Adtec EN-200 User manual

EN-200
1080p AVC Low Latency Encoder
Includes modulator version - IF/LB/10M
USER GUIDE
3.00.29

Table of Contents
Table of Contents
Trademarks & Copyrights
Electrical Device Compliance Notices
Safety Warnings and Cautions
Compliance Notices
FCC
Industry Canada
European Union EMC Directive Conformance Statement
Chapter 1 - Getting Started
Front Panel
Front Panel LCD Quick Views
Transport LED Indicators
Audio Encode Indicators
System Indicators
Controls
Modulator Lineup
Front Panel Menu Structure
1. Services Menu
2. RF Tx Menu
3. IP Tx Menu
4. Video Menu
5. Audio Menu
6. PIDs Menu
7. VBI Menu
8. Profile Menu
9. CAS Menu
10. System Menu
10.1 Login
10.2 Duration
10.3 Network Sub Menu
10.4 Time Sub Menu
10.5 NTP Sub Menu
10.6 Alarm Menu
10.7 SNMP Sub Menu
10.8 Com2 Settings
10.9 Feature Sub Menu
10.10 Host Name
10.11 Firmware
10.12 Backlight Dim Delay
Back Panel
GPIO and Parport information
GPIO Pinout
Parport Pinout

Chapter 3 - Getting Connected
Compatible browsers
Ethernet Access
Zero Configuration Access
Login
Upgrading Via Web User Interface
Upgrading Via FTP & Telnet
Chapter 4 - Operational How-To’s
How to Use Vertical Interval Time Code
How to Configure Passthru Audio
Understanding Auto Transport Mux Rate
How to Use ASI-Receive Mode
How to Use ASI Remux
EN-XX ASI Remux with Manual PID Mapping
How to setup a Zixi IP stream on the Adtec Encoders
Chapter 5 - Appendix
Appendix A - GNU General Public License
Appendix B - Technical Specifications
Base Model (EN200)
Inputs
Outputs
Communications
Video
Audio
Physical and Operational
IF, L-Band Modulator + 10MHz
Appendix C - DB15-M Analog audio input pinout:
Appendix D - Adtec Digital Support & Service
Telephone and Email Support
Preparing for Support
SLA Options

Trademarks & Copyrights
Copyright: (c) 2016 Adtec Digital. All rights reserved. This document may not, in whole or
in part, be copied, photocopied, reproduced and translated, or reduced to any electronic
medium or machine-readable form without prior written consent from Adtec Digital.
Trademarks: EN-200 is a trademark of Adtec Digital. Dolby, Dolby Digital, AC-3 and the
double-D symbol are registered trademarks of Dolby Laboratories. Other product and
company names may be trademarks or registered trademarks of their respective
companies. The information in this document is subject to change without notice.

Electrical Device Compliance Notices
Safety Warnings and Cautions
For your safety and the proper operation of the device:
●This unit must be installed and serviced by suitably qualified personnel only.
●Do not break the warranty seals on the device or open the lid. Only approved service
technicians are permitted to service this equipment.
●Disconnect all power before servicing the unit.
●Do not expose this device to rain or other moisture. Clean only with a dry cloth.
●If not installed in an equipment rack, install the product securely on a stable surface.
●Install the product in a protected location where no one can step or trip over the
supply cord, and where the supply cord will not be damaged.
●If a system is installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than the room ambient
temperature.
●Consideration should be given to installing the unit in an environment compatible
with the maximum recommended ambient temperature of 50 degrees Celsius (122
degrees Fahrenheit).
●Install the unit in a rack so that the amount of airflow required for safe operation is
not compromised.
○The recommended clearance on the top and sides of the unit is at least ½ “
(one half inch/one centimeter).
●Mounting of the unit in a rack should be such that no hazardous condition is achieved
due to uneven mechanical loading.
●Use only a grounded electrical outlet when connecting the unit to a power source.
●Reliable earth grounding of rack-mount equipment should be maintained.
○Particular attention should be given to supply connection other than direct
connections to the branch circuit (e.g., use of power strips).
Compliance Notices
FCC
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
●Reorient or relocate the receiving antenna.
●Increase the separation between the equipment and receiver.

●Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
●Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications to this device not expressly approved by Adtec Digital
could void the user’s authority to operate the equipment.
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference Causing
Equipment Regulations. Operation is subject to the following two conditions:(1) this device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence
canadienne causant des règlements d'équipement. L'opération est sujette aux deux
conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce
dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut
causer l'opération peu désirée.
European Union EMC Directive Conformance Statement
This product is in conformity with the protection requirements of EU Council Directive
2004/108/EC on the approximation of the laws of the Member States relating to
electromagnetic compatibility. Adtec Digital cannot accept responsibility for any failure to
satisfy the protection requirements resulting from a user modification of the product. This
product has been tested and found to comply with the limits for Class B Information
Technology Equipment according to CISPR 22 / EN 55022.

Chapter 1 - Getting Started
Front Panel
The Function Buttons and Directional Keypad of the EN-200 are used to configure and
monitor the signal input and output of the device.
Front Panel LCD Quick Views
There are several Quick Views that can be accessed via the front panel LCD by
pressing the up and down arrows.
1) Service Data: When in normal encoding mode, the LCD will display the following
information: TS Mux Rate, Conditional Access Mode, Service ID Number, Service Name, and
Service Provider.
2) Encoding Status: This quick view displays the Input and Output Resolution, Frame
Rate, Input interface, SDI interface Mode, and Bars/Tones/ID status.
3) Video Status: This quick view displays the Video PID, PCR PID, Chroma Type, Latency,
Video Bitrate, Entropy Coding, and Video Autofill status.

4) Audio Status: This quick view displays the Audio Codec type, Encode or Pass Through
Rate, Encode or Passthrough mode.
5) Audio PIDS: This quick view displays the Audio PIDs for all 8 pairs of audio.
6) TSoIP State: This quick view displays the status of IP Transport mode, RTP, FEC mode,
and Multicast Connector. Up to 4 destination IP addresses can be sent simultaneously.
7) Modulator State*: This quick view displays the RF Tx status if the unit is equipped with
optional modulator.
8) ASI Remux State: This quick view displays the status of ASI Remux status if the
feature is enabled.

Transport LED Indicators
Indicator
Function
Video
Off - If modulator is installed, an off led indicates that no video is detected on
the selected input or that ASI Receive mode is enabled.
On - Video is detected on the selected input.
Blink - No video is detected and fault mode is active.
Encode
Off - Device is not encoding. Idle State
On - Device is encoding.
3/2/1F
Off - Low, Normal, or Long Latency
On - 3 Frame, 2 Frame, or 1 Frame Latency (Requires Adtec RD-7x Decoder)
4:2:2
Off - Encoding chroma type 4:2:0.
On - Encoding chroma type 4:2:2.
Remux
Off - ASI Remux is disabled
On - ASI Remux is enabled
IP Out
Off - Transport stream over IP via IP1 or IP2 is inactive.
On - Transport stream over IP via IP1 or IP2 is active.
RF Out
Off - Modulator is not transmitting.
On - Modulator is transmitting.
Blink - Modulator is running in test mode (pure carrier).
Note: Making changes to specific modulator parameters can cause the
modulator to stop transmitting and you will need to re-enable it. This is by
design to prevent transmission with an incorrect power setting.
RTMP
Off - Over The Top RTMP transmission not enabled
On - Over The Top RTMP transmission enabled
Audio Encode Indicators
Indicator
Function
A1 through
A8
Off - Audio encoder configuration is set to off.
On - Audio encoder configuration is set to encode or passthru.
Note: This product offers optional extended audio encoding of the upper
four pairs. If you experience issues engaging the upper pairs, check your
feature keys first.

System Indicators
Indicator
Function
Alarm
Off - No system alarms.
On - System alarm.
(Typically NTP alarm)
BISS
Off - Service is not encrypted “Clear - Free to air”
On - Service is Encrypted “Cyphed - Selected BISS mode”
Link
Off - No network detected
On - Network communication active
Busy
Off - No network activity
On - Network traffic present
Controls
Using the Mode, Select, Enter, Escape, and directional buttons, the user can control the unit
via the front panel.
Control
Function
Mode button
Mode will cycle you through top layer menus.
Select
Select will enter you into edit mode.
Enter
Enter submits any edits.
Escape
Escape returns you to the previous menu layer.
Cursor Arrows
Arrows will navigate you within submenus
Programming
Keypad
For value entry. F2 functions as a “.” decimal or period.
Table of contents
Other Adtec Media Converter manuals

Adtec
Adtec edje 5110 User manual

Adtec
Adtec EN-31 User manual

Adtec
Adtec mediaHUB Pro User manual

Adtec
Adtec mediaHUB-HD 422 User manual

Adtec
Adtec EN-80 User manual

Adtec
Adtec RD-71 User manual

Adtec
Adtec mediaHUB-HD 422 User manual

Adtec
Adtec Edje-2000 User manual

Adtec
Adtec EN-30 User manual

Adtec
Adtec EN-20 User manual




























