Adtec RD-60 User manual

RD-60
Multi-CODEC Receiver / Decoder
Includes demodulator versions - ADV, LB, TD and PRM
U ER GUIDE
02.01.2015 - v1.13.00

Contents
Contents
Trademarks & Copyrights
Electrical Device Compliance Notices
Safety Warnings and Cautions
Compliance Notices
FCC
Industry Canada
European nion EMC Directive Conformance Statement
Chapter 1 - Product Introduction
Covered Equipment
Front Panel
Front Panel LCD
Transport LED Indicators
Audio Decode Indicators
System Indicators
Controls
Reset
Front Panel Menu Structure
Services Menu
RF Rx Menu ( ADV Advanced / PRM Premium )
RF Rx Menu ( LB L - Band )
IP Rx Menu
Video Menu
Audio Menu
VBI Menu
CAS Menu
System Menu
Login
Duration
Network
Time
NTP
Alarm
SNMP Menu
Com 2
Host Name
Firmware
Feature Menu
Back Panel
DB 9- M Analog audio output pinout
COM 1/ COM 2 to DB 9 serial adapter pinout
GPIO and Parport information
GPIO pinout

Parport pinout
Chapter 2 - Getting Connected
Introduction to the Control Application
Compatible browsers
Ethernet Access
Zero Configuration Access
Login
Firmware pgrade via Web ser Interface
Demodulator Firmware pgrade via Web ser Interface
pgrading Via FTP & Telnet
In Field Feature pgrades
Permanent Key Instructions
Temporary Key Instructions
Feature Key Descriptions
Chapter 3 - Operational How - Tos
DVB - S / DVB - S 2 A TO Modes ( ADV and PRM )
DVB - S / DVB - S 2 A TO Modes ( LB option )
DVB - S 2 - Recommended use of Pilots
How to use RF Profiles ( LB option )
DP / RTP / FEC / TCP IP Rx
Multicast Reception - Address
nicast Reception - Address
nicast / Multicast Reception
Dolby E , Dolby D , LPCM , and Mpeg 1 Layer 2
AFD - Active Format Description
Genlock System
TS Out Decrypt
Chapter 4 - Appendix
Appendix A - GN General Public License
Appendix B - Technical Specifications
Base Model ( RD 60-09)
Inputs
Outputs
Communications
Video and Audio
Physical and Operational
Premium Demodulator ( PRM option )
Advanced Demodulator ( ADV option )
L - Band Demodulator ( LB option )
Standard Demodulator ( STD option , discontinued )
Appendix C - Adtec Digital Support & Service
Telephone and Email Support
Preparing for Support
SLA Options

Trademarks & Copyrights
Copyright: (c) 2011-13 Adtec Digital. All rights reserved. This document may not, in whole
or in part, be copied, photocopied, reproduced and translated, or reduced to any electronic
medium or machine-readable form without prior written consent from Adtec Digital.
Trademarks: RD-60 is a trademark of Adtec Digital. Dolby, Dolby Digital, AC-3 and the
double-D symbol are registered trademarks of Dolby Laboratories. Other product and
company names may be trademarks or registered trademarks of their respective companies.
The information in this document is subject to change without notice.

Electrical Device Compliance
Notices
Safety Warnings and Cautions
For your safety and the proper operation of the device:
● This unit must be installed and serviced by suitably qualified personnel only.
● Do not break the warranty seals on the device or open the lid. Only approved service
technicians are permitted to service this equipment.
● Disconnect all power before servicing the unit.
● Do not expose this device to rain or other moisture. Clean only with a dry cloth.
● If not installed in an equipment rack, install the product securely on a stable surface.
● Install the product in a protected location where no one can step or trip over the
supply cord, and where the supply cord will not be damaged.
● If a system is installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than the room ambient
temperature.
● Consideration should be given to installing the unit in an environment compatible
with the maximum recommended ambient temperature of 50 degrees Celsius (122
degrees Fahrenheit).
● Install the unit in a rack so that the amount of airflow required for safe operation is
not compromised.
○ The recommended clearance on the top and sides of the unit is at least ½ “
(one half inch/one centimeter).
● Mounting of the unit in a rack should be such that no hazardous condition is achieved
due to uneven mechanical loading.
● se only a grounded electrical outlet when connecting the unit to a power source.
● Reliable earth grounding of rack-mount equipment should be maintained.
○ Particular attention should be given to supply connection other than direct
connections to the branch circuit (e.g., use of power strips).
Compliance Notices
FCC
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio

communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications to this device not expressly approved by Adtec Digital
could void the user’s authority to operate the equipment.
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference
Causing Equipment Regulations. Operation is subject to the following two conditions:(1) this
device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence
canadienne causant des règlements d'équipement. L'opération est sujette aux deux
conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce
dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut
causer l'opération peu désirée.
European Union EMC Directive Conformance Statement
This product is in conformity with the protection requirements of E Council Directive
2004/108/EC on the approximation of the laws of the Member States relating to
electromagnetic compatibility. Adtec Digital cannot accept responsibility for any failure to
satisfy the protection requirements resulting from a user modification of the product. This
product has been tested and found to comply with the limits for Class B Information
Technology Equipment according to CISPR 22 / EN 55022.

Chapter 1 Product Introduction
Covered Equipment
RD-60: MPEG 4 / MPEG 2 Capable IRD. Transport Stream inputs standard on ALL RD
models include ASI and GigE. Video outputs standard on ALL models include Composite and
HD-SDI (x4 Bank A and B). Standard audio decode includes two (2) Dolby E pass-through
and four (4) stereo pairs (8 mono) of MPEG 1 Layer 2 with an optional upper 4 stereo pairs
(8 stereo pairs or 16 mono channels). BISS 1 / E decryption included. Includes Genlock &
Redundant AC power supplies. Optional DVBS/S2 demodulator packages available.
**VERSION 06 and HIGHER DOES NOT S PPORT HDMI O TP T**
RD-60 w/ tandard Demodulator (RD60-XX-DMOD- TD): RD60 (as configured above)
+ Standard Demodulator. Supports L-Band, DVB-S/S2, QPSK 1 - 45 Mbaud and 8PSK 1 - 30
Mbaud.
RD-60 w/ L-Band Demodulator (RD60-XX-DMOD-LB): RD60 (as configured above) +
LB Demodulator. Supports L-Band, DVB-S 1 - 62 Mbaud, DVB-S2 1 - 65 Mbaud.
* Software Key field upgradeable to high symbol rate (>30Msym/s), 16APSK, and 32APSK.
RD-60 w/ Advanced Demodulator (RD60-XX-DMOD-ADV): RD60 (as configured
above) + Advanced Demodulator which adds 7072 Newtec Demodulator. Supports L-Band,
DVB-S 1 - 30 Mbaud, DVB-S2 1 - 30 Mbaud.
* Software Key field upgradeable to 16APSK.
RD-60 w/ Premium Demodulator (RD60-XX-DMOD-PRM): RD60 (as configured above)
+ Premium Demodulator which adds 7044 Newtec Demodulator. Supports L-Band, DVB-
S/S2, QPSK/8PSK 256kbaud - 45Mbaud*. nit is CCT capable* ( 5%, 10%, and 15% roll-
off ).
* Software Key field upgradeable to 16APSK, 32APSK, and 45 Mbaud. CCT capability may
require software update for older demodulators.
Front Panel
The front panel LCD and keypad can be used to configure and monitor your device.

Front Panel LCD
1) Feedback tate: There are several quick view menu screens available when in regular
feedback state. You can view any of these quick view status screens by using the up and
down arrow buttons.

2) Disabled Product tate: When the product is in a disabled state, the LCD will relay the
following information. This state is generally only used when a factory restore is performed.
If that is the case, note that all of the configurations have been returned to factory defaults
including Network configurations. To reapply network configurations simply press the Down
arrow when in this state to navigate through the network menu.
Transport LED Indicators
Indicator Function
Decode Off - Decoder is idle.
On - Decoder is active.
ASI / IP /RF Off - No services detected on the input.
On - Services detected on the input.
Lock 1 / Lock 2 Off - Tuner is not locked
On - Tuner is locked
IP Out Off - IP Egress is idle.
On - IP Egress is active.
* IP Output is not applicable for RD-60 products
Bars Off - All B/T/ID options are disabled.
On - B/T/ID options are enabled.
Audio Decode Indicators
Indicator Function
A1 through A8 Off - Audio engine is not active.
On - Audio engine is actively decoding or performing pass-through.
Blinking - Audio engine is in a failure mode ( no pass-through or audio
decoding )

System Indicators
Indicator Function
Alarm Off - No system alarms.
On - System alarm.
(NTP or FAN alarm)
BISS Off - Decryption configuration is turned OFF
On - Decryption configuration is set to BISS1 or BISSE
Link Off - Network communication link not detected
On - Network communication link detected
Busy Off - No network activity
On - Network traffic present
Controls
sing the Mode, elect, Enter, Escape, and directional buttons, the user can control the
unit via the front panel.
Control Function
Mode button Mode will cycle through top layer menus.
Select Select will enter into edit mode.
Enter Enter submits any edited configurations.
Escape Escape returns to the previous menu layer.
Cursor Arrows Arrows will navigate you within submenus
Programming
Keypad
For value entry. F1 functions as a “+” or “-” operator. F2 functions
as a “.” decimal or period.
Reset
Should you need to reset your device, you can do so via the front panel by pressing the MODE,
ESCAPE and RI HT ARROW keys simultaneously.
Table of contents
Other Adtec Media Converter manuals

Adtec
Adtec Edje-2000 User manual

Adtec
Adtec EN-31 User manual

Adtec
Adtec EN-91 User manual

Adtec
Adtec EN-30 User manual

Adtec
Adtec EN-80 User manual

Adtec
Adtec RD-71 User manual

Adtec
Adtec RD-70 User manual

Adtec
Adtec mediaHUB-HD Pro User manual

Adtec
Adtec mediaHUB Pro User manual

Adtec
Adtec EN-200 User manual

Adtec
Adtec mediaHUB-HD 422 User manual

Adtec
Adtec EN-20 User manual

Adtec
Adtec EN-210 User manual

Adtec
Adtec mediaHUB-HD 422 User manual

Adtec
Adtec Edje 4000 User manual

Adtec
Adtec EN-31 User manual

Adtec
Adtec EN-81 User manual

Adtec
Adtec Duet User manual

Adtec
Adtec RD-71 User manual

Adtec
Adtec edje 5110 User manual