch
ZERO
OFF
HOLD
PEAK
Press
2 Sec
COM
600V
CAT II
1
2
3
4
6
7
5

AC Clamp-on Meter Model CM605
5
2.2 Display Features
Negative polarity
Auto shutdown
Low battery
AC mode
DC mode
Auto range
Zero(Relative)
Peak function
Hold function
Continuity
A V
Current / Voltage
Ω
Resistance
2.3 Button Functions
2.3.1 HOLD/PEAK Button
Data Hold Function: This function locks the displayed value.
• Toactivate,pressthisbuttonduringthemeasurement.The symbol
appears and the measurement is locked.
• Todeactivate,pressthebuttonagain.
Peak Hold Function: This function displays the peak value.
•To activate, press this button during a measurement until the symbol
appears.
• Thehighestmeasurementisstoredinmemory.
• To deactivate the PEAK function, press and hold down the button for
approximately2seconds.
2.3.2 ZERO Button
• Toactivate,presstheZERO button to enter the Zero mode.
• The symbol will appear and Zero the display.
The reading is stored as a reference value for subsequent measure-
ments.
• ToexittheZeromode,presstheZERO button again.

6
AC Clamp-on Meter Model CM605
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
Reference Conditions: Accuracy given @ 23°C ± 5°C, 80% RH Max, Conductor centered in jaws, 45-65Hz, No
DC Component.
AC Current ( )
Range Resolution Accuracy Frequency
10A 1mA 2.0% R ± 10cts
50 to 500Hz
100A 10mA 80A: 2.0% R ± 10cts
>80A: 3.5% R ± 10cts
DC Current ( ) - Positive only*
Range Resolution Accuracy
10A 1mA 2.5% R ± 10cts
100A 10mA 80A: 2.5% R ± 10cts
>80A: 4.5% R ± 10cts
AC Volts ( )
Range Resolution Accuracy Impedance Frequency
600V 100mV 1.5% R ± 5cts 10MΩ, <50pF 40 to 500Hz
Overload Protection: 660Vrms
DC Volts ( ) - Positive only*
Range Resolution Accuracy Input Impedance
600V 100mV 1.0% R ± 2cts 10MΩ
Overload Protection: 660Vrms
* For negative measurement, add 2cts to the accuracy

AC Clamp-on Meter Model CM605
7
Resistance (Ω)
Range Resolution Accuracy Test Voltage Protection
10kΩ (9999Ω)1Ω1.0% R ± 3cts <3.0VDC 600Vrms
Continuity ( )
Buzzer Resolution Test Voltage Protection
<100Ω± 25Ω1Ω<3.0VDC 600Vrms
Analog Output
Range Output Frequency Output Impedance
AAC & ADC 10mV/A through
front banana jacks 0 to 20kHz @ ± 3db 3kΩ, <50pF
Digital display: 10,000-count4digitLCDdisplay(9999max)
Polarity:
When a negative signal is applied, the symbol appears.
Overload:
Iftherangeisexceeded,the symbol is displayed.
Low Battery Indicator:
is displayed when the voltage supplied by the batteries is lower than the operat-
ing voltage.
Power Supply:
2batteries-1.5VtypeAAA(LR03)
Auto-off:
Automaticshutdownafterapprox10minutewithover-ride
Sampling:
Approx2measurements/second
3.2 Environmental Specifications
Operating Temperature:
32°to104°F(0°to40°C),<80%RHmaxnon-condensing
Storage Temperature:
14°to140°F(-10°to60°C),<70%RHmaxnon-condensing
Altitude: 6000ft(2000m)

8
AC Clamp-on Meter Model CM605
3.3 Mechanical Specifications
Maximum Cable Diameter:
Ø0.45"(12mm)
Maximum Jaw Opening:
Ø0.60"(15mm)
Dimensions:
7.44x2.80x1.46"(189x71x37mm)
Weight:
6.5oz(180g)
3.4 Safety Specifications
IEC/EN 61010-1, 600V CAT II, 300V CAT III
- Insulation: Class II
- Pollution Degree: 2
Table of contents
Other AEMC Test Equipment manuals

AEMC
AEMC MN261 User manual

AEMC
AEMC pmr-1 User manual

AEMC
AEMC FlexProbe 24-3001 User manual

AEMC
AEMC 6416 Installation and operating instructions

AEMC
AEMC 6418 User manual

AEMC
AEMC SR601 User manual

AEMC
AEMC SR652 User manual

AEMC
AEMC SR751 User manual

AEMC
AEMC 4620 User manual

AEMC
AEMC OX III Series User manual