Applicable Place
Suitable for indoor air disinfection in public places,families and other place which
people can stay in the same room when machine power on.
Installation&Use Of Environment
1.Connect one end of power cord to the power connector on the back of the mac-
hine,please use the applicable power supply voltage in accordance with this pro-
duct,then press the leakage protector switch,please stay away from heaters,
stoves or other heat sources.
1.
Please do not use explosive or volatile chemicals near the machine.If machine
inhales these chemicals,it may cause fire or explosion.
2.
Please leave at least 20 cm of space around the machine and put it in a suitable
place indoors.
Function &Use Introduction
When turning on the sterilization function,please be sure to turn on the fan at the
same time to increase the circulating air volume,can effectively improve the steriliz-
ation effect.Manually touch the on/offkey,
machine will be turned on,touch the wind
speed key,the fan starts to run,touch the sterilize key,the UV lamp starts to work,
the system will continue to start the sterilization work,touch the sterilize key again,
the UV lamp will be turned off,the sterilization function stops.
Principles of sterilization,killing microorganism types
This machine has a built-in single-ended ultraviolet lamp,which uses ultraviolet
as the main sterilization factor,and uses circulating air to disinfect indoor air to
kill bacteria in the air.The air outlet is equipped with a high-efficiency filter device,
which can effectively prevent the entry of bacteria.
Killing microorganism types:staphylococcus albicans.
-09--02-
*1.The voltage and frequency are based on the standard of the country or region in
which they are used.The actual use of parameters please based on the product sticker!
*2.The test data identified are laboratory data.If there is any discrepancy,please refer
to the physical test data.
Daily Maintenance
1.When the machine works for about 2000 hours.please clean the air filter,use a
brush to remove the dust on the filter
and put it back,to ensure sufficient air volume.
2.For better maintenance and maintenance,please check carefully whether the
disinfection device,circulating air device,air filter device,electric control device,
etc are working properly aperiodically,otherwise replace it timely.
3.
If the machine is shut down for a long time,the power should be cut off and
covered with a clean cloth.
Check item How to check Frequency
external wiring visually check for looseness 3 months
Centrifugal fan
and motor
the centrifugal fan must rotate smoothly without
generating abnormal sound.If abnormal sound is
heard,please confirm whether there is foreign
matter in the blower and whether the noise of the
motor bearing is abnormal.If the motor has
problems,please replace it.
12 months
Pre filter to check whether the surface is damaged;cleaned
every 3 months 3 months
UV lamp to check the lamp tube every six months for damage 6 months
Important Safety Instructions
Please read the manual carefully before using,to avoid personal injury and
property damage.When installing the product,
the product power plug must be
inserted into a power supply that may be grounded.
Please use the applicable power supply
voltage in accordance with this product,
otherwise it will cause damage or fire to the product.
Please keep good hygienic conditions,and can not store flammable and explo-
sive materials around,otherwise it will affect the purification effect and the risk
of fire or explosion.
Please protect the product with both hands
when it is
moving,
to
prevent
it from
tilting or falling,causing personal injury.
The machine should be maintained regularly and irregularly,otherwise it will
affect the purification effect and have hidden dangers.Maintenance should be
carried out under the condition of shutdown and power off to avoid the risk of
electric shock.
This manual has been carefully checked, if there are any
printing or binding error, please feel free to contact us。
-08-
-03-