Abus SHBW10000 User manual

2
English
Introduction
Dear customer,
We are pleased that you have chosen our product and thank you for your trust! You made a good
choice.
This 4in1 Sensor (hereinafter referred to as the "device") has been developed and manufactured with
the utmost care. Please read these operating instructions completely and observe all operating and
safety instructions, as this ensures the best possible handling of the device. This document is an
installation and maintenance manual.
If you have any questions, please contact your specialist trade partner
or contact our customer service:
Mail: ABUS Support, Linker Kreuthweg 5, 86444 Affing, Germany
E-mail: support@abus-sc.com
Phone: +49 8207 959 90 888
Hotline opening hours: Mon-Thu: 08 - 17 h; Fri: 08 - 14 h
ABUS Security-Center hereby declares that the enclosed product comply with the requirements
of the following directives
RED Directive (2014/53/EU), EMC Directive (2014/30/EU), Low Voltage Directive (2014/35/EU) and
RoHS Directive (2011/65/EU). The full EU Declaration of Conformity text can be found at:
www.abus.com/product/SHBW10000
It can also be obtained at the following adress:
ABUS Security-Center GmbH & Co. KG,
Linker Kreuthweg 5, 86444 Affing, GERMANY
All contained company names and product designations are trademarks of the respective owners. All
rights reserved.
Disclaimer of Liability
These operating instructions have been prepared with the greatest care. Should you nevertheless
notice omissions or inaccuracies, please inform us in writing at the above address.
Your rights are limited to the repair or replacement of this product as delivered. ABUS Security Center
assumes no liability for any special, incidental or consequential damages, including but not limited to
loss of revenue, loss of profit, restrictions in the use of the software, loss or recovery of data, costs
for replacement equipment, downtime, property damage and claims of third parties, as a result of and
in connection with the use of the software.a. warranty, contractual, legal or claims for damages
notwithstanding other limited or implied warranty provisions or in the event that the limited warranty
does not apply, the scope of liability of ABUS Security Center is limited to the purchase price of the
product.
The contents of this manual are subject to change without notice.
© ABUS Security-Center GmbH & Co. KG, 09/2018

3
English
Important Safety Informations
Intended Use
Only use the device for the purpose for which it was built and designed. Any other use is considered
unintended.
All guarantee claims are invalid in the event of damage caused by non-compliance with this
safety information. We cannot be held liable for resulting damage.
Unboxing
Handle the device with extreme care when unpacking it.
Packaging and packaging aids can be reused and, as far as possible, should be sent for recycling.
If the original packaging has been damaged, inspect the device first. If the device shows signs
of damage, return it in the original packaging and inform the delivery service.
Please ensure that the package also contains the DSK (Z-Wave Device Specific
Key) – Card. This card shows the DSK of your ABUS Z-Wave Multisensor. Please
keep it in a safe place. Any S2 (Security 2) certified Z-Wave Gateway will require
this DSK to program your sensor.
Installation location / operating environment
Do not place any heavy objects on the device. The device is only designed for operation in spaces with
appropriate temperatures or humidity (e.g. not for bathrooms). Do also not place the device in areas
with excessive accumulation of dust. Please refer to the individual devices' technical data for more
detailed information. Ensure that: adequate ventilation is always guaranteed; no direct sources of heat
can affect the device; interior devices are not exposed to direct sunlight or strong artificial light; the
device is not in the immediate vicinity of magnetic fields (e.g. loudspeakers); no naked flames (e.g. lit
candles) are placed on or next to the device; sprayed or dripping water is prevented from coming into
contact with interior devices and caustic fluids are avoided; the device is not operated in the vicinity of
water, in particular, the device should never be submerged (do not place objects containing fluids, e.g.
vases or drinks, on or near the device); no foreign bodies penetrate the device; the device is not
exposed to wide temperature variations, as otherwise there maybe condensation from humidity causing
electrical short circuits; the device is not exposed to excessive shock or vibration.
Children
Keep electrical devices out of reach of children. Never allow children to use electrical devices
unsupervised. Children may not always properly identify possible hazards. Small parts may be fatal if
swallowed. Keep packaging film away from children. There is a risk of suffocation. This device is not
intended for children. If used incorrectly, parts under spring tension may fly out and cause injury to
children (e.g. to eyes).

4
English
Information on handling batteries
Make sure that batteries are kept away from small children. Children may put batteries in their
mouths and swallow them. This can cause serious harm to their health. If this happens, consult
a doctor immediately.
Do not charge normal batteries, heat them up or throw them into naked flames (they may
explode).
The battery must not be directly exposed to heat or sunlight, and must not be stored in a place
with a very high temperature.
The battery must not come into contact with water.
The battery must not be dismantled, pierced or otherwise damaged.
The battery contacts must not be short-circuited.
Change low batteries in good time.
Always change all the batteries at the same time and use batteries of the same type.
Leaky or damaged batteries can cause chemical burns on contact with the skin. In this case,
wear protective gloves. Clean the battery compartment with a dry cloth.
Important information on battery disposal
Batteries with this label do not contain harmful substances such as cadmium, lead and
mercury. However, used batteries must not be disposed of along with household waste
in accordance with the battery directive. To protect natural resources and promote the
recycling of materials, separate the batteries from other waste and deposit them at a
local recycling center. An additional label with the chemical symbols for Hg, Cd or Pb
means that the batteries contain quantities of mercury, cadmium or lead which exceed
the restrictions set by the EU Directive 2006/66/EG. If batteries are not disposed of
properly, these substances can cause harm to human health or the environment
Cleaning
Dusty devices must be cleaned. You can clean dust from the air vents using a vacuum cleaner
or compressed air. If necessary, you can remove the dust with a brush.
You can clean the surface using a cloth slightly dampened in soapy water. Only use suitable
microfiber cloths for high-gloss surfaces.
Do not allow water to penetrate the device.
Do not clean the device in a dishwasher.
Do not use sharp, pointed, abrasive or corrosive cleaning materials or hard brushes.
Do not use chemicals.
Do not use flammable liquids for cleaning the device.
Information on device disposal
Important: The EU Directive 2012/19/EU regulates the proper return, treatment and
recycling of used electronic devices. This symbol means that in the interest of
environmental protection the device must be disposed of separately from household or
industrial waste at the end of its service life in accordance with applicable local legal
guidelines. Disposing of used devices can be done at official recycling centers in your
country. Obey local regulations when disposing of material. Further details on returns
(also for non-European countries) can be obtained at your local authority. Separate
collection and recycling saves natural resources and ensures that all the provisions for protecting health
and environment are observed when recycling the product.

5
English
Table of contents
1. Product introduction ......................................................................................................................... 6
1.1. Scope of Delivery..................................................................................................................... 6
1.2. Device features........................................................................................................................ 6
1.3. Operating principle .................................................................................................................. 6
1.4. Performance Features............................................................................................................. 7
1.5. Use in systems of different manufacturers.............................................................................. 7
2. Overview of functions....................................................................................................................... 8
2.1. Inclusion / Add Device............................................................................................................. 8
2.2. Mounting & Installation ............................................................................................................ 9
2.3. Exclusion / Remove Device................................................................................................... 10
2.4. Reset (Factory-Reset) ........................................................................................................... 10
2.5. Wake-up ................................................................................................................................ 11
3. Advanced Z-Wave Parameter........................................................................................................ 11
3.1. Association Group Information.............................................................................................. 11
3.2. Overview Configuration Parameter ....................................................................................... 12
3.3. Command Classes ................................................................................................................ 14
4. Technical Specifications................................................................................................................. 15

6
English
1. Product introduction
1.1. Scope of Delivery
ABUS Z-Wave Multisensor including Battery
Quickguide & Safety instructions
Screws & dowels
1.2. Device features
Nr Label Comment
1 LED Indicator Status displayed for various processes (inclusion, exclusion, reset)
2 Network-Button For inclusion / exclusion of the detector in a gateway, factory reset
3 Mounting Plate For wall-mounting
1.3. Operating principle
The SHBW10000 was developed for use in home automation systems that use the Z-Wave wireless
standard. The multisensor has the following sensors:
PIR
temperature
atmospheric humidity
lights
The motion sensor lets you know when something moves within a certain range and can then trigger
various scenes/actions. The device also reports the current room temperature, humidity and
illuminance.
In conjunction with configurable scenes, smart functions can also be initiated in addition to monitoring,
e.g. if temperature <20 degrees, heating on.

7
English
1.4. Performance Features
The ABUS Z-Wave SHBW10000...:
…is a battery-operated 4in1-Multisensor
…is Z-Wave PLUS compatible & certified
…supports the Z-Wave S2 Standard (Security 2)
…detects/measures motion/PIR, brightness, temperature and humidity
…has a recognition range of max. 5 meters
...has a battery-empty warning function
…was developed for indoor installation
1.5. Use in systems of different manufacturers
Communication is via the Z-Wave EU frequency (868.42 Mhz). You can integrate the device into any
Z-Wave network with a certified Z-Wave gateway, regardless of manufacturer. All non-battery powered
nodes in the network act as repeater to increase the durability of the network.

8
English
2. Overview of functions
2.1. Inclusion / Add Device
Click the + (Add) button in your Z-Wave App and follow
the further instructions
Press the Button on the device once.
The App will show if the Add device process was
successful. The Status LED will light up for 2 seconds.
Repeat the inclusion process if it was not successful.

9
English
2.2. Mounting & Installation
Test the release behaviour at the desired mounting
position in advance.
Installation site:
Optimum detection at an installation height of 180-240
cm.
Remove the safety strip from the battery compartment.
Fix the Mounting plate on the wall by screws
(recommended) or adhesive tape. Screw the detector
onto the mounting plate and ensure that the two holes
on the housing point downwards.
Note:
Do not mount the detector…
…opposite heat sources or windows
…less than 1m away from power or gas lines
…near electronic or wireless devices
…above heaters
…next to the floor
…near large metal structures

10
English
2.3. Exclusion / Remove Device
Click the - (Remove) button in your Z-Wave App and
follow the further instructions
Press the Button on the device once.
The App will show if the Remove device process was
successful.
Repeat the exclusion process if it was not successful.
2.4. Reset (Factory-Reset)
Keep pressing the Button on the device for more than
5 seconds (the flash interval of the Status LED is now
accelerated)
The device is now restored to factory settings
Note:
This procedure should only be used if the primary
gateway is not capable of acting.
If the device is set to the factory setting, the status is
set to "not included", the association settings and
possible configurations are reset to default.
Other manuals for SHBW10000
1
Table of contents
Other Abus Accessories manuals

Abus
Abus GB3010 W User manual

Abus
Abus TVAC71070 User manual

Abus
Abus SHHA10000 User manual

Abus
Abus FUMK35000A User manual

Abus
Abus FUMK35000A User manual

Abus
Abus FU8350 User manual

Abus
Abus PLMK10000 User manual

Abus
Abus PROFILINE MEGA LED Series User manual

Abus
Abus FUSG35010A User manual

Abus
Abus FUMK50031 Manual